CoChat

Trapped-ion cell with improved dc potential harmonicity for FT-ICR MS

Open access
Tolmachev, Aleksey V., Robinson, Errol W., Wu, Si, Kang, Hyuk, Lourette, Natacha M., Paša-Tolić, Ljiljana, Smith, Richard D. · 2008 · Journal of the American Society for Mass Spectrometry
Cited by 108

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The trapped-ion cell is a key component critical for optimal performance in Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS). To extend the performance of FT-ICR MS, we have developed a new cell design that is capable of generating a DC trapping potential which closely approaches that of an ideal Penning trap, i.e., a 3D axial quadrupolar potential distribution. The new cell design was built upon an open cylindrical geometry, supplemented with two pairs of cylindrical compensation segments. Electric potential calculations for trial cell geometries were aimed at minimizing spatial variations of the radial electric field divided by radius. The resulting cell proportions and compensation voltages delivered practically constant effective ion cyclotron frequency that was independent of ion radial and axial positions. Our customized 12 tesla FT-ICR instrument was upgraded with the new cell, and the performance was characterized for a range of ion excitation power and ion populations. Operating the compensated cell at increased postexcitation radii, approximately 0.7 of the cell inner radius, resulted in improved mass measurement accuracy together with increased signal intensity. Under these same operating conditions the noncompensated open cell configuration exhibited peak splitting and reduced signal life time. Mass accuracy tests using 11 calibrants covering a wide m/z range reproducibly produced under 0.05 ppm RMS precision of the internal calibration for reduced ion populations and the optimal excitation radius. Conditions of increased ion population resulted in a twofold improvement in mass accuracy compared with the noncompensated cell, due to the larger achievable excitation radii and correspondingly lower space charge related perturbations of the calibration law.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jasms.2008.01.006

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 108

Metadata

Authors
Tolmachev, A. V., Robinson, E. W., Wu, S., Kang, H., Lourette, N. M., Paša-Tolić, L., & Smith, R. D.
Venue
Journal of the American Society for Mass Spectrometry
Published
2008-04-01
Volume
19
Issue
4
Pages
586-597
ISSN
1044-0305 (ISSN-L)
OpenAlex
W1965018389
Cited by
108
References
4
FWCI
4.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trapped-ion cell with improved dc potential harmonicity for FT-ICR MS. https://app.cochat.ai/papers/10.1016/j.jasms.2008.01.006
The paper
Tolmachev, A. V., Robinson, E. W., Wu, S., Kang, H., Lourette, N. M., Paša-Tolić, L., & Smith, R. D. (2008). Trapped-ion cell with improved dc potential harmonicity for FT-ICR MS. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2008.01.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.