Trapped-ion cell with improved dc potential harmonicity for FT-ICR MS
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The trapped-ion cell is a key component critical for optimal performance in Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS). To extend the performance of FT-ICR MS, we have developed a new cell design that is capable of generating a DC trapping potential which closely approaches that of an ideal Penning trap, i.e., a 3D axial quadrupolar potential distribution. The new cell design was built upon an open cylindrical geometry, supplemented with two pairs of cylindrical compensation segments. Electric potential calculations for trial cell geometries were aimed at minimizing spatial variations of the radial electric field divided by radius. The resulting cell proportions and compensation voltages delivered practically constant effective ion cyclotron frequency that was independent of ion radial and axial positions. Our customized 12 tesla FT-ICR instrument was upgraded with the new cell, and the performance was characterized for a range of ion excitation power and ion populations. Operating the compensated cell at increased postexcitation radii, approximately 0.7 of the cell inner radius, resulted in improved mass measurement accuracy together with increased signal intensity. Under these same operating conditions the noncompensated open cell configuration exhibited peak splitting and reduced signal life time. Mass accuracy tests using 11 calibrants covering a wide m/z range reproducibly produced under 0.05 ppm RMS precision of the internal calibration for reduced ion populations and the optimal excitation radius. Conditions of increased ion population resulted in a twofold improvement in mass accuracy compared with the noncompensated cell, due to the larger achievable excitation radii and correspondingly lower space charge related perturbations of the calibration law.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955 · cited 1×
“A number of reviews describe the general features of FT-ICR MS and the milestones of its historical evolution, as well as the current rapid expansion of its use in biomolecule analysis and, in particular, proteomics [2-8].”
BackgroundOpen-endcap Penning traps for high precision experiments
Gabrielse, G., Haarsma, L., & Rolston, S. L. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85027-x · Cited by 288 · cited 1×
“Their study demonstrated that by adding the compensation electrodes to the open cylindrical cell, anharmonicities of the trapping potential could be tuned out, thus enabling the high precision measurements [17].”
BackgroundGabrielse, G. (1983) · Physical Review A · doi:10.1103/physreva.27.2277 · Cited by 97 · cited 3×
“It is well recognized that deviations from the ideal quadrupolar DC potential, which is characteristic for such cell geometries, impose deleterious effects on FT-ICR measurements and various approaches to the cell anharmonicity problem have been explored [14-27].”
BackgroundHigh mass resolution with a new variable anharmonicity Penning trap
Van Dyck, R. S., Wineland, D. J., Ekstrom, P. A., & Dehmelt, H. G. (1976) · Applied Physics Letters · doi:10.1063/1.88793 · Cited by 87
Cited by
21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures
Smith, D. F., Podgorski, D. C., Rodgers, R. P., Blakney, G. T., & Hendrickson, C. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04159 · Cited by 348
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Predator data station: A fast data acquisition system for advanced FT-ICR MS experiments
Blakney, G. T., Hendrickson, C. L., & Marshall, A. G. (2011) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2011.03.009 · Cited by 261
Savory, J. J., Kaiser, N. K., McKenna, A. M., Xian, F., Blakney, G. T., Rodgers, R. P., Hendrickson, C. L., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac102943z · Cited by 255
40 years of Fourier transform ion cyclotron resonance mass spectrometry
Marshall, A. G., & Chen, T. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2014.06.034 · Cited by 70
“Seven-section cylindrical (left) [31] and dynamically harmonized (right) [32] ion traps for FT-ICR MS.”
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Metadata
- Authors
- Tolmachev, A. V., Robinson, E. W., Wu, S., Kang, H., Lourette, N. M., Paša-Tolić, L., & Smith, R. D.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-04-01
- Volume
- 19
- Issue
- 4
- Pages
- 586-597
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1965018389
- Cited by
- 108
- References
- 4
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.