Resolving the composition of protein complexes using a MALDI LTQ orbitrap
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Current biological studies have been advanced by the continuous development of robust, accurate, and sensitive mass spectrometric technologies. The MALDI LTQ Orbitrap is a new addition to the Orbitrap configurations, known for their high resolving power and accuracy. This configuration provides features inherent to the MALDI source, such as reduced spectra complexity, forgiveness to contaminants, and sample retention for follow-up analyses with targeted or hypothesis-driven questions. Here we investigate its performance for characterizing the composition of isolated protein complexes. To facilitate the assessment, we selected two well characterized complexes from Saccharomyces cerevisiae, Apl1 and Nup84. Manual and automatic MS and MS/MS analyses readily resolved their compositions, with increased confidence of protein identification compared with our previous reports using MALDI QqTOF and MALDI IT. CID fragmentation of singly-charged peptides provided sufficient information for conclusive identification of the isolated proteins. We then assessed the resolution, accuracy, and sensitivity provided by this instrument in the context of analyzing the isolated protein assemblies. Our analysis of complex mixtures of singly-charged ions up to m/z 4000 showed that (1) the resolving power, inversely proportional to the square root of m/z, had over four orders of magnitude dynamic range; (2) internal calibration led to improved accuracy, with an average absolute mass error of 0.5 ppm and a distribution centered at 0 ppm; and (3) subfemtomole sensitivity was achieved using both CHCA and DHB matrices. Additionally, our analyses of a synthetic phosphorylated peptide in mixtures showed subfemtomole level of detection using neutral loss scanning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Douglas, C. M., Foor, F., Marrinan, J. A., Morin, N., Nielsen, J. B., Dahl, A. M., Mazur, P., Baginsky, W., Li, W., & el-Sherbeini, M. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.26.12907 · Cited by 401
Fluorescent Proteins as Proteomic Probes
Cristea, I. M., Williams, R., Chait, B. T., & Rout, M. P. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500227-mcp200 · Cited by 251
Self-citationTracking and Elucidating Alphavirus-Host Protein Interactions
Cristea, I. M., Carroll, J.-W. N., Rout, M. P., Rice, C. M., Chait, B. T., & MacDonald, M. R. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m603980200 · Cited by 192 · cited 1×
“noaffinity purifications [28] and two-step isolations”
Self-citationI-DIRT, A General Method for Distinguishing between Specific and Nonspecific Protein Interactions
Tackett, A. J., DeGrasse, J. A., Sekedat, M. D., Oeffinger, M., Rout, M. P., & Chait, B. T. (2005) · Journal of Proteome Research · doi:10.1021/pr050225e · Cited by 131 · cited 3×
“Supplementary Table S4 presents a complete list of the identified proteins, classified according to their affiliation to structural subunits of the nuclear pore complex, or proteins that we and others [25, 44] have observed as common contaminants in isolations from yeast cell extracts.”
Cited by
Distinct Factors Control Histone Variant H3.3 Localization at Specific Genomic Regions
Goldberg, A. D., Banaszynski, L. A., Noh, K.-M., Lewis, P. W., Elsaesser, S. J., Stadler, S., Dewell, S., Law, M., Guo, X., Li, X., et al. (2010) · Cell · doi:10.1016/j.cell.2010.01.003 · Cited by 1,280
Self-citationLi, T., Diner, B. A., Chen, J., & Cristea, I. M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1203447109 · Cited by 297
“MS/MS data were searched by SEQUEST in Proteome Discoverer (ThermoFisher Scientific) against a human protein database (SwissProt) and common contaminants, plus reversed sequences (21,569 entries).”
Self-citationCristea, I. M., Moorman, N. J., Terhune, S. S., Cuevas, C. D., O'Keefe, E. S., Rout, M. P., Chait, B. T., & Shenk, T. (2010) · Journal of Virology · doi:10.1128/jvi.00139-10 · Cited by 155
“LTQ Orbitrap (Thermo, Bremen, Germany) as described previously (52).”
Self-citationMiteva, Y. V., Budayeva, H. G., & Cristea, I. M. (2013) · Analytical Chemistry · doi:10.1021/ac3033257 · Cited by 105
Self-citationMoorman, N. J., Sharon-Friling, R., Shenk, T., & Cristea, I. M. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900485-mcp200 · Cited by 97
Self-citation
Metadata
- Authors
- Luo, Y., Li, T., Yu, F., Kramer, T., & Cristea, I. M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-01
- Volume
- 21
- Issue
- 1
- Pages
- 34-46
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2071299018
- Cited by
- 38
- References
- 5
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resolving the composition of protein complexes using a MALDI LTQ orbitrap. https://app.cochat.ai/papers/10.1016/j.jasms.2009.08.026
- The paper
- Luo, Y., Li, T., Yu, F., Kramer, T., & Cristea, I. M. (2010). Resolving the composition of protein complexes using a MALDI LTQ orbitrap. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2009.08.026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.