Evaluation and selection of open-source EMR software packages based on integrated AHP and TOPSIS
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Evaluating and selecting software packages that meet the requirements of an organization are difficult aspects of software engineering process. Selecting the wrong open-source EMR software package can be costly and may adversely affect business processes and functioning of the organization. This study aims to evaluate and select open-source EMR software packages based on multi-criteria decision-making. A hands-on study was performed and a set of open-source EMR software packages were implemented locally on separate virtual machines to examine the systems more closely. Several measures as evaluation basis were specified, and the systems were selected based a set of metric outcomes using Integrated Analytic Hierarchy Process (AHP) and TOPSIS. The experimental results showed that GNUmed and OpenEMR software can provide better basis on ranking score records than other open-source EMR software packages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Decision making with the analytic hierarchy process
Saaty, T. L. (2008) · International Journal of Services Sciences · doi:10.1504/ijssci.2008.017590 · Cited by 10,301 · cited 3×
“Saaty in [53] described the following steps to apply AHP:”
BackgroundMethodInfluential(1993) · Cited by 9,879
Multiple attribute decision making : an introduction
Yoon, K., & Hwang, C. L. (1995) · Sage eBooks · Cited by 1,356
NIELSEN, J. (1993) · Usability Engineering · doi:10.1016/b978-0-08-052029-2.50009-7 · Cited by 934
Software for Use: A Practical Guide to the Models and Methods of Usage-Centered Design
Constantine, L. L. (1999) · Cited by 930
Security and privacy in electronic health records: a systematic literature review.
Fernández-Alemán, J. L., Señor, I. C., Lozoya, P. Á. O., & Toval, A. (2013) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2012.12.003 · Cited by 675 · cited 1×
“Access control, HIPAA compliance, and security of communication and data exchange are adopted from [46], based on security and privacy categories identified in the ISO 27799 standard [47].”
MethodUsability measurement and metrics: A consolidated model
Seffah, A., Donyaee, M., Kline, R. B., & Padda, H. K. (2006) · Software Quality Journal · doi:10.1007/s11219-006-7600-8 · Cited by 648 · cited 1×
“Finally, the subjective feeling of ease and convenience experienced by the user, as well as his impression of the user interface would gauge the satisfaction factor [27].”
BackgroundUsability—context, framework, definition, design and evaluation
Shackel, B. (1991) · Cambridge University Press eBooks · Cited by 399
Evaluating and selecting software packages: A review
Jadhav, A. S., & Sonar, R. M. (2009) · Information and Software Technology · doi:10.1016/j.infsof.2008.09.003 · Cited by 249 · cited 3×
“MCDM aims to help decision makers select the best alternative, sort out potential alternatives among the available options, and rank the alternatives in decreasing order of their performance [4,5].”
BackgroundUsing quality models in software package selection
Franch, X., & Carvallo, J. P. (2003) · IEEE Software · doi:10.1109/ms.2003.1159027 · Cited by 247
Cited by
Albahri, O. S., Zaidan, A. A., Albahri, A. S., Zaidan, B. B., Abdulkareem, K. H., Al-qaysi, Z. T., Alamoodi, A. H., Aleesa, A. M., Chyad, M. A., Alesa, R. M., et al. (2020) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2020.06.028 · Cited by 275
Self-citationA Systematic Review of the Applications of Multi-Criteria Decision Aid Methods (1977–2022)
Basílio, M. P., Pereira, V., Costa, H. G., Santos, M., & Ghosh, A. (2022) · Electronics · doi:10.3390/electronics11111720 · Cited by 218
Mardani, A., Hooker, R. E., Ozkul, S., Yifan, S., Nilashi, M., Sabzi, H. Z., & Fei, G. C. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.07.002 · Cited by 208
Mohammed, K. I., Zaidan, A. A., Zaidan, B. B., Albahri, O. S., Alsalem, M. A., Albahri, A. S., Hadi, A., & Hashim, M. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1362-x · Cited by 171
Self-citationRundo, L., Pirrone, R., Vitabile, S., Sala, E., & Gambino, O. (2020) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2020.103479 · Cited by 113
Mohsin, A. H., Zaidan, A. A., Zaidan, B. B., Albahri, O. S., Albahri, A. S., Alsalem, M. A., & Mohammed, K. I. (2019) · Computer Standards & Interfaces · doi:10.1016/j.csi.2019.04.002 · Cited by 89
Self-citation
Metadata
- Authors
- Zaidan, A. A., Zaidan, B. B., Al-Haiqi, A., Kiah, M. L. M., Hussain, M., & Abdulnabi, M.
- Venue
- Journal of Biomedical Informatics
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 53
- Pages
- 390-404
- ISSN
- 1532-0464 (ISSN-L)
- OpenAlex
- W2076120051
- Cited by
- 184
- References
- 38
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.