The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Characterization of the mechanical properties of skin by inverse analysis combined with the indentation test
Abstract
This study proposes a new method to determine the mechanical properties of human skin by the use of the indentation test [Pailler-Mattei, 2004. Caractérisation mécanique et tribologique de la peau humaine in vivo, Ph.D. Thesis, ECL-no. 2004-31; Pailler-Mattei, Zahouani, 2004. Journal of Adhesion Science and Technology 18, 1739-1758]. The principle of the measurements consists in applying an in vivo compressive stress [Zhang et al., 1994. Proceedings of the Institution of Mechanical Engineers 208, 217-222; Bosboom et al., 2001. Journal of Biomechanics 34, 1365-1368; Oomens et al., 1984. Selected Proceedings of Meetings of European Society of Biomechanics, pp. 227-232; Oomens et al., 1987. Journal of Biomechanics 20(9), 877-885] on the skin tissue of an individual's forearm. These measurements show an increase in the normal contact force as a function of the indentation depth. The interpretation of such results usually requires a long and tedious phenomenological study. We propose a new method to determine the mechanical parameters which control the response of skin tissue. This method is threefold: experimental, numerical, and comparative. It consists combining experimental results with a numerical finite elements model in order to find out the required parameters. This process uses a scheme of extended Kalman filters (EKF) [Gu et al., 2003. Materials Science and Engineering A345, 223-233; Nakamura et al., 2000. Acta Mater 48, 4293-4306; Leustean and Rosu, 2003. Certifying Kal…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, working collagen I concentrations at physiological levels[59,62,63] do not recapitulate the mechanical properties of the native ECM[64–66].”
Citations
Cites
Viscoelastic properties of human skin and processed dermis
Silver, F. H., Freeman, J. W., & DeVore, D. P. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.007001018.x · Cited by 480
Holzapfel, G. A. (2001) · Elsevier eBooks · doi:10.1016/b978-012443341-0/50107-1 · Cited by 421
Determination of properties of graded materials by inverse analysis and instrumented indentation
Nakamura, T., Wang, T. W. T., & Sampath, S. (2000) · Acta Materialia · doi:10.1016/s1359-6454(00)00217-2 · Cited by 251
A mixture approach to the mechanics of skin
Oomens, C. W. J., van Campen, D. H., & Grootenboer, H. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90147-3 · Cited by 195
Model of the viscoelastic behaviour of skin in vivo and study of anisotropy
Khatyr, F., Imberdis, C., Vescovo, P., Varchon, D., & Lagarde, J. (2004) · Skin Research and Technology · doi:10.1111/j.1600-0846.2004.00057.x · Cited by 189
Self-citationPassive transverse mechanical properties of skeletal muscle under in vivo compression
Bosboom, E. M., Hesselink, M. K. C., Oomens, C. W. J., Bouten, C. V. C., Drost, M. R., & Baaijens, F. F. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00083-5 · Cited by 179
Micro-indentation and inverse analysis to characterize elastic–plastic graded materials
Gu, Y. X., Nakamura, T., Prchlík, L., Sampath, S., & Wallace, J. S. (2003) · Materials Science and Engineering A · doi:10.1016/s0921-5093(02)00462-8 · Cited by 116
Measurement of the friction coefficient of the human skin in vivo
Asserin, J., Zahouani, H., Humbert, P., Couturaud, V., & Mougin, D. (2000) · Colloids and Surfaces B Biointerfaces · doi:10.1016/s0927-7765(99)00169-1 · Cited by 98
Self-citationStudy of adhesion forces and mechanical properties of human skin in vivo
Pailler-Mattei, C., & Zahouani, H. (2004) · Journal of Adhesion Science and Technology · doi:10.1163/1568561042708368 · Cited by 87
Self-citationThe Reaction of Skin and Soft Tissue to Shear Forces Applied Externally to the Skin Surface
Zhang, M., Turner-Smith, A. R., & Roberts, V. C. (1994) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1994_208_291_02 · Cited by 51
Nonlinear model of skin mechanical behaviour analysis with finite element method
Guicheret-Retel, V., Vescovo, P., Jacquet, E., Trivaudey, F., Varchon, D., & Burtheret, A. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.70302.x · Cited by 49
Experimental and Theoretical Compression Studies on Porcine Skin
Oomens, C. W. J., van Campen, D. H., Grootenboer, H. J., & Boer, L. J. D. (1985) · Springer eBooks · doi:10.1007/978-94-011-7432-9_29 · Cited by 15
Mechanical Properties of the Skin During Friction Assessment
Elsner, P., Berardesca, E., & Wilhelm, K.-P. (2001) · CRC Press eBooks · doi:10.1201/b14261-8 · Cited by 1
Research works printed but not linked: 1
- Pailler-Mattei, C., 2004. Caractérisation mécanique et tribologique de la peau humaine in vivo, PhD. Thesis. ECL-no. 2004-31.
Cited by
Sorted by citations
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
Self-citationSkin mechanical properties and modeling: A review
Joodaki, H., & Panzer, M. B. (2018) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411918759801 · Cited by 482
Non-Fourier analysis of skin biothermomechanics
Xu, F., Seffen, K. A., & Lu, T. J. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2007.10.024 · Cited by 376
Biothermomechanics of skin tissues
Xu, F., Lu, T. J., & Seffen, K. A. (2007) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2007.11.011 · Cited by 234
Zahouani, H., Pailler-Mattei, C., Sohm, B., Vargiolu, R., Cenizo, V., & Debret, R. (2008) · Skin Research and Technology · doi:10.1111/j.1600-0846.2008.00329.x · Cited by 209
Self-citation
Metadata
- Authors
- Delalleau, A., Josse, G., Lagarde, J.-M., Zahouani, H., & Bergheau, J.-M.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Institut de Recherche Pierre Fabre (France) (FR)
- Corresponding author
- Delalleau, Alexandre
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2006
- Volume
- 39
- Issue
- 9
- Pages
- 1603-1610
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2083717009
- Cited by
- 230
- References
- 13
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 4 · 2023: 10 · 2022: 7 · 2021: 15 · 2020: 8 · 2019: 15 · 2018: 10 · 2017: 14 · 2016: 8 · 2015: 20 · 2014: 11 · 2013: 9 · 2012: 13
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Physical Sciences › Engineering › Computational Mechanics › Contact Mechanics and Variational Inequalities
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- skin biomechanics, indentation testing, inverse analysis, extended Kalman filter, finite element analysis, contact force, skin stiffness, parameter estimation, forearm skin, contact mechanics, viscoelasticity, hyperelasticity, contact pressure distribution, skin viscoelasticity, skin hyperelasticity
- MeSH terms
- Biomechanical Phenomena, Humans, Skin Physiological Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review