The DOI matches its Crossref record.
Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows
Abstract
Blood flow in the circle of Willis (CoW) is modelled using the 1-D equations of pressure and flow wave propagation in compliant vessels. The model starts at the left ventricle and includes the largest arteries that supply the CoW. Based on published physiological data, it is able to capture the main features of pulse wave propagation along the aorta, at the brachiocephalic bifurcation and throughout the cerebral arteries. The collateral ability of the complete CoW and its most frequent anatomical variations is studied in normal conditions and after occlusion of a carotid or vertebral artery (VA). Our results suggest that the system does not require collateral pathways through the communicating arteries to adequately perfuse the brain of normal subjects. The communicating arteries become important in cases of missing or occluded vessels, the anterior communicating artery (ACoA) being a more critical collateral pathway than the posterior communicating arteries (PCoAs) if an internal carotid artery (ICA) is occluded. Occlusions of the VAs proved to be far less critical than occlusions of the ICAs. The worst scenario in terms of reduction in the mean cerebral outflows is a CoW without the first segment of an anterior cerebral artery combined with an occlusion of the contralateral ICA. Furthermore, in patients without any severe occlusion of a carotid or VA, the direction of flow measured at the communicating arteries corresponds to the side of the CoW with an absent or occluded artery. Finally, we study the effect of partial occlusions of the communicating arteries on the cerebral flows, which again confirms that the ACoA is a more important collateral pathway than the PCoAs if an ICA is occluded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Collateral blood vessels in acute ischaemic stroke: a potential therapeutic target
Shuaib, A., Butcher, K., Mohammad, A. A., Saqqur, M., & Liebeskind, D. S. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70195-8 · Cited by 508
Hemodynamics of Cerebral Aneurysms
Sforza, D. M., Putman, C. M., & Cebral, J. R. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102126 · Cited by 466
Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.05.041 · Cited by 441
Self-citationChoudhari, P., & Panse, M. S. (2016) · Procedia Computer Science · doi:10.1016/j.procs.2016.07.277 · Cited by 28
Metadata
- Authors
- Alastruey, J., Parker, K. H., Peiró, J., Byrd, S. M., & Sherwin, S. J.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2007
- Volume
- 40
- Issue
- 8
- Pages
- 1794-1805
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2172213190
- Cited by
- 436
- References
- 0
- FWCI
- 12.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows. https://app.cochat.ai/papers/10.1016/j.jbiomech.2006.07.008
- The paper
- Alastruey, J., Parker, K. H., Peiró, J., Byrd, S. M., & Sherwin, S. J. (2007). Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2006.07.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.