Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Computational models may have the ability to quantify the relationship between hip morphology, cartilage mechanics and osteoarthritis. Most models have assumed the hip joint to be a perfect ball and socket joint and have neglected deformation at the interface between bone/cartilage. The objective of this study was to analyze finite element (FE) models of hip cartilage mechanics with varying degrees of simplified geometry and a model with a rigid bone material assumption to elucidate the effects on predictions of cartilage stress. A previously validated subject-specific FE model of a cadaveric hip joint was used as the basis for the models. Geometry for the bone/cartilage interface was either: 1) subject-specific (i.e. irregular), 2) spherical, or 3) a rotational conchoid. Cartilage was assigned either a varying (irregular) or constant thickness (smoothed). Loading conditions simulated walking, stair climbing and descending stairs. FE predictions of contact stress for the simplified models were compared with predictions from the subject-specific model. Both spheres and conchoids provided a good approximation of native hip joint geometry (average fitting error ~0.5 mm). However, models with spherical/conchoid bone geometry and smoothed articulating cartilage surfaces grossly underestimated peak and average contact pressures (50% and 25% lower, respectively) and overestimated contact area when compared to the subject-specific FE model. Models incorporating subject-specific bone geometry with smoothed articulating cartilage also underestimated pressures and predicted evenly distributed patterns of contact. The model with rigid bones predicted much higher pressures than the subject-specific model with deformable bones. The results demonstrate that simplifications to the geometry of the bone/cartilage interface, cartilage surface and bone material properties can have a dramatic effect on the predicted magnitude and distribution of cartilage contact pressures in the hip joint.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiplier and gradient methods
Hestenes, M. R. (1969) · Journal of Optimization Theory and Applications · doi:10.1007/bf00927673 · Cited by 2,446 · cited 1×
“Incompressibility was enforced using the augmented Lagrangian method (Hestenes, 1969).”
Hip contact forces and gait patterns from routine activities
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00040-9 · Cited by 2,215 · cited 4×
“Loads and geometric orientation of the femur relative to the acetabulum were prescribed based on published data for in-vivo hip loads (Bergmann, 1998; Bergmann et al., 2001).”
InfluentialBeck, M., Kalhor, M., Leunig, M., & Ganz, R. (2005) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.87b7.15203 · Cited by 1,988 · cited 2×
“, dysplasia and femoroacetabular impingement) are the underlying cause of hip OA (Cooperman et al., 1983; Harris, 1986; Michaeli et al., 1997; Reynolds et al., 1999; Mavcic et al., 2002; Murphy et al., 2004; Beck et al., 2005; Kim et al., 2006).”
The Etiology of Osteoarthritis of the Hip: An Integrated Mechanical Concept
Ganz, R., Leunig, M., Leunig-Ganz, K., & Harris, W. H. (2008) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-007-0060-z · Cited by 1,620 · cited 2×
“, dysplasia and femoroacetabular impingement) are the underlying cause of hip OA (Cooperman et al., 1983; Harris, 1986; Michaeli et al., 1997; Reynolds et al., 1999; Mavcic et al., 2002; Murphy et al., 2004; Beck et al., 2005; Kim et al., 2006).”
Retroversion of the acetabulum: A CAUSE OF HIP PAIN
Reynolds, D., Lucas, J., & Klaue, K. (1999) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.81b2.0810281 · Cited by 880
Etiology of Osteoarthritis of the Hip
HARRIS, W. H. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198612000-00004 · Cited by 677
An in vitro investigation of the acetabular labral seal in hip joint mechanics
Ferguson, S. J., Bryant, J. T., Ganz, R., & Ito, K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00365-2 · Cited by 629 · cited 2×
“Data from in-vitro studies suggests fluid flow is minimal during fast loading (Macirowski et al., 1994; Ferguson et al., 2003) and the instantaneous response of an incompressible hyperelastic material has been shown to be equivalent to the response of a biphasic material under fast loading conditions (Ateshian et al.”
Acetabular Dysplasia in the Adult
Cooperman, D. R., Wallensten, R., & Stulberg, S. D. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198305000-00013 · Cited by 495 · cited 2×
“…it has been hypothesized that morphological abnormalities (i.e., dysplasia and femoroacetabular impingement) are the underlying cause of hip OA (Cooperman et al., 1983; Harris, 1986; Michaeli et al., 1997; Reynolds et al., 1999; Mavcic et al., 2002; Murphy et al., 2004; Beck et al., 2005; Kim…”
Ferguson, S. J., Bryant, J. T., Ganz, R., & Ito, K. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00042-7 · Cited by 455 · cited 1×
“Substantial research efforts have been directed at developing constitutive equations for both bone (e.g. orthotropic behavior (Pistoia et al., 2001)) and cartilage (e.g. poroelasticity (Ferguson et al., 2000; Li et al., 2003)).”
Whirley, R. G., & Engelmann, B. E. (1993) · doi:10.2172/10139227 · Cited by 395
Cited by
Finite element prediction of cartilage contact stresses in normal human hips
Harris, M. D., Anderson, A. E., Henak, C. R., Ellis, B. J., Peters, C. L., & Weiss, J. A. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.22040 · Cited by 212
“A previous computational study investigated how contact stresses were altered when femoral and acetabular geometry were changed from subject-specific to an ideal sphere.(33) Models with ideal geometry had substantially reduced cartilage contact stresses and more uniform distributions of contact.”
Self-citationPatient-specific analysis of cartilage and labrum mechanics in human hips with acetabular dysplasia
Henak, C. R., Abraham, C. L., Anderson, A. E., Maas, S. A., Ellis, B. J., Peters, C. L., & Weiss, J. A. (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.11.003 · Cited by 172
Self-citationNg, K. C. G., Lamontagne, M., Labrosse, M. R., & Beaulé, P. E. (2016) · PLoS ONE · doi:10.1371/journal.pone.0147813 · Cited by 54
“Although the inclusion of a labrum in FEA remains elusive [32], it would be beneficial in future studies to understand the residual physiological effect of the labral seal for this patholog-”
Influential
Metadata
- Authors
- Anderson, A. E., Ellis, B. J., Maas, S. A., & Weiss, J. A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 43
- Issue
- 7
- Pages
- 1351-1357
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2139151236
- Cited by
- 197
- References
- 39
- FWCI
- 15.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.