Finite element prediction of cartilage contact stresses in normal human hips
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Our objectives were to determine cartilage contact stress during walking, stair climbing, and descending stairs in a well‐defined group of normal volunteers and to assess variations in contact stress and area among subjects and across loading scenarios. Ten volunteers without history of hip pain or disease with normal lateral center‐edge angle and acetabular index were selected. Computed tomography imaging with contrast was performed on one hip. Bone and cartilage surfaces were segmented from volumetric image data, and subject‐specific finite element models were constructed and analyzed using a validated protocol. Acetabular contact stress and area were determined for seven activities. Peak stress ranged from 7.52 ± 2.11 MPa for heel‐strike during walking (233% BW) to 8.66 ± 3.01 MPa for heel‐strike during descending stairs (261% BW). Average contact area across all activities was 34% of the surface area of the acetabular cartilage. The distribution of contact stress was highly non‐uniform, and more variability occurred among subjects for a given activity than among activities for a single subject. The magnitude and area of contact stress were consistent between activities, although inter‐activity shifts in contact pattern were found as the direction of loading changed. Relatively small incongruencies between the femoral and acetabular cartilage had a large effect on the contact stresses. These effects tended to persist across all simulated activities. These results demonstrate the diversity and trends in cartilage contact stress in healthy hips during activities of daily living and provide a basis for future comparisons between normal and pathologic hips. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:1133–1139, 2012
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Etiology of Osteoarthritis of the Hip: An Integrated Mechanical Concept
Ganz, R., Leunig, M., Leunig-Ganz, K., & Harris, W. H. (2008) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-007-0060-z · Cited by 1,620
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623
Contact pressures in the human hip joint
Afoke, N., Byers, P., & Hutton, W. (1987) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.69b4.3611154 · Cited by 268
Cited by
Patient-specific analysis of cartilage and labrum mechanics in human hips with acetabular dysplasia
Henak, C. R., Abraham, C. L., Anderson, A. E., Maas, S. A., Ellis, B. J., Peters, C. L., & Weiss, J. A. (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.11.003 · Cited by 172
Self-citationFerraz, M. V. S., Bastos, F. S., Souza, B. G. S., & Vecchio, S. D. (2022) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-022-03566-z · Cited by 2
“[17] reported that the hip joint has low friction coefficient (0.”
Background
Metadata
- Authors
- Harris, M. D., Anderson, A. E., Henak, C. R., Ellis, B. J., Peters, C. L., & Weiss, J. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2011-12-30
- Volume
- 30
- Issue
- 7
- Pages
- 1133-1139
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2090717848
- Cited by
- 212
- References
- 3
- FWCI
- 14.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Finite element prediction of cartilage contact stresses in normal human hips. https://app.cochat.ai/papers/10.1002/jor.22040
- The paper
- Harris, M. D., Anderson, A. E., Henak, C. R., Ellis, B. J., Peters, C. L., & Weiss, J. A. (2012). Finite element prediction of cartilage contact stresses in normal human hips. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.22040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.