The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurements
Open accessAbstract
The accuracy of the nonlinear one-dimensional (1-D) equations of pressure and flow wave propagation in Voigt-type visco-elastic arteries was tested against measurements in a well-defined experimental 1:1 replica of the 37 largest conduit arteries in the human systemic circulation. The parameters required by the numerical algorithm were directly measured in the in vitro setup and no data fitting was involved. The inclusion of wall visco-elasticity in the numerical model reduced the underdamped high-frequency oscillations obtained using a purely elastic tube law, especially in peripheral vessels, which was previously reported in this paper [Matthys et al., 2007. Pulse wave propagation in a model human arterial network: Assessment of 1-D numerical simulations against in vitro measurements. J. Biomech. 40, 3476-3486]. In comparison to the purely elastic model, visco-elasticity significantly reduced the average relative root-mean-square errors between numerical and experimental waveforms over the 70 locations measured in the in vitro model: from 3.0% to 2.5% (p<0.012) for pressure and from 15.7% to 10.8% (p<0.002) for the flow rate. In the frequency domain, average relative errors between numerical and experimental amplitudes from the 5th to the 20th harmonic decreased from 0.7% to 0.5% (p<0.107) for pressure and from 7.0% to 3.3% (p<10(-6)) for the flow rate. These results provide additional support for the use of 1-D reduced modelling to accurately simulate clinically relevant problems at a reasonable computational cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Cruickshank, K., Riste, L., Anderson, S. G., Wright, J. S., Dunn, G., & Gosling, R. G. (2002) · Circulation · doi:10.1161/01.cir.0000033824.02722.f7 · Cited by 1,531
Spectral/hp Element Methods for Computational Fluid Dynamics
Karniadakis, G., & Sherwin, S. (2005) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780198528692.001.0001 · Cited by 1,473
Self-citationThe Mechanics of the Circulation
Caro, C. G., Pedley, T. J., Schroter, R. C., Seed, W. A., & Parker, K. H. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9781139013406 · Cited by 912
Self-citationOlufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862
Validation of a one-dimensional model of the systemic arterial tree
Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00037.2009 · Cited by 638
Computer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511
One-dimensional models for blood flow in arteries
Formaggia, L., Lamponi, D., & Quarteroni, A. M. (2003) · Journal of Engineering Mathematics · doi:10.1023/b:engi.0000007980.01347.29 · Cited by 500
Computational vascular fluid dynamics: problems, models and methods
Quarteroni, A., Tuveri, M., & Veneziani, A. (2000) · Computing and Visualization in Science · doi:10.1007/s007910050039 · Cited by 480
One-dimensional modelling of a vascular network in space-time variables
Sherwin, S. J., Franke, V., Peiró, J., & Parker, K. (2003) · Journal of Engineering Mathematics · doi:10.1023/b:engi.0000007979.32871.e2 · Cited by 464
Self-citationAlastruey, J., Parker, K. H., Peiró, J., Byrd, S. M., & Sherwin, S. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.07.008 · Cited by 436
Self-citationAn Anatomically Based Model of Transient Coronary Blood Flow in the Heart
Smith, N. P., Pullan, A. J., & Hunter, P. J. (2002) · SIAM Journal on Applied Mathematics · doi:10.1137/s0036139999355199 · Cited by 339
Sherwin, S. J., Formaggia, L., Peiró, J., & Franke, V. (2003) · International Journal for Numerical Methods in Fluids · doi:10.1002/fld.543 · Cited by 324
Self-citationArmentano, R. L., Barra, J. G., Levenson, J., Simon, A., & Pichel, R. H. (1995) · Circulation Research · doi:10.1161/01.res.76.3.468 · Cited by 297
E XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
Wave propagation in a model of the arterial circulation
Wang, J. J., & Parker, K. H. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.007 · Cited by 270
Self-citationMatthys, K. S., Alastruey, J., Peiró, J., Khir, A. W., Segers, P., Verdonck, P. R., Parker, K. H., & Sherwin, S. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.027 · Cited by 255
Self-citationDetermination of wave speed and wave separation in the arteries
Khir, A. W., O'Brien, A., Gibbs, J. S. R., & Parker, K. H. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00076-8 · Cited by 242
Self-citationMynard, J. P., & Nithiarasu, P. (2008) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1117 · Cited by 230
Numerical modeling of 1D arterial networks coupled with a lumped parameters description of the heart
Formaggia, L., Lamponi, D., Tuveri, M., & Veneziani, A. (2006) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840600857767 · Cited by 205
Mattfeld, D. C. (1996) · Evolutionary Search and the Job Shop · doi:10.1007/978-3-662-11712-5_8 · Cited by 177
Gariepy, J., Massonneau, M., Levenson, J., Heudes, D., & Simon, A. (1993) · Hypertension · doi:10.1161/01.hyp.22.1.111 · Cited by 167
Liang, F., Takagi, S., Himeno, R., & Liu, H. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.01.010 · Cited by 154
Large-artery stiffness, hypertension and cardiovascular risk in older patients
Blacher, J., & Safar, M. E. (2005) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio0307 · Cited by 141
Wan, J., Steele, B. N., Spicer, S. A., Strohband, S., Feijóo, G. R., Hughes, T. J. R., & Taylor, C. A. (2002) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840290010670 · Cited by 130
Steele, B. N., Wan, J., Ku, J. P., Hughes, T. J. R., & Taylor, C. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812201 · Cited by 127
Alastruey, J., Moore, S., Parker, K. H., David, T., Peiró, J., & Sherwin, S. J. (2007) · International Journal for Numerical Methods in Fluids · doi:10.1002/fld.1606 · Cited by 121
Self-citationBessems, D. D., Giannopapa, C. G., Rutten, M. C. M., & van de Vosse, F. N. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.014 · Cited by 120
Blood Flow in the Circle of Willis: Modeling and Calibration
DeVault, K. J., Gremaud, P. A., Novak, V., Olufsen, M. S., Vernières, G., & Zhao, P. (2008) · Multiscale Modeling and Simulation · doi:10.1137/07070231x · Cited by 120
On discontinuous Galerkin methods
Zienkiewicz, O. C., Taylor, R. L., Sherwin, S. J., & Peiró, J. (2003) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.884 · Cited by 114
Self-citationValdez‐Jasso, D., Bia, D., Zócalo, Y., Armentano, R. L., Haider, M. A., & Olufsen, M. S. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0236-7 · Cited by 108
Trachet, B., Reymond, P., Kips, J. G., Swillens, A., Buyzere, M. D., Suys, B. E., Stergiopulos, N., & Segers, P. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9945-1 · Cited by 101
Self-citationSteele, B. N., Olufsen, M. S., & Taylor, C. A. (2007) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840601068638 · Cited by 93
Analysis of Viscoelastic Wall Properties in Ovine Arteries
Valdez‐Jasso, D., Haider, M. A., Banks, H. T., Santana, D. B., Zócalo, Y., Armentano, R. L., & Olufsen, M. S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003093 · Cited by 77
Numerical assessment of time-domain methods for the estimation of local arterial pulse wave speed
Alastruey, J. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.12.002 · Cited by 67
Self-citationFunctional origin of reflected pressure waves in a multibranched model of the human arterial system
Karamanoglu, M., Gallagher, D., Avolio, A. P., & O’Rourke, M. F. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.267.5.h1681 · Cited by 63
Clinical application of wave intensity for the treatment of essential hypertension
Fujimoto, S., Mizuno, R., Saito, Y., & Nakamura, S. (2004) · Heart and Vessels · doi:10.1007/s00380-003-0725-9 · Cited by 58
Time domain computational modelling of 1D arterial networks in monochorionic placentas
Franke, V., Parker, K. H., Wee, L., et al. (2003) · ESAIM Mathematical Modelling and Numerical Analysis · doi:10.1051/m2an:2003047 · Cited by 29
Self-citationBank, A. J., & Kaiser, D. R. (2002) · Springer eBooks · doi:10.1007/978-3-642-56225-9_8 · Cited by 4
Cited by
Kissas, G., Yang, Y., Hwuang, E., Witschey, W. R., Detre, J. A., & Perdikaris, P. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.112623 · Cited by 647
Validation of a one-dimensional model of the systemic arterial tree
Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00037.2009 · Cited by 638
Pulse Wave Propagation in the Arterial Tree
van de Vosse, F. N., & Stergiopulos, N. (2011) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122109-160730 · Cited by 387
An introduction to wave intensity analysis
Parker, K. H. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0439-y · Cited by 309
Self-citationAssessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131
Self-citation
Metadata
- Authors
- Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2011-08
- Volume
- 44
- Issue
- 12
- Pages
- 2250-2258
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2111599533
- Cited by
- 441
- References
- 40
- FWCI
- 16.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.