The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
CEINMS: A toolbox to investigate the influence of different neural control solutions on the prediction of muscle excitation and joint moments during dynamic motor tasks
Open accessAbstract
Personalized neuromusculoskeletal (NMS) models can represent the neurological, physiological, and anatomical characteristics of an individual and can be used to estimate the forces generated inside the human body. Currently, publicly available software to calculate muscle forces are restricted to static and dynamic optimisation methods, or limited to isometric tasks only. We have created and made freely available for the research community the Calibrated EMG-Informed NMS Modelling Toolbox (CEINMS), an OpenSim plug-in that enables investigators to predict different neural control solutions for the same musculoskeletal geometry and measured movements. CEINMS comprises EMG-driven and EMG-informed algorithms that have been previously published and tested. It operates on dynamic skeletal models possessing any number of degrees of freedom and musculotendon units and can be calibrated to the individual to predict measured joint moments and EMG patterns. In this paper we describe the components of CEINMS and its integration with OpenSim. We then analyse how EMG-driven, EMG-assisted, and static optimisation neural control solutions affect the estimated joint moments, muscle forces, and muscle excitations, including muscle co-contraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
Corana, A., Marchesi, M., Martini, C., & Ridella, S. (1987) · ACM Transactions on Mathematical Software · doi:10.1145/29380.29864 · Cited by 1,531
An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo
Lloyd, D. G., & Besier, T. F. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00010-1 · Cited by 1,199
Self-citationDynamic Optimization of Human Walking
Anderson, F. C., & Pandy, M. G. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1392310 · Cited by 1,107
Buchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941
Self-citationModel-based estimation of muscle forces exerted during movements
Erdemir, A., McLean, S., Herzog, W., & van den Bogert, A. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.005 · Cited by 872
Tresch, M. C., Cheung, V. C. K., & d'Avella, A. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00222.2005 · Cited by 838
Flexing Computational Muscle: Modeling and Simulation of Musculotendon Dynamics
Millard, M., Uchida, T., Seth, A., & Delp, S. L. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023390 · Cited by 651
Grand challenge competition to predict in vivo knee loads
Fregly, B. J., Besier, T. F., Lloyd, D. G., Delp, S. L., Banks, S. A., Pandy, M. G., & D'Lima, D. D. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.22023 · Cited by 596
Self-citationChanges in firing rate of human motor units during linearly changing voluntary contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010193 · Cited by 553
Knee joint kinematics, kinetics and muscle co-contraction in knee osteoarthritis patient gait
Heiden, T. L., Lloyd, D. G., & Ackland, T. R. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.08.005 · Cited by 485
Self-citationA biomechanical investigation of the human hip
Crowninshield, R. D., Johnston, R. C., Andrews, J. G., & Brand, R. A. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90045-3 · Cited by 448
Modular control of human walking: A simulation study
Neptune, R. R., Clark, D. J., & Kautz, S. A. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.03.009 · Cited by 415
Muscle and external load contribution to knee joint contact loads during normal gait
Winby, C. R., Lloyd, D. G., Besier, T. F., & Kirk, T. B. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.019 · Cited by 374
Self-citationHarrington, M. E., Zavatsky, A. B., Lawson, S. E. M., Yuan, Z., & Theologis, T. N. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.003 · Cited by 365
Strategies of muscular support of varus and valgus isometric loads at the human knee
Lloyd, D. G., & Buchanan, T. S. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00095-1 · Cited by 363
Self-citationSartori, M., Reggiani, M., Farina, D., & Lloyd, D. G. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052618 · Cited by 330
Self-citationColby, S., Francisco, A., Bing, Y., Kirkendall, D., Finch, M., & Garrett, W. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280021501 · Cited by 233
Sartori, M., Farina, D., & Lloyd, D. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.10.009 · Cited by 229
Self-citationMuscle coordination and function during cutting movements
NEPTUNE, R. R., WRIGHT, I. C., & VAN DEN BOGERT, A. J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199902000-00014 · Cited by 183
A Model of Load Sharing Between Muscles and Soft Tissues at the Human Knee During Static Tasks
Lloyd, D. G., & Buchanan, T. S. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796019 · Cited by 181
Self-citationInfluences on knee movement strategies during walking in persons with medial knee osteoarthritis
SchmitT, L. C., & Rudolph, K. S. (2007) · Arthritis Care & Research · doi:10.1002/art.22889 · Cited by 166
MANAL, K. T., & Buchanan, T. S. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00152-0 · Cited by 159
MANAL, K. T., & Buchanan, T. S. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023457 · Cited by 146
Routledge Handbook of Biomechanics and Human Movement Science
Hong, Y. (2008) · Routledge eBooks · doi:10.4324/9780203889688 · Cited by 141
Sartori, M., Gizzi, L., Lloyd, D. G., & Farina, D. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00079 · Cited by 139
Self-citationDifferences in central control of m. biceps brachii in movement tasks and force tasks
Tax, A. A. M., van der Gon, J. J. D., Gielen, C. C. A. M., & Kleyne, M. (1990) · Experimental Brain Research · doi:10.1007/bf00228882 · Cited by 131
Shao, Q., MacLeod, T. D., MANAL, K. T., & Buchanan, T. S. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0131-2 · Cited by 110
Buchanan, T. S., & Shreeve, D. A. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796044 · Cited by 108
Amarantini, D., & Martin, L. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.020 · Cited by 98
Modeling the Human Knee for Assistive Technologies
Sartori, M., Reggiani, M., Pagello, E., & Lloyd, D. G. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208746 · Cited by 65
Self-citationWinby, C. R., Gerus, P., Kirk, T. B., & Lloyd, D. G. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.09.006 · Cited by 64
Self-citationBarrett, R., Besier, T. F., & Lloyd, D. G. (2007) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2007.07.005 · Cited by 53
Self-citationState of the art and current limits of musculo-skeletal models for clinical applications
Chèze, L. L., Moissenet, F., & Dumas, R. (2012) · Movement & Sport Sciences - Science & Motricité · doi:10.1051/sm/2012026 · Cited by 29
Cited by
OpenCap: Human movement dynamics from smartphone videos
Uhlrich, S. D., Falisse, A., Kidziński, Ł., Muccini, J., Ko, M., Chaudhari, A. S., Hicks, J. L., & Delp, S. L. (2023) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1011462 · Cited by 449
Techniques to determine knee joint contact forces during squatting: A systematic review
Kothurkar, R., & Lekurwale, R. (2022) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/09544119221091609 · Cited by 9
Metadata
- Authors
- Pizzolato, C., Lloyd, D. G., Sartori, M., Ceseracciu, E., Besier, T. F., Fregly, B. J., & Reggiani, M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 48
- Issue
- 14
- Pages
- 3929-3936
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1755608697
- Cited by
- 349
- References
- 36
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.