Inter-session repeatability of markerless motion capture gait kinematics
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The clinical uptake and influence of gait analysis has been hindered by inherent limitations of marker-based motion capture systems, which have long been the standard method for the collection of gait data including kinematics. Markerless motion capture offers an alternative method for the collection of gait kinematics that presents several practical benefits over marker-based systems. This work aimed to determine the reliability of lower limb gait kinematics from video based markerless motion capture using an established experimental protocol for testing reliability. Eight healthy adult participants performed three sessions of five over-ground walking trials in their own self-selected clothing, separated by an average of 8.5 days, while eight synchronized and calibrated cameras recorded video. Three-dimensional pose estimates from the video data were used to compute lower limb joint angles. Inter-session variability, inter-trial variability, and the variability ratio were used to assess the reliability of the gait kinematics. Compared to repeatability studies based on marker-based motion capture, inter-trial variability was slightly greater than previously reported for some angles, with an average across all joint angles of 2.5°. Inter-session variability was smaller on average than all previously reported values, with an average across all joint angles of 2.8°. Variability ratios were all smaller than those previously reported with an average of 1.1, indicating that the multi-session protocol increased the total variability of joint angles by 10% of the inter-trial variability. These results indicate that gait kinematics can be reliably measured using markerless motion capture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microsoft COCO: Common Objects in Context
Lin, T.-Y., Maire, M., Belongie, S., Hays, J., Perona, P., Ramanan, D., Dollár, P., & Zitnick, C. L. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10602-1_48 · Cited by 45,460
DeepLabCut: markerless pose estimation of user-defined body parts with deep learning
Mathis, A., Mamidanna, P., Cury, K. M., Abe, T., Murthy, V. N., Mathis, M. W., & Bethge, M. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0209-y · Cited by 5,187 · cited 1×
“These systems often use arrays of two-dimensional (2D) video cameras or depth sensors in combination with machine learning algorithms to estimate human pose during physical tasks and have been implemented to varying levels of success (Mathis et al., 2018; Mathis et al., 2020).”
BackgroundGrood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805 · cited 1×
“Lower limb joint angles were calculated using the standard Cardan rotation sequence (X-Y-Z), equivalent to the joint coordinate system (Grood and Suntay, 1983), and timenormalized to the gait cycle using the heel-strike events.”
MethodMicrosoft COCO: Common Objects in Context
Lin, T.-Y., Maire, M., Belongie, S., Bourdev, L., Girshick, R., Hays, J., Perona, P., Ramanan, D., Zitnick, C. L., & Dollár, P. (2014) · arXiv · doi:10.48550/arxiv.1405.0312 · Cited by 2,579
Zeni, J. A., Richards, J. G., & Higginson, J. S. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.07.007 · Cited by 1,261 · cited 1×
“(Zeni et al., 2008) to determine heel-strike and toe-off gait events throughout each trial.”
BackgroundHuman movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
The reliability of three-dimensional kinematic gait measurements: A systematic review
McGinley, J. L., Baker, R., Wolfe, R., & Morris, M. E. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.09.003 · Cited by 1,144 · cited 1×
“The changing collection conditions can lead to inconsistent findings or conclusions across gait studies, demonstrating that clinically acceptable errors are possible but not always achieved in gait analysis (McGinley et al., 2009).”
BackgroundAstephen, J. L., Deluzio, K. J., Caldwell, G. E., & Dunbar, M. J. (2008) · Journal of Orthopaedic Research · doi:10.1002/jor.20496 · Cited by 561 · cited 1×
“This data has the potential to help monitor disease progression, improve physical therapy, and aid in surgical decision-making (Astephen et al., 2008; Crowell and Davis, 2011; Haim et al., 2012; Smania et al., 2011; Wren et al., 2011).”
BackgroundSelf-citationHuman movement analysis using stereophotogrammetry
Della Croce, U., Leardini, A., Chiari, L., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.003 · Cited by 544
Gait retraining to reduce lower extremity loading in runners
Crowell, H. P., & Davis, I. S. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.09.003 · Cited by 403 · cited 1×
“This data has the potential to help monitor disease progression, improve physical therapy, and aid in surgical decision-making (Astephen et al., 2008; Crowell and Davis, 2011; Haim et al., 2012; Smania et al., 2011; Wren et al., 2011).”
Background
Cited by
OpenCap: Human movement dynamics from smartphone videos
Uhlrich, S. D., Falisse, A., Kidziński, Ł., Muccini, J., Ko, M., Chaudhari, A. S., Hicks, J. L., & Delp, S. L. (2023) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1011462 · Cited by 449
Concurrent assessment of gait kinematics using marker-based and markerless motion capture
Kanko, R. M., Laende, E. K., Davis, E. M., Selbie, W. S., & Deluzio, K. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110665 · Cited by 403
Self-citationWade, L., Needham, L., McGuigan, P., & Bilzon, J. (2022) · PeerJ · doi:10.7717/peerj.12995 · Cited by 384
The accuracy of several pose estimation methods for 3D joint centre localisation
Needham, L., Evans, M., Cosker, D. P., Wade, L., McGuigan, P. M., Bilzon, J. L., & Colyer, S. L. (2021) · Scientific Reports · doi:10.1038/s41598-021-00212-x · Cited by 190
“Once all joints can be estimated to this level of accuracy the focus of attention instead turns to between session repeatability 46 , which can be problematic for marker-based systems when markers are not placed in identical locations between sessions 47 .”
BackgroundKanko, R. M., Laende, E. K., Strutzenberger, G., Brown, M., Selbie, W. S., DePaul, V., Scott, S. H., & Deluzio, K. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110414 · Cited by 178
Self-citationGait analysis to monitor fracture healing of the lower leg
Warmerdam, E., Orth, M., Pohlemann, T., & Ganse, B. (2023) · Bioengineering · doi:10.3390/bioengineering10020255 · Cited by 47
“Markerless motion capture systems often use multiple synchronized cameras to detect the pose of one or multiple individuals based on machine learning models [59].”
Background
Metadata
- Authors
- Kanko, R. M., Laende, E., Selbie, W. S., & Deluzio, K. J.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 121
- Pages
- 110422
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W3142144251
- Cited by
- 179
- References
- 28
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.