Inter-session repeatability of markerless motion capture gait kinematics
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The clinical uptake and influence of gait analysis has been hindered by inherent limitations of marker-based motion capture systems, which have long been the standard method for the collection of gait data including kinematics. Markerless motion capture offers an alternative method for the collection of gait kinematics that presents several practical benefits over marker-based systems. This work aimed to determine the reliability of lower limb gait kinematics from video based markerless motion capture using an established experimental protocol for testing reliability. Eight healthy adult participants performed three sessions of five over-ground walking trials in their own self-selected clothing, separated by an average of 8.5 days, while eight synchronized and calibrated cameras recorded video. Three-dimensional pose estimates from the video data were used to compute lower limb joint angles. Inter-session variability, inter-trial variability, and the variability ratio were used to assess the reliability of the gait kinematics. Compared to repeatability studies based on marker-based motion capture, inter-trial variability was slightly greater than previously reported for some angles, with an average across all joint angles of 2.5°. Inter-session variability was smaller on average than all previously reported values, with an average across all joint angles of 2.8°. Variability ratios were all smaller than those previously reported with an average of 1.1, indicating that the multi-session protocol increased the total variability of joint angles by 10% of the inter-trial variability. These results indicate that gait kinematics can be reliably measured using markerless motion capture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microsoft COCO: Common Objects in Context
Lin, T.-Y., Maire, M., Belongie, S., Hays, J., Perona, P., Ramanan, D., Dollár, P., & Zitnick, C. L. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10602-1_48 · Cited by 45,460
DeepLabCut: markerless pose estimation of user-defined body parts with deep learning
Mathis, A., Mamidanna, P., Cury, K. M., Abe, T., Murthy, V. N., Mathis, M. W., & Bethge, M. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0209-y · Cited by 5,187 · cited 1×
“These systems often use arrays of two-dimensional (2D) video cameras or depth sensors in combination with machine learning algorithms to estimate human pose during physical tasks and have been implemented to varying levels of success (Mathis et al., 2018; Mathis et al., 2020).”
BackgroundGrood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805 · cited 1×
“Lower limb joint angles were calculated using the standard Cardan rotation sequence (X-Y-Z), equivalent to the joint coordinate system (Grood and Suntay, 1983), and timenormalized to the gait cycle using the heel-strike events.”
MethodMicrosoft COCO: Common Objects in Context
Lin, T.-Y., Maire, M., Belongie, S., Bourdev, L., Girshick, R., Hays, J., Perona, P., Ramanan, D., Zitnick, C. L., & Dollár, P. (2014) · arXiv · doi:10.48550/arxiv.1405.0312 · Cited by 2,579
Zeni, J. A., Richards, J. G., & Higginson, J. S. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.07.007 · Cited by 1,261 · cited 1×
“(Zeni et al., 2008) to determine heel-strike and toe-off gait events throughout each trial.”
BackgroundHuman movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
The reliability of three-dimensional kinematic gait measurements: A systematic review
McGinley, J. L., Baker, R., Wolfe, R., & Morris, M. E. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.09.003 · Cited by 1,144 · cited 1×
“The changing collection conditions can lead to inconsistent findings or conclusions across gait studies, demonstrating that clinically acceptable errors are possible but not always achieved in gait analysis (McGinley et al., 2009).”
BackgroundAstephen, J. L., Deluzio, K. J., Caldwell, G. E., & Dunbar, M. J. (2008) · Journal of Orthopaedic Research · doi:10.1002/jor.20496 · Cited by 561 · cited 1×
“This data has the potential to help monitor disease progression, improve physical therapy, and aid in surgical decision-making (Astephen et al., 2008; Crowell and Davis, 2011; Haim et al., 2012; Smania et al., 2011; Wren et al., 2011).”
BackgroundSelf-citationHuman movement analysis using stereophotogrammetry
Della Croce, U., Leardini, A., Chiari, L., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.003 · Cited by 544
Gait retraining to reduce lower extremity loading in runners
Crowell, H. P., & Davis, I. S. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.09.003 · Cited by 403 · cited 1×
“This data has the potential to help monitor disease progression, improve physical therapy, and aid in surgical decision-making (Astephen et al., 2008; Crowell and Davis, 2011; Haim et al., 2012; Smania et al., 2011; Wren et al., 2011).”
BackgroundConcurrent assessment of gait kinematics using marker-based and markerless motion capture
Kanko, R. M., Laende, E. K., Davis, E. M., Selbie, W. S., & Deluzio, K. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110665 · Cited by 403
Self-citationMeasurement and management of errors in quantitative gait data
Schwartz, M. H., Trost, J. P., & Wervey, R. A. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2003.09.011 · Cited by 395 · cited 1×
“which measures subjects’ inter-session variability, inter-trial variability, and the ratio between them (Schwartz et al., 2004).”
BackgroundEfficacy of Clinical Gait Analysis: A Systematic Review
Wren, T. A. L., Gorton, G. E., Õunpuu, S., & Tucker, C. A. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.03.027 · Cited by 312
Assessment of the kinematic variability among 12 motion analysis laboratories
Gorton, G. E., Hebert, D. A., & Gannotti, M. E. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.10.060 · Cited by 283 · cited 2×
“Standardized protocols have been shown to reduce undue variability in data collected on the same subject at different laboratories by different operators (Gorton et al., 2009); however, some inter-operator variability persists even when an identical collection protocol and the same laboratory are used (Maynard et al.”
BackgroundMethodA Primer on Motion Capture with Deep Learning: Principles, Pitfalls, and Perspectives
Mathis, A., Schneider, S., Lauer, J., & Mathis, M. W. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.017 · Cited by 231
Improved Gait After Repetitive Locomotor Training in Children with Cerebral Palsy
Smania, N., Bonetti, P., Gandolfi, M., Cosentino, A., Waldner, A., Hesse, S., Werner, C., Bisoffi, G., Geroin, C., & Munari, D. (2011) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318201741e · Cited by 198 · cited 1×
“This data has the potential to help monitor disease progression, improve physical therapy, and aid in surgical decision-making (Astephen et al., 2008; Crowell and Davis, 2011; Haim et al., 2012; Smania et al., 2011; Wren et al., 2011).”
BackgroundRepeatability of an optimised lower body model
Charlton, I., Tate, P., Smyth, P., & Roren, L. (2003) · Gait & Posture · doi:10.1016/j.gaitpost.2003.09.004 · Cited by 182 · cited 2×
“Since IK techniques have been shown to reduce measurement variability (Charlton et al., 2004; Kainz et al., 2017), we performed our analyses using both the default IK model and the optional 6DOF ankle model implemented in Theia3D.”
BackgroundMethodKanko, R. M., Laende, E. K., Strutzenberger, G., Brown, M., Selbie, W. S., DePaul, V., Scott, S. H., & Deluzio, K. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110414 · Cited by 178
Self-citationReliability of four models for clinical gait analysis
Kainz, H., Graham, D., Edwards, J., Walsh, H. P. J., Maine, S., Boyd, R. N., Lloyd, D. G., Modenese, L., & Carty, C. P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.04.001 · Cited by 173 · cited 2×
“Since IK techniques have been shown to reduce measurement variability (Charlton et al., 2004; Kainz et al., 2017), we performed our analyses using both the default IK model and the optional 6DOF ankle model implemented in Theia3D.”
BackgroundMethodThe role of gait analysis in the orthopaedic management of ambulatory cerebral palsy
Narayanan, U. G. (2007) · Current Opinion in Pediatrics · doi:10.1097/mop.0b013e3280118a6d · Cited by 103 · cited 1×
“These limitations include lengthy data collection times, the requirement of highly skilled experimenter capable of accurate marker placement, dedicated laboratory space, and the intrusive nature of the technology and experimental protocols on the subject or patient, which in turn limit the use of this data in clinical…”
MethodHow Different Marker Sets Affect Joint Angles in Inverse Kinematics Framework
Mantovani, G., & Lamontagne, M. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4034708 · Cited by 99 · cited 1×
“These findings indicate that the implementation of an IK approach to determine subject pose had little effect on the repeatability of the markerless kinematics, despite IK techniques having been shown in some studies to reduce the variability of kinematic measurements compared to direct kinematic (DK) approaches (Char…”
BackgroundWren, T. A. L., Otsuka, N. Y., Bowen, R. E., et al. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.06.002 · Cited by 96 · cited 1×
“This data has the potential to help monitor disease progression, improve physical therapy, and aid in surgical decision-making (Astephen et al., 2008; Crowell and Davis, 2011; Haim et al., 2012; Smania et al., 2011; Wren et al., 2011).”
BackgroundIntra-rater and inter-rater reliability of gait measurements with CODA mpx30 motion analysis system
Maynard, V., Bakheit, A. M. O., Oldham, J. A., & Freeman, J. A. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00051-6 · Cited by 92 · cited 1×
“, 2009); however, some inter-operator variability persists even when an identical collection protocol and the same laboratory are used (Maynard et al., 2003).”
BackgroundReliability of 3D gait data across multiple laboratories
Kaufman, K. R., Miller, E. J., Kingsbury, T. D., Esposito, E. R., Wolf, E. J., Wilken, J. M., & Wyatt, M. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.07.075 · Cited by 85 · cited 1×
“, 2004) and three used 6DOF biomechanical models (Manca et al., 2010; Caravaggi et al., 2011; Kaufman et al., 2016).”
MethodHaim, A., Rubin, G., Rozen, N., Goryachev, Y., & Alon Wolf, A. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.10.017 · Cited by 67 · cited 1×
“This data has the potential to help monitor disease progression, improve physical therapy, and aid in surgical decision-making (Astephen et al., 2008; Crowell and Davis, 2011; Haim et al., 2012; Smania et al., 2011; Wren et al., 2011).”
BackgroundRepeatability of a new protocol for gait analysis in adult subjects
Manca, M., Leardini, A., Cavazza, S., Ferraresi, G., Marchi, P., Zanaga, E., & Benedetti, M. G. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.05.011 · Cited by 59 · cited 2×
“, 2004) and three used 6DOF biomechanical models (Manca et al., 2010; Caravaggi et al., 2011; Kaufman et al., 2016).”
MethodResultMentiplay, B. F., & Clark, R. A. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.05.033 · Cited by 49 · cited 1×
“We acknowledge that greater differences may be seen if the knee and hip joints were additionally allowed 6DOF; however, other studies have shown similar reliability between IK and DK techniques and there is currently no implemented option for 6DOF knee and hip joints in Theia3D (Mentiplay and Clark, 2018; Horsak et al…”
ResultDonati, M., Camomilla, V., Vannozzi, G., & Cappozzo, A. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.04.018 · Cited by 40 · cited 1×
“While effective alternative anatomical calibration techniques have been demonstrated that do not require highly trained operators, they are still time intensive and somewhat intrusive (Donati et al., 2008).”
Background
Cited by
OpenCap: Human movement dynamics from smartphone videos
Uhlrich, S. D., Falisse, A., Kidziński, Ł., Muccini, J., Ko, M., Chaudhari, A. S., Hicks, J. L., & Delp, S. L. (2023) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1011462 · Cited by 449
Concurrent assessment of gait kinematics using marker-based and markerless motion capture
Kanko, R. M., Laende, E. K., Davis, E. M., Selbie, W. S., & Deluzio, K. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110665 · Cited by 403
Self-citationWade, L., Needham, L., McGuigan, P., & Bilzon, J. (2022) · PeerJ · doi:10.7717/peerj.12995 · Cited by 384
The accuracy of several pose estimation methods for 3D joint centre localisation
Needham, L., Evans, M., Cosker, D. P., Wade, L., McGuigan, P. M., Bilzon, J. L., & Colyer, S. L. (2021) · Scientific Reports · doi:10.1038/s41598-021-00212-x · Cited by 190
“Once all joints can be estimated to this level of accuracy the focus of attention instead turns to between session repeatability 46 , which can be problematic for marker-based systems when markers are not placed in identical locations between sessions 47 .”
BackgroundKanko, R. M., Laende, E. K., Strutzenberger, G., Brown, M., Selbie, W. S., DePaul, V., Scott, S. H., & Deluzio, K. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110414 · Cited by 178
Self-citation
Metadata
- Authors
- Kanko, R. M., Laende, E., Selbie, W. S., & Deluzio, K. J.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 121
- Pages
- 110422
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W3142144251
- Cited by
- 179
- References
- 28
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.