CoChat

Development and validation of an extraction method for the analysis of perfluoroalkyl substances (PFASs) in environmental and biotic matrices

Groffen, Thimo, Lasters, Robin, Lemière, Filip, Willems, Tim, Eens, Marcel, Bervoets, Lieven, Prinsen, Els · 2019 · Journal of Chromatography B
Cited by 52

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Although long chained PFASs have been phased-out in several countries, their persistence in the environment and bioaccumulative potential cause the environmental and biotic concentrations to remain high, highlighting the need to further monitor these pollutants. Currently several methods are used for the quantification of perfluoroalkyl substances (PFASs) in biological matrices including different ways to correct for recovery losses, each with its specific pros and contras. With this paper we aim to re-evaluate current methodologies and to create an updated new analytical guideline that is applicable for both abiotic and biotic matrices. The developed LC/MS/MS method was validated and shown to be specific, selective, linear, robust and sensitive. Reliable results could still be obtained 6 days after extraction. The recoveries varied, depending on the matrix, between 1% and 100%, but nevertheless, a high accuracy was obtained even at the lowest recoveries. A reduction of sample mass could significantly increase method recoveries and therefore it is highly recommended to take less matrix. We confirmed that using the ISTD closest in terms of functional group and carbon chain length is a suitable method for the quantification of PFASs that lack a corresponding ISTD. The newly described method was, depending on the matrix, similar in terms of sensitivity and reliability compared to a frequently used method and could be used simultaneously in future monitoring studies. Therefore, we recommend to select the purification method based on the target analytes as well as the sample matrix. CAPSULE: The newly described method was similar in terms of sensitivity and reliability compared to a frequently used method and a selection of purification methods should be based on the target analyte and sample matrix.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jchromb.2019.03.034

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 52

Metadata

Authors
Groffen, T., Lasters, R., Lemière, F., Willems, T., Eens, M., Bervoets, L., & Prinsen, E.
Venue
Journal of Chromatography B
Publisher
Elsevier BV
Published
2019-05
Volume
1116
Pages
30-37
ISSN
1570-0232 (ISSN-L)
OpenAlex
W2930143009
Cited by
52
References
6
FWCI
2.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.