The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Intravascular Ultrasound Guidance to Minimize the Use of Iodine Contrast in Percutaneous Coronary Intervention
Open accessAbstract
Objective To evaluate the impact of IVUS guidance on the final volume of contrast agent utilized in patients undergoing PCI. Background To date, few approaches have been described to reduce the final dose of contrast agent in percutaneous coronary interventions (PCI). We hypothesized that intravascular ultrasound (IVUS) might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast. Methods A total of 83 patients were randomized to I) angiography-guided PCI or II) IVUS-guided PCI, both groups treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months. Results The median total volume of contrast was 64.5 ml (interquartile range [IQR] 42.8 – 97.0 ml; minimum 19 ml; maximum 170 ml) in angiography-guided group vs. 20.0 ml (IQR 12.5 – 30.0 ml; minimum 3 ml; maximum 54 ml) in IVUS-guided group (p<0.001). Similarly, the median volume of contrast / creatinine clearance ratio was significantly lower among patients treated with IVUS-guided PCI (1.0 [IQR 0.6 – 1.9] vs. 0.4 [IQR 0.2 – 0.6] respectively; p<0.001). In-hospital and 4-month outcomes were not different between patients randomized to angiography-guided and IVUS-guided PCI. Conclusions Thoughtful and extensive utilization of IVUS as the primary imaging tool to guide PCI is safe, and markedly reduces the volume of iodine contrast, compared to angiography-alone guidance. The use of IVUS should be considered for patients at high risk for contrast-induced acute kidney injury or volume overload undergoing coronary angioplasty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Third Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., & White, H. D. (2012) · Circulation · doi:10.1161/cir.0b013e31826e1058 · Cited by 2,985
Cited by
Räber, L., Mintz, G. S., Koskinas, K. C., Johnson, T. W., Holm, N. R., Onuma, Y., Radu, M. D., Joner, M., Yu, B., Jia, H., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy285 · Cited by 770
Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation
Zhang, J., Gao, X., Kan, J., Ge, Z., Han, L., Lu, S., Tian, N., Lin, S., Lu, Q., Wu, X., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.013 · Cited by 665
Metadata
- Authors
- Mariani, J., Guedes, C., Soares, P., Zalc, S., Campos, C. M., Lopes, A. C., Spadaro, A. G., Perin, M. A., Filho, A. E., Takimura, C. K., Ribeiro, E., Kalil-Filho, R., Edelman, E. R., Serruys, P. W., & Lemos, P. A.
- Venue
- JACC: Cardiovascular Interventions
- Publisher
- Elsevier BV
- Published
- 2014-11
- Volume
- 7
- Issue
- 11
- Pages
- 1287-1293
- ISSN
- 1876-7605 (ISSN-L)
- 1936-8798
- OpenAlex
- W168347120
- Cited by
- 214
- References
- 1
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.