Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 171

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Identification of potential indoor air pollutants in schools

Becerra, Jose A., Lizana, Jesus, Gil, Maite, Barrios-Padura, Angela, Blondeau, Patrice, Chacartegui, Ricardo · 2020 · Journal of Cleaner Production

Abstract

Abstract Indoor air quality in school buildings plays an important role in students' wellbeing and performance. The presence and evolution of different compounds are directly affected by indoor activities, classroom materials and equipment, along with outside conditions derived from location and surrounding activities. Despite high CO2 concentration levels in classrooms being regulated in some regions, there is a wide range of pollutant substances that should be considered. This paper analyses a wide spectrum of air pollutants in school buildings to identify their relative impact and relevance. Measured values are compared to the recommended indoor air guideline values (IAGVs) reported in different national regulations and health organisations. This characterisation helps to evaluate the impact of potential indoor and outdoor air pollutant sources in schools; to define appropriate criteria to analyse the exposure to a wide range of air pollutants; and to develop appropriate strategies in order to reduce the exposure to air pollutants and minimise adverse health effects. A set of high priority pollutants, such as CO2, PM2.5, PM10, TVOC and a set of specific aldehydes and volatile organic compounds, were monitored through active and passive measurement in 18 classrooms of 9 Mediterranean schools. These schools were selected according to their construction period, design typology, and students’ ages. The measurements taken during teaching hours show mean CO2 concentration values of 1530 ppm, oscillating in a range from −24% to +31%. The analysis highlights that along with occupancy, the main indoor air pollutant sources in schools are related to settled dust that produces suspension particles during classroom activity, affecting the relative differences in the mean PM concentration value from +36% to +193%. Moreover, aldehydes show high concentration values in infant classrooms, showing relative differences in the mean value from +163% to +313%. Additionally, the study demonstrates that outdoor air pollutant sources in school surroundings, such as high-density traffic areas or industrial activities, play an important role in final indoor air quality performance, affecting PM10, PM2.5, TVOC, benzene and toluene levels. The measurements show good indoor air quality values, below the recommended indoor air quality guidelines, but they also highlight the monitoring interest of some specific compounds for future regulations, such as PM2.5, PM10, TVOC, benzene, toluene or formaldehyde.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jclepro.2019.118420

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Becerra, J. A., Lizana, J., Gil, M., Barrios-Padura, A., Blondeau, P., & Chacartegui, R.
Venue
Journal of Cleaner Production
Publisher
Elsevier BV
Published
2020-01
Volume
242
Pages
118420
ISSN
0959-6526 (ISSN-L)
OpenAlex
W2974594774
Cited by
171
References
1
FWCI
6.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.