CoChat

Noninvasive Evaluation of Cardiac Allograft Rejection by Cellular and Functional Cardiac Magnetic Resonance

Open access
Wu, Yijen L., Ye, Qing, Sato, Kazuya, Foley, Lesley M., Hitchens, T. Kevin, Ho, Chien · 2009 · JACC: Cardiovascular Imaging
Cited by 72

The DOI matches its Crossref record.

Abstract

OBJECTIVES The goal of this study is to use cardiac MRI to establish sensitive and reliable indexes for non-invasive detection of acute cardiac allograft rejection. BACKGROUND Appropriate surveillance for acute allograft rejection is vitally important for graft survival. The current gold standard for diagnosing and staging rejection after organ transplantation is endomyocardial biopsy, which is not only invasive but also prone to sampling errors. The motivation of this study is to establish MRI-based alternative that is non-invasive and sensitive for early detection of allograft rejection before reversible organ damage occurs. METHODS We have developed a non-invasive two-pronged approach to detect acute cardiac allograft rejection using a rodent working heart and lung transplantation model. We use MRI to detect immune-cell infiltration at sites of rejection by monitoring the accumulation of dextran-coated ultra-small superparamagnetic-iron-oxide (USPIO)-labeled immune cells (in particular macrophages) in-vivo. Simultaneously, we use MRI tagging and strain analysis to detect regional myocardial function loss resulting from acute rejection. RESULTS Immune cells, mainly macrophages and monocytes, are made visible with MRI by in-vivo labeling with USPIO. Our data show that immune-cell infiltration in cardiac allograft rejection is highly heterogeneous. Thus, it is not surprising to find inconsistencies between rejection and endomyocardial biopsy results because of the limited number and small samples available. This spatially heterogeneous pattern has not otherwise been observed. Tagged MRI and strain analysis show that, like immune-cell infiltration, ventricular functional loss is also highly heterogeneous. Although changes in global systolic function are generally not observed until the later stages of rejection, our data reveal that a functional index derived from local strain analysis correlates well with rejection grades, which may be a more sensitive parameter for detecting early rejection. CONCLUSIONS Cardiac MRI is non-invasive and provides a 3D, whole-heart perspective of the rejection status, potentially allowing more reliable detection of acute allograft rejection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcmg.2009.01.013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Authors
Wu, Y. L., Ye, Q., Sato, K., Foley, L. M., Hitchens, T. K., & Ho, C.
Venue
JACC: Cardiovascular Imaging
Publisher
Elsevier BV
Published
2009-06
Volume
2
Issue
6
Pages
731-741
ISSN
  • 1876-7591 (ISSN-L)
  • 1936-878X
OpenAlex
W1705921322
Cited by
72
References
0
FWCI
7.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Evaluation of Cardiac Allograft Rejection by Cellular and Functional Cardiac Magnetic Resonance. https://app.cochat.ai/papers/10.1016/j.jcmg.2009.01.013
The paper
Wu, Y. L., Ye, Q., Sato, K., Foley, L. M., Hitchens, T. K., & Ho, C. (2009). Noninvasive Evaluation of Cardiac Allograft Rejection by Cellular and Functional Cardiac Magnetic Resonance. JACC: Cardiovascular Imaging. https://doi.org/10.1016/j.jcmg.2009.01.013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.