The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Direct T2 Quantification of Myocardial Edema in Acute Ischemic Injury
Open accessAbstract
OBJECTIVES To evaluate the utility of rapid, quantitative T2 mapping compared with conventional T2-weighted imaging in patients presenting with various forms of acute myocardial infarction. BACKGROUND T2-weighted cardiac magnetic resonance (CMR) identifies myocardial edema before the onset of irreversible ischemic injury and has shown value in risk-stratifying patients with chest pain. Clinical acceptance of T2-weighted CMR has, however, been limited by well-known technical problems associated with existing techniques. T2 quantification has recently been shown to overcome these problems; we hypothesized that T2 measurement in infarcted myocardium versus remote regions versus zones of microvascular obstruction in acute myocardial infarction patients could help reduce uncertainty in interpretation of T2-weighted images. METHODS T2 values using a novel mapping technique were prospectively recorded in 16 myocardial segments in 27 patients admitted with acute myocardial infarction. Regional T2 values were averaged in the infarct zone and remote myocardium, both defined by a reviewer blinded to the results of T2 mapping. Myocardial T2 was also measured in a group of 21 healthy volunteers. RESULTS T2 of the infarct zone was 69 ± 6 ms compared with 56 ± 3.4 ms for remote myocardium (p < 0.0001). No difference in T2 was observed between remote myocardium and myocardium of healthy volunteers (56 ± 3.4 ms and 55.5 ± 2.3 ms, respectively, p = NS). T2 mapping allowed for the detection of edematous myocardium in 26 of 27 patients; by comparison, segmented breath-hold T2-weighted short tau inversion recovery images were negative in 7 and uninterpretable in another 2 due to breathing artifacts. Within the infarct zone, areas of microvascular obstruction were characterized by a lower T2 value (59 ± 6 ms) compared with areas with no microvascular obstruction (71.6 ± 10 ms, p < 0.0001). T2 mapping provided consistent high-quality results in patients unable to breath-hold and in those with irregular heart rhythms, in whom short tau inversion recovery often yielded inadequate imaging. CONCLUSIONS Quantitative T2 mapping reliably identifies myocardial edema without the limitations encountered by T2-weighted short tau inversion recovery imaging, and may therefore be clinically more robust in showing acute ischemic injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., White, H. D., TASK FORCE MEMBERS: Chairpersons: Kristian Thygesen (Denmark), J. S. A. (., Biomarker Group: Allan S. Jaffe, C. (., ECG Group: Bernard Chaitman, C.-O. (., Imaging Group: Richard Underwood, C. (., Intervention Group: Jean-Pierre Bassand, C.-O. (., Clinical Investigation Group: Paul W. Armstrong, C. (., Global Perspective Group: Philip A. Poole-Wilson, C. (., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187397 · Cited by 4,230
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Self-citationThygesen, K. A. (2007) · Circulation · Cited by 3,126
T2 quantification for improved detection of myocardial edema
Giri, S., Chung, Y.-C., Merchant, A., Mihai, G., Rajagopalan, S., Raman, S. V., & Simonetti, O. P. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-56 · Cited by 680
Self-citation"Black blood" T2-weighted inversion-recovery MR imaging of the heart.
Simonetti, O. P., Finn, J. P., White, R. D., Laub, G., & Henry, D. A. (1996) · Radiology · doi:10.1148/radiology.199.1.8633172 · Cited by 560
Self-citationAletras, A. H., Tilak, G. S., Natanzon, A., Hsu, L.-Y., Gonzalez, F. M., Hoyt, R. F., & Arai, A. E. (2006) · Circulation · doi:10.1161/circulationaha.105.576025 · Cited by 532
Friedrich, M. G., Abdel-Aty, H., Taylor, A., Schulz-Menger, J., Messroghli, D., & Dietz, R. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.01.019 · Cited by 514
Hor, K. N., Gottliebson, W. M., Carson, C., Wash, E., Cnota, J., Fleck, R., Wansapura, J., Klimeczek, P., Al-Khalidi, H. R., Chung, E. S., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.11.006 · Cited by 379
Cury, R. C., Shash, K., Nagurney, J. T., Rosito, G., Shapiro, M. D., Nomura, C. H., Abbara, S., Bamberg, F., Ferencik, M., Schmidt, E. J., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.740597 · Cited by 259
Cited by
Puntmann, V. O., Carerj, M. L., Wieters, I., Fahim, M., Arendt, C., Hoffmann, J., Shchendrygina, A., Escher, F., Vasa-Nicotera, M., Zeiher, A. M., et al. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2020.3557 · Cited by 2,208
Cardiovascular Magnetic Resonance in Nonischemic Myocardial Inflammation
Ferreira, V. M., Schulz-Menger, J., Holmvang, G., Kramer, C. M., Carbone, I., Sechtem, U., Kindermann, I., Gutberlet, M., Cooper, L. T., Liu, P., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.072 · Cited by 2,059
Messroghli, D. R., Moon, J. C., Ferreira, V. M., Grosse-Wortmann, L., He, T., Kellman, P., Mascherbauer, J., Nezafat, R., Salerno, M., Schelbert, E. B., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0389-8 · Cited by 1,727
Improved Detection of Myocardial Involvement in Acute Inflammatory Cardiomyopathies Using T2 Mapping
Thavendiranathan, P., Walls, M., Giri, S., Verhaert, D., Rajagopalan, S., Moore, S., Simonetti, O. P., & Raman, S. V. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.111.967836 · Cited by 324
Self-citationMyocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications
von Knobelsdorff-Brenkenhoff, F., Prothmann, M., Dieringer, M. A., Wassmuth, R., Greiser, A., Schwenke, C., Niendorf, T., & Schulz-Menger, J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-53 · Cited by 265
Metadata
- Authors
- Verhaert, D., Thavendiranathan, P., Giri, S., Mihai, G., Rajagopalan, S., Simonetti, O. P., & Raman, S. V.
- Venue
- JACC: Cardiovascular Imaging
- Publisher
- Elsevier BV
- Published
- 2011-03
- Volume
- 4
- Issue
- 3
- Pages
- 269-278
- ISSN
- 1876-7591 (ISSN-L)
- 1936-878X
- OpenAlex
- W2056044048
- Cited by
- 352
- References
- 16
- FWCI
- 22.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct T2 Quantification of Myocardial Edema in Acute Ischemic Injury. https://app.cochat.ai/papers/10.1016/j.jcmg.2010.09.023
- The paper
- Verhaert, D., Thavendiranathan, P., Giri, S., Mihai, G., Rajagopalan, S., Simonetti, O. P., & Raman, S. V. (2011). Direct T2 Quantification of Myocardial Edema in Acute Ischemic Injury. JACC: Cardiovascular Imaging. https://doi.org/10.1016/j.jcmg.2010.09.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.