Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 259

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Cardiac Magnetic Resonance With T2-Weighted Imaging Improves Detection of Patients With Acute Coronary Syndrome in the Emergency Department

Open access
Cury, Ricardo C., Shash, Khalid, Nagurney, John T., Rosito, Guido, Shapiro, Michael D., Nomura, Cesar H., Abbara, Suhny, Bamberg, Fabian, Ferencik, Maros, Schmidt, Ehud J., Brown, David F., Hoffmann, Udo, Brady, Thomas J. · 2008 · Circulation

Abstract

Background— Cardiac magnetic resonance (CMR) imaging permits early triage of patients presenting to the emergency department with acute chest pain but has been limited by the inability to differentiate new from old myocardial infarction. Our objective was to evaluate a CMR protocol that includes T2-weighted imaging and assessment of left ventricular wall thickness in detecting patients with acute coronary syndrome in the emergency department. Methods and Results— In this prospective cohort observational study, we enrolled patients presenting to the emergency department with acute chest pain, negative cardiac biomarkers, and no ECG changes indicative of acute ischemia. The CMR protocol consisted of T2-weighted imaging, first-pass perfusion, cine function, delayed-enhancement magnetic resonance imaging, and assessment of left ventricular wall thickness. The clinical outcome (acute coronary syndrome) was defined by review of clinical charts by a consensus panel that used American Heart Association/American College of Cardiology guidelines. Among 62 patients, 13 developed acute coronary syndrome during the index hospitalization. The mean CMR time was 32±8 minutes. The new CMR protocol (with the addition of T2-weighted and left ventricular wall thickness) increased the specificity, positive predictive value, and overall accuracy from 84% to 96%, 55% to 85%, and 84% to 93%, respectively, compared with the conventional CMR protocol (cine, perfusion, and delayed-enhancement magnetic resonance imaging). Moreover, in a logistic regression analysis that contained information on clinical risk assessment (c-statistic=0.695) and traditional cardiac risk factors (c-statistic=0.771), the new CMR protocol significantly improved the c-statistic to 0.958 ( P <0.0001). Conclusions— The present study indicates that a new CMR protocol improves the detection of patients with acute coronary syndrome in the emergency department and adds significant value over clinical assessment and traditional cardiac risk factors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.107.740597

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 259

Metadata

Authors
Cury, R. C., Shash, K., Nagurney, J. T., Rosito, G., Shapiro, M. D., Nomura, C. H., Abbara, S., Bamberg, F., Ferencik, M., Schmidt, E. J., Brown, D. F., Hoffmann, U., & Brady, T. J.
Venue
Circulation
Published
2008-08-19
Volume
118
Issue
8
Pages
837-844
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2006128636
Cited by
259
References
17
FWCI
23.42
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Magnetic Resonance With T2-Weighted Imaging Improves Detection of Patients With Acute Coronary Syndrome in the Emergency Department. https://app.cochat.ai/papers/10.1161/circulationaha.107.740597
The paper
Cury, R. C., Shash, K., Nagurney, J. T., Rosito, G., Shapiro, M. D., Nomura, C. H., Abbara, S., Bamberg, F., Ferencik, M., Schmidt, E. J., Brown, D. F., Hoffmann, U., & Brady, T. J. (2008). Cardiac Magnetic Resonance With T2-Weighted Imaging Improves Detection of Patients With Acute Coronary Syndrome in the Emergency Department. Circulation. https://doi.org/10.1161/circulationaha.107.740597

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.