The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Deep Learning for Prediction of Obstructive Disease From Fast Myocardial Perfusion SPECT
Open accessAbstract
Objectives We evaluated the automatic prediction of obstructive disease from myocardial perfusion imaging (MPI) by deep learning as compared to total perfusion deficit (TPD). Background Deep convolutional neural networks trained with large multi-center population may provide improved prediction of per-patient and per-vessel coronary artery disease (CAD) from SPECT MPI. Methods 1638 patients (67% males) without known CAD, undergoing stress 99mTc-sestamibi or tetrofosmin MPI with new generation solid-state scanners in 9 different sites, with invasive coronary angiography performed within 6 months of MPI, were studied. Obstructive disease was defined as ≥ 70% narrowing of coronary arteries (≥ 50% for left main). Left ventricular (LV) myocardium was segmented using clinical nuclear cardiology software and verified by an expert reader. Stress TPD was computed using gender- and camera-specific normal limits. Deep learning was trained using raw and quantitative polar maps and evaluated for prediction of obstructive stenosis in a stratified 10-fold cross validation procedure. Results 1018 (62%) patients and 1797 out of 4914 (37%) arteries had obstructive disease. Area under the receiver operating characteristics curve (AUC) for disease prediction by deep learning was higher than for TPD (per-patient: 0.80 vs. 0.78, per-vessel 0.76 vs. 0.73, P < 0.01). With deep learning threshold set to the same specificity as TPD, per-patient sensitivity improved from 79.8% (TPD) to 82.3% (deep learning) (P < 0.05), and per-vessel sensitivity improved from 64.4% (TPD) to 69.8% (deep learning) (P < 0.01). Conclusions Deep learning has the potential to improve automatic interpretation of MPI as compared to current clinical methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Dermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362
Caffe: Convolutional Architecture for Fast Feature Embedding
Jia, Y., Shelhamer, E., Donahue, J., Karayev, S., Long, J., Girshick, R., Guadarrama, S., & Darrell, T. (2014) · Proceedings of the 22nd ACM international conference on Multimedia · doi:10.1145/2647868.2654889 · Cited by 11,077
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Deep learning in medical image analysis
Shen, D., Wu, G., & Suk, H.-I. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044442 · Cited by 4,968
Greenspan, H., van Ginneken, B., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2553401 · Cited by 1,700
Prediction error estimation: a comparison of resampling methods
Molinaro, A. M., Simon, R., & Pfeiffer, R. M. (2005) · Bioinformatics · doi:10.1093/bioinformatics/bti499 · Cited by 1,339
Angiographic Versus Functional Severity of Coronary Artery Stenoses in the FAME Study
Tonino, P. A. L., Fearon, W. F., De Bruyne, B., Oldroyd, K. G., Leesar, M. A., Ver Lee, P. N., MacCarthy, P. A., van't Veer, M., & Pijls, N. H. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.096 · Cited by 1,271
Artificial Intelligence in Precision Cardiovascular Medicine
Krittanawong, C., Zhang, H., Wang, Z., Aydar, M., & Kitai, T. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.571 · Cited by 1,120
Motwani, M., Dey, D., Berman, D. S., Germano, G., Achenbach, S., Al-Mallah, M. H., Andreini, D., Budoff, M. J., Cademartiri, F., Callister, T. Q., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw188 · Cited by 692
Self-citationNarula, S., Shameer, K., Salem Omar, A. M., Dudley, J. T., & Sengupta, P. P. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.08.062 · Cited by 410
Automated quantification of myocardial perfusion SPECT using simplified normal limits
Slomka, P. J., Nishina, H., Berman, D. S., Akincioglu, C., Abidov, A., Friedman, J. D., Hayes, S. W., & Germano, G. (2005) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2004.10.006 · Cited by 299
Self-citationA Novel High-Sensitivity Rapid-Acquisition Single-Photon Cardiac Imaging Camera
Gambhir, S. S., Berman, D. S., Ziffer, J. A., Nagler, M., Sandler, M. P., Patton, J. A., Hutton, B. F., Sharir, T., Haim, S. B., & Ben‐Haim, S. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.060020 · Cited by 266
Self-citationPrognostic Value of Combined Clinical and Myocardial Perfusion Imaging Data Using Machine Learning
Betancur, J., Otaki, Y., Motwani, M., Fish, M. B., Lemley, M., Dey, D., Gransar, H., Tamarappoo, B., Germano, G., Sharir, T., et al. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.07.024 · Cited by 230
Self-citationEffects of Radiation Exposure From Cardiac Imaging
Einstein, A. J. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.079 · Cited by 215
Self-citationSengupta, P. P., Huang, Y.-M., Bansal, M., Ashrafi, A., Fisher, M., Shameer, K., Gall, W., & Dudley, J. T. (2016) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.115.004330 · Cited by 203
Arsanjani, R., Xu, Y. X., Dey, D., Vahistha, V., Shaleṿ, A., Nakanishi, R., Hayes, S. W., Fish, M. B., Berman, D. S., Germano, G., et al. (2013) · Journal of Nuclear Cardiology · doi:10.1007/s12350-013-9706-2 · Cited by 143
Self-citationNakazato, R., Tamarappoo, B. K., Kang, X., Wolak, A., Kite, F., Hayes, S. W., Thomson, L., Friedman, J. D., Berman, D. S., & Slomka, P. J. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.078782 · Cited by 142
Self-citationArsanjani, R., Dey, D., Khachatryan, T., Shaleṿ, A., Hayes, S. W., Fish, M. B., Nakanishi, R., Germano, G., Berman, D. S., & Slomka, P. J. (2014) · Journal of Nuclear Cardiology · doi:10.1007/s12350-014-0027-x · Cited by 139
Self-citationArsanjani, R., Xu, Y. X., Hayes, S. W., Fish, M. B., Lemley, M. H., Gerlach, J., Dorbala, S., Berman, D. S., Germano, G., & Slomka, P. J. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.108969 · Cited by 114
Self-citationComparative Study of Caffe, Neon, Theano, and Torch for Deep LearningPreprint
Bahrampour, S., Ramakrishnan, N., Schott, L., & Shah, M. (2015) · arXiv (Cornell University) · Cited by 102
Betancur, J., Rubeaux, M., Fuchs, T. A., Otaki, Y., Arnson, Y., Slipczuk, L. N., Benz, D. C., Germano, G., Dey, D., Lin, C., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.179911 · Cited by 68
Self-citationAutomated Quality Control for Segmentation of Myocardial Perfusion SPECT
Xu, Y. X., Kavanagh, P., Fish, M. B., et al. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.061333 · Cited by 56
Self-citationMachine Learning for Echocardiographic Imaging
Tajik, A. J. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.09.915 · Cited by 46
Deep Learning With Unsupervised Feature in Echocardiographic Imaging
Krittanawong, C., Tunhasiriwet, A., Zhang, H., Wang, Z., Aydar, M., & Kitai, T. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.12.047 · Cited by 31
Narula, S., Shameer, K., Omar, A. M. S., Dudley, J. T., & Sengupta, P. P. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.01.062 · Cited by 13
Cited by
Artificial Intelligence in Cardiovascular Imaging
Dey, D., Slomka, P. J., Leeson, P., Comaniciu, D., Shrestha, S., Sengupta, P. P., & Marwick, T. H. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.054 · Cited by 680
Self-citationAl’Aref, S. J., Anchouche, K., Singh, G., Slomka, P. J., Kolli, K. K., Kumar, A., Pandey, M., Maliakal, G., van Rosendael, A. R., Beecy, A. N., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy404 · Cited by 534
Self-citationArtificial intelligence in medical education
Masters, K. (2019) · Medical Teacher · doi:10.1080/0142159x.2019.1595557 · Cited by 469
Deep learning for cardiovascular medicine: a practical primer
Krittanawong, C., Johnson, K. W., Rosenson, R. S., Wang, Z., Aydar, M., Baber, U., Min, J. K., Tang, W. H. W., Halperin, J. L., & Narayan, S. M. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz056 · Cited by 435
State-of-the-Art Deep Learning in Cardiovascular Image Analysis
Litjens, G., Ciompi, F., Wolterink, J. M., de Vos, B. D., Leiner, T., Teuwen, J., & Išgum, I. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.06.009 · Cited by 388
Metadata
- Authors
- Betancur, J., Commandeur, F., Motlagh, M., Sharir, T., Einstein, A. J., Bokhari, S., Fish, M. B., Ruddy, T. D., Kaufmann, P., Sinusas, A. J., Miller, E. J., Bateman, T. M., Dorbala, S., Di Carli, M., Germano, G., Otaki, Y., Tamarappoo, B. K., Dey, D., Berman, D. S., & Slomka, P. J.
- Venue
- JACC: Cardiovascular Imaging
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 11
- Issue
- 11
- Pages
- 1654-1663
- ISSN
- 1876-7591 (ISSN-L)
- 1936-878X
- OpenAlex
- W2789532252
- Cited by
- 358
- References
- 29
- FWCI
- 25.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.