Intravital microscopy reveals a novel mechanism of nanoparticles excretion in kidney
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Developing nanocarriers that accumulate in targeted organs and are harmlessly eliminated still remains a big challenge. Nanoparticles (NP) biodistribution is governed by their size, composition, surface charge and coverage. The current thinking in bionanotechnology is that renal clearance is limited by glomerular basement membrane pore size (≈6 nm), although there is a growing evidence that NP exceeding the threshold can also be excreted with urine. Here we compare biodistribution of PEGylated 140 nm iron oxide cubes and clusters with a special focus on renal accumulation and excretion. Atomic emission spectroscopy, fluorescent microscopy and magnetic resonance imaging revealed rapid and transient accumulation of magnetic NP in kidney. Using intravital microscopy we tracked in real time NP translocation from peritubular capillaries to basal compartment of tubular cells and subsequent excretion to the lumen within 60 min after systemic administration. Transmission electron microscopy revealed persistence of intact full-sized NP in urine 2 h post injection. The results suggest that translocation through peritubular endothelium to tubular epithelial cells is an alternative mechanism of renal clearance enabling excretion of NP above glomerular cut-off size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Cited by
Organ-specific toxicity of magnetic iron oxide-based nanoparticles
Chrishtop, V. V., Mironov, V. A., Prilepskii, A. Y., Nikonorova, V. G., & Vinogradov, V. V. (2021) · Nanotoxicology · doi:10.1080/17435390.2020.1842934 · Cited by 86
Nanoparticle delivery in vivo: A fresh look from intravital imaging
Lin, Q., Fathi, P., & Chen, X. (2020) · eBioMedicine · doi:10.1016/j.ebiom.2020.102958 · Cited by 48
“The results suggest that translocation through the peritubular endothelium to tubular epithelial cells is an alternative mechanism of renal clearance, enabling excretion of NPs above the glomerular cut-off size [48].”
BackgroundWang, K., Yang, R., Li, J., Wang, H., Wan, L., & He, J. (2025) · Frontiers in Pharmacology · doi:10.3389/fphar.2025.1591438 · Cited by 27
Metadata
- Authors
- Naumenko, V., Nikitin, A., Kapitanova, K., Melnikov, P., Vodopyanov, S., Garanina, A., Valikhov, M., Ilyasov, A., Vishnevskiy, D., Markov, A., Golyshev, S., Zhukov, D., Alieva, I., Abakumov, M., Chekhonin, V., & Majouga, A.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 307
- Pages
- 368-378
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2955074241
- Cited by
- 76
- References
- 1
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intravital microscopy reveals a novel mechanism of nanoparticles excretion in kidney. https://app.cochat.ai/papers/10.1016/j.jconrel.2019.06.026
- The paper
- Naumenko, V., Nikitin, A., Kapitanova, K., Melnikov, P., Vodopyanov, S., Garanina, A., Valikhov, M., Ilyasov, A., Vishnevskiy, D., Markov, A., Golyshev, S., Zhukov, D., Alieva, I., Abakumov, M., Chekhonin, V., & Majouga, A. (2019). Intravital microscopy reveals a novel mechanism of nanoparticles excretion in kidney. Journal of Controlled Release. https://doi.org/10.1016/j.jconrel.2019.06.026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.