The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Mechanism of a long-term controlled drug release system based on simple blended electrospun fibers
Open accessAbstract
BACKGROUND: Drug delivery systems based on electrospun fibers have been under development for many years. However, studies of controllable long-term drug release from electrospun membrane systems and the underlying release mechanisms have seldom been reported. METHODS: In this study, electrospun membrane drug delivery systems consisting of the antibiotic ciprofloxacin hydrochloride and FDA-approved polymers are fabricated. Different second-component polymers are introduced to change the properties of a poly(d,l-lactide-co-glycolide) (PLGA) matrix, thereby altering the drug release behavior. On the basis of observations of morphology, cumulative release profiles, and determinations of release duration, the drug release kinetics and critical characteristics influencing drug release behavior are discussed. RESULTS: It is found that the drug release profiles can be divided into three stages according to the rate of drug release. Stage I is controlled by fiber swelling and diffusion according to Fick's second law. Stage II is controlled by diffusion through a fused membrane structure, which results in very slow drug release. Stage III is controlled by polymer degradation and involves release of the remaining drug. CONCLUSIONS: The results of this study of release mechanisms should provide a basis for adjustments of drug release dosage and duration, thereby contributing to the development of drug delivery systems satisfying clinical requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bio-resorbable polymer stents: a review of material progress and prospects
McMahon, S., Bertollo, N., Cearbhaill, E. D. O., Salber, J., Pierucci, L., Duffy, P., Dürig, T., Bi, V., & Wang, W. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.05.002 · Cited by 194
Cited by
Electrospinning for drug delivery applications: A review
Luraghi, A., Peri, F., & Moroni, L. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.03.033 · Cited by 746
The Bioavailability of Drugs—The Current State of Knowledge
Stielow, M., Witczyńska, A., Kubryń, N., Fijałkowski, Ł., Nowaczyk, J., & Nowaczyk, A. (2023) · Molecules · doi:10.3390/molecules28248038 · Cited by 391
Electrospun Medicated Nanofibers for Wound Healing: Review
Liu, X., Xu, H., Zhang, M., & Yu, D.-G. (2021) · Membranes · doi:10.3390/membranes11100770 · Cited by 311
Macartney, R. A., Weaver, E., Irwin, R., Wylie, M. P., Burke, G. A., & Lamprou, D. A. (2024) · Biomaterials Advances · doi:10.1016/j.bioadv.2024.213765 · Cited by 19
Metadata
- Authors
- Wu, J., Zhang, Z., Gu, J., Zhou, W., Liang, X., Zhou, G., Han, C. C., Xu, S., & Liu, Y.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 320
- Pages
- 337-346
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2999768730
- Cited by
- 227
- References
- 1
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.