Observational study of patient-ventilator asynchrony and relationship to sedation level
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Purpose Clinicians frequently administer sedation to facilitate mechanical ventilation. The purpose of this study was to examine the relationship between sedation level and patient-ventilator asynchrony. Materials and Methods Airway pressure and airflow were recorded for 15 minutes. Patient-ventilator asynchrony was assessed by determining the number of breaths demonstrating ineffective triggering, double triggering, short cycling, and prolonged cycling. Ineffective triggering index (ITI) was calculated by dividing the number of ineffectively triggered breaths by the total number of breaths (triggered and ineffectively triggered). Sedation level was assessed by 3 methods: Richmond Agitation-Sedation Scale (RASS), awake (yes or no), and delirium (CAM-ICU). Results Twenty medical intensive care unit patients underwent 35 observations. Ineffective triggering was seen in 17 of 20 patients and was the most frequent asynchrony (88% of all asynchronous breaths), being observed in 9 ± 12% of breaths. Deeper levels of sedation were associated with increasing ITI (Awake: yes 2% versus no 11% p = 0.05; CAM-ICU: coma 15% versus delirium 5% versus no delirium 2%, p < 0.05; RASS: 0, 0% versus −5, 15%, p < 0.05). Diagnosis of chronic obstructive pulmonary disease, sedative type or dose, mechanical ventilation mode, trigger method had no effect on ITI. Conclusions Asynchrony is common, and deeper sedation level is a predictor of ineffective triggering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376 · cited 1×
“Other Variables Baseline characteristics of age, gender, race, ethnicity, reason for mechanical ventilation, severity of illness as measured by Acute Physiology and Chronic Health Evaluation II (APACHE II) were recorded.(14) History of COPD was ascertained by interviewing the attending physician caring for the patient…”
MethodVincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674 · cited 1×
“Severity of illness using the Sequential Organ Failure Assessment (SOFA) was ascertained for the 24 hour period prior to asynchrony determination.(15) Total amount of sedation administered in the 24 hour period prior to sedation evaluation was recorded, as was the duration of continuous intravenous infusion.”
MethodAPACHE II: a severity of disease classification system.
Knaus, W. A., Draper, E. S., Wagner, D. P., & Zimmerman, J. E. (1985) · PubMed · Cited by 6,034
Sessler, C. N., Gosnell, M. S., Grap, M. J., Brophy, G. M., O'Neal, P. V., Keane, K. A., Tesoro, E. P., & Elswick, R. K. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2107138 · Cited by 3,695 · cited 1×
“Assessment of sedation level consisted of obtaining a clinical sedation and agitation score (Richmond Agitation-Sedation Scale, RASS), a delirium evaluation (Confusion Assessment Method for the Intensive Care Unit, CAM-ICU) and determination of awake (yes or no, as defined by Kress et al in a study to evaluate the eff…”
MethodEly, E. W., Inouye, S. K., Bernard, G. R., Gordon, S., Francis, J., May, L., Truman, B., Speroff, T., Gautam, S., Margolin, R., et al. (2001) · JAMA · doi:10.1001/jama.286.21.2703 · Cited by 3,210 · cited 2×
“Assessment of sedation level consisted of obtaining a clinical sedation and agitation score (Richmond Agitation-Sedation Scale, RASS), a delirium evaluation (Confusion Assessment Method for the Intensive Care Unit, CAM-ICU) and determination of awake (yes or no, as defined by Kress et al in a study to evaluate the eff…”
MethodKress, J. P., Pohlman, A. S., O'Connor, M. F., & Hall, J. B. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422002 · Cited by 2,981 · cited 2×
“Assessment of sedation level consisted of obtaining a clinical sedation and agitation score (Richmond Agitation-Sedation Scale, RASS), a delirium evaluation (Confusion Assessment Method for the Intensive Care Unit, CAM-ICU) and determination of awake (yes or no, as defined by Kress et al in a study to evaluate the eff…”
MethodPatient-ventilator asynchrony during assisted mechanical ventilation
Thille, A. W., Rodriguez, P., Cabello, B., Lellouche, F., & Brochard, L. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0301-8 · Cited by 930
Comparison of assisted ventilator modes on triggering, patient effort, and dyspnea.
Leung, P., Jubran, A., & Tobin, M. J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.6.9196100 · Cited by 420 · cited 6×
“(5,7) Therefore, we may not have had the power to detect COPD as a marker of ineffective triggering.”
BackgroundResultInfluentialPatient-Ventilator Trigger Asynchrony in Prolonged Mechanical Ventilation
Chao, D. C., Scheinhorn, D. J., & Stearn-Hassenpflug, M. (1997) · Chest · doi:10.1378/chest.112.6.1592 · Cited by 322 · cited 8×
“(5,7) Therefore, we may not have had the power to detect COPD as a marker of ineffective triggering.”
BackgroundInfluential
Cited by
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
Asynchronies during mechanical ventilation are associated with mortality
Blanch, L., Villagra, A., Sales, B., Montanya, J., Lucangelo, U., Luján, M., García-Esquirol, O., Chacón, E., Estruga, A., Oliva, J. C., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3692-6 · Cited by 539
Mechanical Ventilation: State of the Art
Pham, T., Brochard, L. J., & Slutsky, A. S. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.05.004 · Cited by 377
Beitler, J. R., Sands, S. A., Loring, S. H., Owens, R. L., Malhotra, A., Spragg, R. G., Matthay, M. A., Thompson, B. T., & Talmor, D. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4423-3 · Cited by 206
“” Several subsequent investigations have adopted the Thille definition [7, 17, 18], although it too has limitations when applied to BSD.”
BackgroundClusters of ineffective efforts during mechanical ventilation: impact on outcome
Vaporidi, K., Babalis, D., Chytas, A., Lilitsis, E., Kondili, E., Amargianitakis, V., Chouvarda, I., Maglaveras, N., & Georgopoulos, D. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4593-z · Cited by 184
Chanques, G., Kress, J. P., Pohlman, A., Patel, S., Poston, J., Jaber, S., & Hall, J. B. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828c2d7a · Cited by 183
Blanch, L., Sales, B., Montanya, J., Lucangelo, U., Garcia-Esquirol, O., Villagra, A., Chacon, E., Estruga, A., Borelli, M., Burgueño, M. J., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2493-4 · Cited by 158
Metadata
- Authors
- de Wit, M., Pedram, S., Best, A. M., & Epstein, S. K.
- Venue
- Journal of Critical Care
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 24
- Issue
- 1
- Pages
- 74-80
- ISSN
- 0883-9441 (ISSN-L)
- OpenAlex
- W2163175535
- Cited by
- 199
- References
- 19
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.