Catquest-9SF patient outcomes questionnaire: Nine-item short-form Rasch-scaled revision of the Catquest questionnaire
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess and optimize the Catquest questionnaire for measuring patient-reported outcomes of cataract surgery using Rasch analysis. SETTING: Fifty-eight ophthalmic surgical units in Sweden. METHODS: Catquest questionnaires (n = 21364) from the Swedish National Cataract Register were selected and randomized to 2 groups. Data from 10486 questionnaires were comprehensively Rasch analyzed using a 4-Andrich rating scale model in Winsteps software. A revised version of Catquest was developed (Catquest-9SF) and tested in 10886 patients for validity and responsiveness to cataract surgery. RESULTS: Only the visual disability subscale formed a valid measurement scale. This could be enhanced through the addition of the 2 global assessment items; however, the symptoms and frequency of performing the activities items did not contribute to the measurement. The 9-item short-form version (Catquest-9SF) had ordered response thresholds and good person separation (2.65) and was largely free from differential item functioning. All items fit a single overall construct (infit range, 0.75 to 1.29; outfit range, 0.70 to 1.39) and unidimensional by principal components analysis. The items were well targeted to the preoperative participants (0.34 logit difference in means). The score correlated with visual acuity (r = 0.43 preoperatively; r = 0.48 postoperatively) and was highly responsive to cataract surgery (preoperatively -0.32 +/- 2.15 logits; postoperatively -3.21 +/- 2.50 logits (P<.0001). CONCLUSIONS: The 9-item Rasch-scaled Catquest-9SF was highly valid in measuring visual disability outcomes of cataract surgery. Its brevity makes it suited to routine clinical use, and a raw-data to Rasch-measure conversion simplifies application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quality criteria were proposed for measurement properties of health status questionnaires
Terwee, C. B., Bot, S. D. M., de Boer, M. R., van der Windt, D. A. W. M., Knol, D. L., Dekker, J., Bouter, L. M., & de Vet, H. C. W. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.03.012 · Cited by 10,764 · cited 1×
“The importance of Rasch analysis in the development and scoring of questionnaires has been recognized in standards proposed for the assessment of questionnaire quality.(16,45,46) Numerous calls have been made in ophthalmology for the development of instruments using this technology.”
Probabilistic Models for Some Intelligence and Attainment Tests
(1961) · Information and Control · doi:10.1016/s0019-9958(61)80061-2 · Cited by 6,939
International Classification of Functioning, Disability and Health
Chard, G. (2004) · British Journal of Occupational Therapy · doi:10.1177/030802260406700101 · Cited by 3,688
A Rating Formulation for Ordered Response Categories
Andrich, D. (1978) · Psychometrika · doi:10.1007/bf02293814 · Cited by 2,970
Methods for assessing responsiveness
Husted, J. A., Cook, R. J., Farewell, V. T., & Gladman, D. D. (2000) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(99)00206-1 · Cited by 1,471 · cited 1×
“80 or above are large.(44) The good characteristics of Catquest-9SF have led to its incorporation in the SwedishNationalCataract Register.”
BackgroundThe VF-14: An Index of Functional Impairment in Patients With Cataract
Steinberg, E. P. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090170074026 · Cited by 960
Observations are always ordinal; measurements, however, must be interval.
Wright, B., & Linacre, J. M. (1989) · PubMed · Cited by 679
Development of the Activities of Daily Vision Scale: A Measure of Visual Functional Status
Mangione, C. M., Phillips, R. S., Seddon, J. M., Lawrence, M. G., Cook, E. F., Dailey, R., & Goldman, L. (1992) · Medical Care · doi:10.1097/00005650-199212000-00004 · Cited by 539
Objective measurement : theory into practice
Wilson, M. R., Engelhard, G., & Draney, K. (1992) · Ablex Pub. Corp. eBooks · Cited by 454
Walters, S. J., & Brazier, J. E. (2003) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-1-4 · Cited by 441
The Development, Assessment, and Selection of Questionnaires
PESUDOVS, K., BURR, J. M., HARLEY, C., & ELLIOTT, D. B. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e318141fe75 · Cited by 403 · cited 2×
“The importance of Rasch analysis in the development and scoring of questionnaires has been recognized in standards proposed for the assessment of questionnaire quality.(16,45,46) Numerous calls have been made in ophthalmology for the development of instruments using this technology.”
MethodSelf-citationPsychometric properties of vision‐related quality of life questionnaires: a systematic review
De Boer, M. R., Moll, A. C., De Vet, H. C. W., Terwee, C. B., Völker‐Dieben, H. J. M., & Van Rens, G. H. M. B. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00187.x · Cited by 263 · cited 1×
“The importance of Rasch analysis in the development and scoring of questionnaires has been recognized in standards proposed for the assessment of questionnaire quality.(16,45,46) Numerous calls have been made in ophthalmology for the development of instruments using this technology.”
The Quality of Life Impact of Refractive Correction (QIRC) Questionnaire: Development and Validation
Pesudovs, K., Garamendi, E., & Elliott, D. B. (2004) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2004.tb01962.x · Cited by 242
Self-citationLamoureux, E. L., Pallant, J. F., Pesudovs, K., Hassell, J. B., & Keeffe, J. E. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0220 · Cited by 227
Self-citationThe Swedish National Cataract Register: A 9‐year review
Lundström, M., Stenevi, U., & Thorburn, W. (2002) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.2002.800304.x · Cited by 203 · cited 2×
“The Catquest has been used in the Swedish National Cataract Register since 1995.(9) The participating surgical units have, on a voluntary basis during 1 month each year, used the questionnaire on all patients having cataract surgery during that month.”
MethodSelf-citationEvaluation of Quality of Life for Patients With Glaucoma
Spaeth, G., Walt, J., & Keener, J. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.07.075 · Cited by 185 · cited 1×
“Numerous calls have been made in ophthalmology for the development of instruments using this technology.(11,47,48) Clearly, a Rasch-scaled questionnaire should be usedwherever possible for the measurement of outcomes.”
MethodPesudovs, K., Garamendi, E., Keeves, J. P., & Elliott, D. B. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1075 · Cited by 183 · cited 2×
“In this study, we applied Rasch analysis to a database of Catquest questionnaires completed before and after cataract surgery.(7) The purpose was to assess and reengineer the Catquest questionnaire using Rasch analysis to optimize item fit to the construct, minimize test length, and create a linear measure of visual d…”
MethodSelf-citationMassof, R. W., & Fletcher, D. C. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00249-2 · Cited by 176 · cited 1×
“This finding is consistent with research of quality-of-life instruments in which symptoms and disability failed to tap the same latent trait.(18,36) As described previously, the evaluation of original Catquest was made using a decision tree.”
ResultInternational Applicability of the VF-14
Alonso, J., Espallargues, M., Andersen, T. F., Cassard, S. D., Dunn, E., Bernth-Petersen, P., Norregaard, J. C., Black, C., Steinberg, E. P., & Anderson, G. F. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30230-9 · Cited by 176 · cited 2×
“This is consistent with findings in other studies that show that better-eye visual acuity correlates best with visual disability measurement.41 Moreover, the correlations with visual acuity here are higher than for most questionnaires, which is likely due to the high precision of the Catquest-9SF.42,43 The Catquest-9S…”
ResultComparing Alternative Rasch-Based Methods vs Raw Scores in Measuring Change in Health
Norquist, J. M., Fitzpatrick, R., Dawson, J., & Jenkinson, C. (2004) · Medical Care · doi:10.1097/01.mlr.0000103530.13056.88 · Cited by 157 · cited 2×
“Clearly, this results in more meaningful interpretation of scoring and also reduces the sample size required to find significant differences in clinical outcome studies.(14,15) The finding that the frequency items did not contribute to themeasurement of disabilitywas not consistent with the theory behind the inclusion…”
MethodResultEvaluating cataract surgery gains by assessing patients' quality of life using the VF-7
Uusitalo, R. J., Brans, T., Pessi, T., & Tarkkanen, A. H. A. (1999) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(99)00082-6 · Cited by 122 · cited 1×
“Developing shorter questionnaires for broader implementation of patient-reported outcomes measurements is an often-pursued aim.(6,38,39) However, Rasch analysis has shown limitations in these questionnaires.”
BackgroundA Comparison of the Separation Ratio and Coefficient α in the Creation of Minimum Item Sets
Mallinson, T., Stelmack, J. A., & Velozo, C. A. (2003) · Medical Care · doi:10.1097/01.mlr.0000103522.78233.c3 · Cited by 122 · cited 3×
“It is difficult to have satisfactory measurement precision with a small number of items.(6) Attempts to create short-form questionnaires from existing questionnaires has arrived at minimum item sets of 12 items for the VDA, 16 items for the ADVS, and 10 items for the VF-14 (Pesudovs K, et al.”
BackgroundMethodGaramendi, E., Pesudovs, K., Stevens, M. J., & Elliott, D. B. (2005) · Vision Research · doi:10.1016/j.visres.2005.07.007 · Cited by 121 · cited 2×
“Clearly, this results in more meaningful interpretation of scoring and also reduces the sample size required to find significant differences in clinical outcome studies.(14,15) The finding that the frequency items did not contribute to themeasurement of disabilitywas not consistent with the theory behind the inclusion…”
MethodResultSelf-citationPatient-centred measurement in ophthalmology – a paradigm shift
Pesudovs, K. (2006) · BMC Ophthalmology · doi:10.1186/1471-2415-6-25 · Cited by 111 · cited 2×
“Modern test theory, including Rasch analysis, has shown the invalidity of summary scoring and resolves the problem by providing linear interval transformation of the ordinal raw score, thereby permitting the use of parametric statistical techniques on the questionnaire data.(11,14,15) Other unique evaluations availabl…”
MethodSelf-citationBenefit to patients of bilateral same-day cataract extraction: Randomized clinical study
Lundström, M., Albrecht, S., Nilsson, M., & Åström, B. (2006) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2006.01.075 · Cited by 106
Self-citationSmith, R. M. (1986) · Educational and Psychological Measurement · doi:10.1177/001316448604600210 · Cited by 102 · cited 1×
“30 represent misfit with at least 30% more variance than would be expected and suggests that the itemmeasures something different than the overall scale.(29) Unidimensionality provides further evidence that the instrument ismeasuring the underlying trait (visual disability).”
BackgroundThe Contact Lens Impact on Quality of Life (CLIQ) Questionnaire: Development and Validation
Pesudovs, K., Garamendi, E., & Elliott, D. B. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0933 · Cited by 83 · cited 1×
“The Rasch analysis technique has also been used to construct new questionnaires.(18,19) In this study, we applied Rasch analysis to a database of Catquest questionnaires completed before and after cataract surgery.”
MethodSelf-citationEquating the MOS SF36 and the LSU HSI Physical Functioning Scales.
Fisher, W. P., Eubanks, R. L., & Marier, R. L. (1997) · PubMed · Cited by 64
Mitchell, J., Wolffsohn, J. S., Woodcock, A. J., Anderson, S. J., ffytche, T. J., Rubinstein, M., Amoaku, W. M. K., & Bradley, C. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.04.031 · Cited by 51 · cited 1×
“This is consistent with findings in other studies that show that better-eye visual acuity correlates best with visual disability measurement.(41) Moreover, the correlations with visual acuity here are higher than for most questionnaires, which is likely due to the high precision of the Catquest-9SF.”
ResultAssessment of vision-related quality of life measures in ophthalmic conditions
Lundström, M., & Wendel, E. (2006) · Expert Review of Pharmacoeconomics & Outcomes Research · doi:10.1586/14737167.6.6.691 · Cited by 11 · cited 1×
“Clearly, a Rasch-scaled questionnaire should be usedwherever possible for the measurement of outcomes.(48,49) The Catquest-9SF, along with the Cataract Outcomes Questionnaire, represent the state of the art for the measurement of visual disability, and is likely superior to the Rasch-analyzed versions of the ADVS and…”
MethodSelf-citation
Cited by
Seguí, M. D. M., Cabrero-García, J., Crespo, A., Verdú, J., & Ronda, E. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2015.01.015 · Cited by 398
Cataract in the Adult Eye Preferred Practice Pattern®
Olson, R. J., Braga-Mele, R., Chen, S. H., Miller, K. M., Pineda, R., Tweeten, J. P., & Musch, D. C. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.09.027 · Cited by 277
One million cataract surgeries: Swedish National Cataract Register 1992–2009
Behndig, A., Montan, P., Stenevi, U., Kugelberg, M., & Lundström, M. (2011) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.05.021 · Cited by 267
Self-citationRemediating serious flaws in the National Eye Institute Visual Function Questionnaire
Pesudovs, K., Gothwal, V. K., Wright, T., & Lamoureux, E. L. (2010) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2009.11.019 · Cited by 212
Self-citationDevelopment of a Short Version of MSQOL-54 Using Factor Analysis and Item Response Theory
Rosato, R., Testa, S., Bertolotto, A., Confalonieri, P., Patti, F., Lugaresi, A., Grasso, M. G., Toscano, A., Giordano, A., & Solari, A. (2016) · PLOS ONE · doi:10.1371/journal.pone.0153466 · Cited by 46
Metadata
- Authors
- Lundström, M., & Pesudovs, K.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2009-03
- Volume
- 35
- Issue
- 3
- Pages
- 504-513
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2171645801
- Cited by
- 252
- References
- 30
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.