Remediating serious flaws in the National Eye Institute Visual Function Questionnaire
The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
PURPOSE: To test the assumption that the National Eye Institute Visual Function Questionnaire (NEI VFQ) measures visual functioning, assess the validity of its subscales, and, if flawed, revise the questionnaire and derive a shortened version with sound psychometric properties. SETTING: Flinders Medical Centre, Adelaide, Australia. METHODS: Patients from the cataract surgery waiting list self-administered and completed the 39-item NEI VFQ (NEI VFQ-39). Rasch analysis was applied, and the psychometric performance of the entire questionnaire and each subscale was tested. Instrument revision was performed in the context of Rasch analysis statistics. RESULTS: Five hundred thirty-six patients (mean age 73.8 years) completed the questionnaire. Response categories for 2 question types were not used as intended so dysfunctional categories were combined. The NEI VFQ-39 and the 25-item version (NEI VFQ-25) had good precision but evidence of multidimensionality (more than 1 construct in 1 score), questions that did not fit the construct, suboptimum targeting of item difficulty to person ability, and dysfunctional subscales (8 NEI VFQ-39; 12 NEI VFQ-25). Questions could be reorganized into 2 constructs (a visual functioning scale and a socioemotional scale) that, after misfitting questions were removed, gave valid measurement of each construct and preserved 3 subscales. Removing redundancy from these long-form subscales yielded valid short-form scales. CONCLUSIONS: Several NEI VFQ subscales were not psychometrically sound; as an overall measure, it is flawed by multidimensionality. This was repaired by segregation into visual functioning and socioemotional scales. Valid long and short forms of the scales could enhance application of the questionnaire.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applying the Rasch Model: Fundamental Measurement in the Human Sciences
Bond, T. G., & Fox, C. M. (2003) · Journal of Educational Measurement · doi:10.1111/j.1745-3984.2003.tb01103.x · Cited by 4,492
A Rating Formulation for Ordered Response Categories
Andrich, D. (1978) · Psychometrika · doi:10.1007/bf02293814 · Cited by 2,970
Development of the 25-list-item National Eye Institute Visual Function Questionnaire
Mangione, C. M. (2001) · Archives of Ophthalmology · doi:10.1001/archopht.119.7.1050 · Cited by 2,230
Reasonable mean-square fit values
Wright, B. G. (1994) · Medical Entomology and Zoology · Cited by 1,743
Optimizing rating scale category effectiveness.
Linacre, J. M. (2002) · PubMed · Cited by 1,689
Rating Scale Analysis: Rasch Measurement
Wolins, L., Wright, B. D., & Masters, G. N. (1983) · Journal of the American Statistical Association · doi:10.2307/2288670 · Cited by 1,029
(2002) · PubMed · Cited by 953
Duncan, P. W., Bode, R. K., Min Lai, S., & Perera, S. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(03)00035-2 · Cited by 908 · cited 1×
“9 indicates 4 strata.(48) A person separation reliability of 0.”
BackgroundPsychometric Properties of the National Eye Institute Visual Function Questionnaire (NEI-VFQ)
Mangione, C. M. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.11.1496 · Cited by 848
Observations are always ordinal; measurements, however, must be interval.
Wright, B., & Linacre, J. M. (1989) · PubMed · Cited by 679
Cited by
Social and emotional impact of diabetic retinopathy: a review
Fenwick, E., Rees, G., Pesudovs, K., Dirani, M., Kawasaki, R., Wong, T. Y., & Lamoureux, E. (2012) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2011.02599.x · Cited by 156
Self-citation
Metadata
- Authors
- Pesudovs, K., Gothwal, V. K., Wright, T., & Lamoureux, E. L.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2010-05
- Volume
- 36
- Issue
- 5
- Pages
- 718-732
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2123007530
- Cited by
- 212
- References
- 60
- FWCI
- 20.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Remediating serious flaws in the National Eye Institute Visual Function Questionnaire. https://app.cochat.ai/papers/10.1016/j.jcrs.2009.11.019
- The paper
- Pesudovs, K., Gothwal, V. K., Wright, T., & Lamoureux, E. L. (2010). Remediating serious flaws in the National Eye Institute Visual Function Questionnaire. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2009.11.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.