Remediating serious flaws in the National Eye Institute Visual Function Questionnaire
The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
PURPOSE: To test the assumption that the National Eye Institute Visual Function Questionnaire (NEI VFQ) measures visual functioning, assess the validity of its subscales, and, if flawed, revise the questionnaire and derive a shortened version with sound psychometric properties. SETTING: Flinders Medical Centre, Adelaide, Australia. METHODS: Patients from the cataract surgery waiting list self-administered and completed the 39-item NEI VFQ (NEI VFQ-39). Rasch analysis was applied, and the psychometric performance of the entire questionnaire and each subscale was tested. Instrument revision was performed in the context of Rasch analysis statistics. RESULTS: Five hundred thirty-six patients (mean age 73.8 years) completed the questionnaire. Response categories for 2 question types were not used as intended so dysfunctional categories were combined. The NEI VFQ-39 and the 25-item version (NEI VFQ-25) had good precision but evidence of multidimensionality (more than 1 construct in 1 score), questions that did not fit the construct, suboptimum targeting of item difficulty to person ability, and dysfunctional subscales (8 NEI VFQ-39; 12 NEI VFQ-25). Questions could be reorganized into 2 constructs (a visual functioning scale and a socioemotional scale) that, after misfitting questions were removed, gave valid measurement of each construct and preserved 3 subscales. Removing redundancy from these long-form subscales yielded valid short-form scales. CONCLUSIONS: Several NEI VFQ subscales were not psychometrically sound; as an overall measure, it is flawed by multidimensionality. This was repaired by segregation into visual functioning and socioemotional scales. Valid long and short forms of the scales could enhance application of the questionnaire.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applying the Rasch Model: Fundamental Measurement in the Human Sciences
Bond, T. G., & Fox, C. M. (2003) · Journal of Educational Measurement · doi:10.1111/j.1745-3984.2003.tb01103.x · Cited by 4,492
A Rating Formulation for Ordered Response Categories
Andrich, D. (1978) · Psychometrika · doi:10.1007/bf02293814 · Cited by 2,970
Development of the 25-list-item National Eye Institute Visual Function Questionnaire
Mangione, C. M. (2001) · Archives of Ophthalmology · doi:10.1001/archopht.119.7.1050 · Cited by 2,230
Reasonable mean-square fit values
Wright, B. G. (1994) · Medical Entomology and Zoology · Cited by 1,743
Optimizing rating scale category effectiveness.
Linacre, J. M. (2002) · PubMed · Cited by 1,689
Rating Scale Analysis: Rasch Measurement
Wolins, L., Wright, B. D., & Masters, G. N. (1983) · Journal of the American Statistical Association · doi:10.2307/2288670 · Cited by 1,029
(2002) · PubMed · Cited by 953
Duncan, P. W., Bode, R. K., Min Lai, S., & Perera, S. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(03)00035-2 · Cited by 908 · cited 1×
“9 indicates 4 strata.(48) A person separation reliability of 0.”
BackgroundPsychometric Properties of the National Eye Institute Visual Function Questionnaire (NEI-VFQ)
Mangione, C. M. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.11.1496 · Cited by 848
Observations are always ordinal; measurements, however, must be interval.
Wright, B., & Linacre, J. M. (1989) · PubMed · Cited by 679
Care Patterns in Medicare and Their Implications for Pay for Performance
Pham, H. H., Schrag, D., O'Malley, A. S., Wu, B., & Bach, P. B. (2007) · New England Journal of Medicine · doi:10.1056/nejmsa063979 · Cited by 511
Mangione, C. M., Berry, S., Spritzer, K., Janz, N. K., Klein, R., Owsley, C., & Lee, P. P. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.2.227 · Cited by 486 · cited 2×
“These new items would probably have to be sought from patient focus groups, although it is possible that some items from the 51-item field test version of the NEI VFQ could help.(41) Poor targeting may also be sample dependent.”
BackgroundMethodThe Development, Assessment, and Selection of Questionnaires
PESUDOVS, K., BURR, J. M., HARLEY, C., & ELLIOTT, D. B. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e318141fe75 · Cited by 403 · cited 1×
“8 is the minimum level of discrimination for an instrument to be considered satisfactory.(24)”
BackgroundSelf-citationThe association of multiple visual impairments with self-reported visual disability: SEE project.
Rubin, G. S., Bandeen‐Roche, K., Huang, G., Muñoz, B. E., Schein, O. D., Fried, L. P., & West, S. K. (2001) · PubMed · Cited by 337
Report from the NEI/FDA Ophthalmic Clinical Trial Design and Endpoints Symposium *
Csaky, K. G., Richman, E. A., & Ferris, F. L. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1132 · Cited by 265
Psychometric properties of vision‐related quality of life questionnaires: a systematic review
De Boer, M. R., Moll, A. C., De Vet, H. C. W., Terwee, C. B., Völker‐Dieben, H. J. M., & Van Rens, G. H. M. B. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00187.x · Cited by 263 · cited 1×
“According to traditional criteria, the NEI VFQ is ranked among the better patient-reported outcomes instruments with good construct validity.(11) An essential characteristic of a valid questionnaire is unidimensionality, meaning that all questions included in a single score contribute to the measurement of a single co…”
MethodLundström, M., & Pesudovs, K. (2009) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2008.11.038 · Cited by 252
Self-citationVisual Function Assessment Questionnaires
Massof, R. W., & Rubin, G. S. (2001) · Survey of Ophthalmology · doi:10.1016/s0039-6257(01)00194-1 · Cited by 247 · cited 1×
“This approach has been described.(36,45) Rasch analysis locates item difficulty and person ability on a logit scale.”
MethodThe Quality of Life Impact of Refractive Correction (QIRC) Questionnaire: Development and Validation
Pesudovs, K., Garamendi, E., & Elliott, D. B. (2004) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2004.tb01962.x · Cited by 242
Self-citationLamoureux, E. L., Pallant, J. F., Pesudovs, K., Hassell, J. B., & Keeffe, J. E. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0220 · Cited by 227
Self-citationThe Measurement of Vision Disability
Massof, R. W. (2002) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2002.tb01524.x · Cited by 201
Evaluation of Quality of Life for Patients With Glaucoma
Spaeth, G., Walt, J., & Keener, J. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.07.075 · Cited by 185
Pesudovs, K., Garamendi, E., Keeves, J. P., & Elliott, D. B. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1075 · Cited by 183
Self-citationCosta, E., Dewey, M. E., Stewart, R. J., Banerjee, S., Huppert, F. A., de Mendonça-Lima, C. A., Büla, C., Reisches, F., Wancata, J., Ritchie, K. A., et al. (2008) · International Journal of Methods in Psychiatric Research · doi:10.1002/mpr.236 · Cited by 182 · cited 1×
“However, the multidimensionality of the NEI VFQ is an inherent feature of the instrument that would be consistently demonstrable across populations.(62) Thus, identification of the flaws in the original instrument and the revisions we propose represent important progress for the use of the NEI VFQ.”
MethodMassof, R. W., & Fletcher, D. C. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00249-2 · Cited by 176 · cited 1×
“This approach has been described.(36,45) Rasch analysis locates item difficulty and person ability on a logit scale.”
MethodWright, B. D., & Mok, M. M. C. (2000) · PubMed · Cited by 172
Bach, J. R., & Tilton, M. C. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90183-x · Cited by 170 · cited 1×
“Although there is overlap between these 2 concepts, evidence suggests they are not interchangeable.(14) Recent studies indicate that the NEI VFQ does not measure quality of life but does measure visual functioning.”
BackgroundCone- and Rod-Mediated Dark Adaptation Impairment in Age-Related Maculopathy
Owsley, C., McGwin, G., Jackson, G. R., Kallies, K., & Clark, M. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.12.023 · Cited by 168
Sharma, S. (2001) · Ophthalmology · doi:10.1016/s0161-6420(01)00764-3 · Cited by 146
Vision-related quality of life in patients with diabetic macular oedema
Hariprasad, S. M., Mieler, W. F., Grassi, M., Green, J. L., Jager, R. D., & Miller, L. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.122416 · Cited by 136 · cited 1×
“Although our NEI VFQ summary scores are comparable to those in other cataract surgery populations,(2) lower scores have been reported for eye diseases, such as diabetic macular edema (approximately 9 points lower) and age-related macular degeneration (approximately 2 points lower).(57,58) This does not mean that our r…”
ResultMeasurement of Ocular Surface Irritation on a Linear Interval Scale with the Ocular Comfort Index
Johnson, M. E., & Murphy, P. J. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1253 · Cited by 136 · cited 1×
“Although this could improve targeting, a better approach is to use Rasch analysis in the initial development of the instrument; there are many such examples in ophthalmology.(27,28,64,65) However, a better strategy would be to develop an item bank and computer-adaptive testing.”
MethodWang, W., Yao, G., Tsai, Y., Wang, J., & Hsieh, C. (2006) · Quality of Life Research · doi:10.1007/s11136-005-4365-7 · Cited by 129
Garamendi, E., Pesudovs, K., Stevens, M. J., & Elliott, D. B. (2005) · Vision Research · doi:10.1016/j.visres.2005.07.007 · Cited by 121
Self-citationRevicki, D. A., Rentz, A. M., Harnam, N., Thomas, V. S., & Lanzetta, P. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3766 · Cited by 115 · cited 2×
“Although our NEI VFQ summary scores are comparable to those in other cataract surgery populations,(2) lower scores have been reported for eye diseases, such as diabetic macular edema (approximately 9 points lower) and age-related macular degeneration (approximately 2 points lower).(57,58) This does not mean that our r…”
BackgroundResultPatient-centred measurement in ophthalmology – a paradigm shift
Pesudovs, K. (2006) · BMC Ophthalmology · doi:10.1186/1471-2415-6-25 · Cited by 111
Self-citationWhy Measurement Matters for Measuring Patient Vision Outcomes
Mallinson, T. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181339f44 · Cited by 108 · cited 1×
“An essential characteristic of a valid questionnaire is unidimensionality, meaning that all questions included in a single score contribute to the measurement of a single construct.(12) If unidimensionality is violated, it is not appropriate to report a single overall score derived from all questionsdtypically the mai…”
BackgroundPsychometric properties of the Greek version of the NEI-VFQ 25
Labiris, G., Katsanos, A., Fanariotis, M., Tsirouki, T., Pefkianaki, M., Chatzoulis, D., & Tsironi, E. E. (2008) · BMC Ophthalmology · doi:10.1186/1471-2415-8-4 · Cited by 97
The Contact Lens Impact on Quality of Life (CLIQ) Questionnaire: Development and Validation
Pesudovs, K., Garamendi, E., & Elliott, D. B. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0933 · Cited by 83 · cited 1×
“Although this could improve targeting, a better approach is to use Rasch analysis in the initial development of the instrument; there are many such examples in ophthalmology.(27,28,64,65) However, a better strategy would be to develop an item bank and computer-adaptive testing.”
MethodSelf-citationAn instrument for assessment of subjective visual disability in cataract patients
Pesudovs, K., & Coster, D. J. (1998) · British Journal of Ophthalmology · doi:10.1136/bjo.82.6.617 · Cited by 76
Self-citationLamoureux, E. L., Pesudovs, K., Pallant, J., Rees, G., Hassell, J. B., Caudle, L. E., & Keeffe, J. E. (2008) · Ophthalmic Epidemiology · doi:10.1080/09286580802256559 · Cited by 66 · cited 1×
“Although this may be true in some cases, item calibrations can vary across populations, albeit with much less error than simple application of ordinal values.(33) Targeting, and to a lesser extent DIF, are also likely to vary with populations.”
BackgroundSelf-citationEspindle, D. M., Crawford, B., Maxwell, A., Rajagopalan, K., Barnes, R., Harris, B., & Hileman, K. S. (2005) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2005.03.060 · Cited by 65
Using the VA LV VFQ‐48 and LV VFQ‐20 in Low Vision Rehabilitation
Stelmack, J. A., & Massof, R. W. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181339f1a · Cited by 64 · cited 1×
“Although this could improve targeting, a better approach is to use Rasch analysis in the initial development of the instrument; there are many such examples in ophthalmology.(27,28,64,65) However, a better strategy would be to develop an item bank and computer-adaptive testing.”
MethodLamoureux, E. L., Hooper, C., Lim, L. L., Pallant, J., Hunt, N. C., Keeffe, J. E., & Guymer, R. H. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e31812f755f · Cited by 64
Self-citationLikert and Guttman scaling of visual function rating scale questionnaires
Massof, R. W. (2004) · Ophthalmic Epidemiology · doi:10.1080/09286580490888771 · Cited by 63
Turano, K. A., Massof, R. W., & Quigley, H. A. (2002) · PubMed · Cited by 62
An Interval‐Scaled Scoring Algorithm for Visual Function Questionnaires
Massof, R. W. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e31812f5f35 · Cited by 62
Application of Stochastic Measurement Models to Visual Function Rating Scale Questionnaires
Massof, R. W. (2005) · Ophthalmic Epidemiology · doi:10.1080/09286580590932789 · Cited by 56
Bühren, J., Pesudovs, K., Martin, T., Strenger, A., Yoon, G., & Kohnen, T. (2009) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2008.12.039 · Cited by 54
Self-citationWang, C., Chan, C., & Jin, H.-Y. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e31818b9f23 · Cited by 53 · cited 1×
“Other studies evaluating NEI VFQ translations in a Rasch model did not fully evaluate its overall and subscale validity, including unidimensionality.(38,39) Assessment of the performance of an entire instrument does not confer validity to its subscales.”
BackgroundAre Standard Instruments Valid for the Assessment of Quality of Life and Symptoms in Glaucoma?
Lamoureux, E. L., Ferraro, J. G., Pallant, J., Pesudovs, K., Rees, G., & Keeffe, J. E. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181334b83 · Cited by 44
Self-citationGothwal, V. K., Wright, T. A., Lamoureux, E. L., & Pesudovs, K. (2009) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2009.03.056 · Cited by 42
Self-citationRyan, B., Court, H., & Margrain, T. H. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e31816225dc · Cited by 40 · cited 9×
“However, the multidimensionality of the NEI VFQ is an inherent feature of the instrument that would be consistently demonstrable across populations.62 Thus, identification of the flaws in the original instrument and the revisions we propose represent important progress for the use of the NEI VFQ.”
BackgroundMethodInfluentialvan Nispen, R. M. A., Knol, D. L., Neve, H. J., & van Rens, G. H. M. B. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.012 · Cited by 39 · cited 1×
“In particular, multilevel models allow simultaneous analysis of different dimensions in a multidimensional instrument.(63) However, segregation of the constructs and individual Rasch analyses is fundamentally a stepwise version of the same procedure.”
BackgroundThe efficacy of a nurse‐led preoperative cataract assessment and postoperative care clinic
Kirkwood, B. J., Pesudovs, K., Latimer, P., & Coster, D. J. (2006) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2006.tb00237.x · Cited by 37
Self-citationImprovements in vision-related quality of life with AcrySof IQ SN60WF aspherical intraocular lenses
Lin, I., Wang, I., Lei, M.-S., Lin, L. L., & Hu, F. (2008) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2008.04.028 · Cited by 36
What do Different Visual Function Questionnaires Measure?
Massof, R. W., & Ahmadian, L. (2007) · Ophthalmic Epidemiology · doi:10.1080/09286580701487883 · Cited by 33
Correlation between vision‐ and health‐related quality of life scores
Swamy, B. N., Chia, E., Wang, J. J., Rochtchina, E., & Mitchell, P. (2008) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01203.x · Cited by 31 · cited 1×
“Perhaps this is why the total score on the NEI VFQ-25 correlates poorly with a global rating of quality of life or health-related quality of life.(15,56,57) One can measure both socioemotional issues and visual functioning with the NEI VFQ; by reporting scores from the 2 dimensions, one can claim that vision-related q…”
BackgroundThe efficacy of a nurse‐led preoperative cataract assessment and postoperative care clinic
McKee, H. D. R., & Gole, G. A. (2006) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2006.tb00453.x · Cited by 30 · cited 5×
“The patients were representative of the elderly cataract population in Australia.42 Routine clinical assessments were performed.”
BackgroundResultInfluentialGrow, S. J. L. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e31812f5f24 · Cited by 8 · cited 1×
“Perhaps this is why the total score on the NEI VFQ-25 correlates poorly with a global rating of quality of life or health-related quality of life.(15,56,57) One can measure both socioemotional issues and visual functioning with the NEI VFQ; by reporting scores from the 2 dimensions, one can claim that vision-related q…”
BackgroundInteractive, computer-based, self-reported, visual function questionnaire: the PalmPilot-VFQ
Ünver, Y. B., Yavuz, G. A., & Sinclair, S. H. (2009) · Eye · doi:10.1038/eye.2009.101 · Cited by 7
Cited by
Social and emotional impact of diabetic retinopathy: a review
Fenwick, E., Rees, G., Pesudovs, K., Dirani, M., Kawasaki, R., Wong, T. Y., & Lamoureux, E. (2012) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2011.02599.x · Cited by 156
Self-citation
Metadata
- Authors
- Pesudovs, K., Gothwal, V. K., Wright, T., & Lamoureux, E. L.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2010-05
- Volume
- 36
- Issue
- 5
- Pages
- 718-732
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2123007530
- Cited by
- 212
- References
- 60
- FWCI
- 20.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.