CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: This review compared Computer-aided designand Computer-aided manufactured (CAD-CAM) and conventionally constructed removable complete dentures (CDs). DATA: Seventy-three studies reporting on CAD-CAM (milled/3D-printed) CDs were included in this review. The most recent literature search was performed on 15/03/2021. SOURCES: Two investigators searched electronic databases [PubMed (MEDLINE), Embase, CENTRAL], online search engines (Google) and research portals. Hand searches were performed to identify literature not available online. STUDY SELECTION: Studies on CAD-CAM CDs were included if they reported on trueness of fit, biocompatibility, mechanical, surface, chemical, color , microbiological properties, time-cost analysis, and clinical outcomes. Inter-investigator reliability was assessed using kappa scores. Meta-analyses were performed on the extracted data . RESULTS: The kappa score ranged between 0.897-1.000. Meta-analyses revealed that 3D-printed CDs were more true than conventional CDs (p = 0.039). Milled CDs had a higher flexural-strength than conventional and 3D-printed CDs (p < 0.0001). Milled CDs had a higher flexural-modulus than 3D-printed CDs (p < 0.0001). Milled CDs had a higher yield-strength than injection-molded (p = 0.004), and 3D-printed CDs (p = 0.001). Milled CDs had superior toughness (p < 0.0001) and surface roughness characteristics (p < 0.0001) than other CDs . Rapidly-prototyped CDs displayed poor color-stability compared to other CDs (p = 0.029). CAD-CAM CDs d displayed better retention than conventional CDs (p = 0.015). Conventional CDs had a higher strain at yield point than milled CDs (p < 0.0001), and had superior esthetics than 3D-printed (p < 0.0001). Fabrication of CAD-CAM CDs required less chairside time (p = 0.037) and lower overall costs (p < 0.0001) than conventional CDs. CONCLUSIONS: This systematic review concludes that CAD-CAM CDs offer a number of improved mechanical/surface properties and are not inferior when compared to conventional CDs. CLINICAL SIGNIFICANCE: CAD-CAM CDs should be considered for completely edentulous patients whenever possible, since this technique offers numerous advantages including better retention, mechanical and surface properties but most importantly preserves a digital record. This can be a great advantage for older adults with limited access to dental care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 1×
“Random-effects or fixed-effects models were used to calculate the weighted means across the studies [12] and I-squared statistics (I2-statistics) was used to assess the heterogeneity Table 9 (continued )”
MethodA review of assessing the accuracy of classifications of remotely sensed data
Congalton, R. G. (1991) · Remote Sensing of Environment · doi:10.1016/0034-4257(91)90048-b · Cited by 7,724 · cited 1×
“The clinical retention of a CD depends, apart from the morphology and resilience of the denture bearing tissues, on adaptation of the intaglio surface to the tissues, border seal, and salivary flow-related effects associated with viscosity and film thickness of the oral fluid [86,87].”
BackgroundFunnel plots for detecting bias in meta-analysis
Sterne, J. A. C., & Egger, M. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00377-8 · Cited by 3,779 · cited 1×
“Risk of publication bias was assessed across the studies using funnel plots [13].”
MethodThe future of dental devices is digital
van Noort, R. (2012) · Dental Materials · doi:10.1016/j.dental.2011.10.014 · Cited by 1,408
Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques
Goodacre, B. J., Goodacre, C. J., Baba, N. Z., & Kattadiyil, M. T. (2016) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.02.017 · Cited by 331 · cited 2×
“(2016) [49] Compression molding Lucitone 199 Denture Base Resin, Dentsply Sirona 0.”
BackgroundKattadiyil, M. T., Jekki, R., Goodacre, C. J., & Baba, N. Z. (2015) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.08.001 · Cited by 272 · cited 2×
“(2015) [23] Compressionmolding Lucitone 199, Dentsply Intl NS N/A 15 Predoctoral dental students delivered two sets of dentures, compression molding and milled dentures, for each patient.”
MethodKalberer, N., Mehl, A., Schimmel, M., Müller, F., & Srinivasan, M. (2019) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2018.09.001 · Cited by 265 · cited 1×
“(2019) [39] Milled AvaDent Digital Dental Solutions 0.”
BackgroundSelf-citationRelationship of nutritional status and oral health in elderly: Systematic review with meta-analysis
Toniazzo, M. P., Amorim, P. D. S., Muniz, F. W. M. G., & Weidlich, P. (2018) · Clinical Nutrition · doi:10.1016/j.clnu.2017.03.014 · Cited by 222
Developing Short‐form Measures of Oral Health‐related Quality of Life
Locker, D., & Allen, P. F. (2002) · Journal of Public Health Dentistry · doi:10.1111/j.1752-7325.2002.tb03415.x · Cited by 197 · cited 1×
“This review did not identify any clinical studies which utilized Quality of Life measures, despite a number of instruments specifically developed for edentate older adults [105].”
BackgroundSchimmel, M., Srinivasan, M., McKenna, G., & Müller, F. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13288 · Cited by 195 · cited 1×
“The protocol used in this systematic review is similar to the design used in previously published systematic reviews [10,11].”
MethodSelf-citationDental implants in the elderly population: a systematic review and meta‐analysis
Srinivasan, M., Meyer, S., Mombelli, A., & Müller, F. (2017) · Clinical Oral Implants Research · doi:10.1111/clr.12898 · Cited by 178 · cited 1×
“The protocol used in this systematic review is similar to the design used in previously published systematic reviews [10,11].”
MethodSelf-citationPrognostic indicators for conventional complete denture therapy: A review of the literature
Critchlow, S. B., & Ellis, J. S. (2009) · Journal of Dentistry · doi:10.1016/j.jdent.2009.08.004 · Cited by 176 · cited 1×
“Given that successful CD therapy is often built on a positive relationship between patient and clinician, incorporating the patient’s opinions into the final prostheses, is very important [104].”
BackgroundHada, T., Kanazawa, M., Iwaki, M., Arakida, T., Soeda, Y., Katheng, A., Otake, R., & Minakuchi, S. (2020) · Materials · doi:10.3390/ma13153405 · Cited by 169 · cited 1×
“(2020) [29] 3D-printing Orientation: 0o Clear, Formlabs 0.”
Oral Hygiene Reduces the Mortality from Aspiration Pneumonia in Frail Elders
Müller, F. (2014) · Journal of Dental Research · doi:10.1177/0022034514552494 · Cited by 158 · cited 1×
“Microbial contamination of denture surfaces can elicit localized intra-oral mucosal infections but have also been implicated in the aetiology of aspiration pneumonia in dependent older adults [97].”
BackgroundSelf-citationAlfouzan, A. F., Almejrad, L., & Albarrag, A. (2017) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2017.9.5.402 · Cited by 157
CAD/CAM milled removable complete dentures: time and cost estimation study
Srinivasan, M., Schimmel, M., Naharro, M., Neill, C. O., McKenna, G. J., & Müller, F. (2018) · Journal of Dentistry · doi:10.1016/j.jdent.2018.09.003 · Cited by 141
Self-citationIncome inequality, social capital and self-rated health and dental status in older Japanese
Aida, J., Kondo, K., Kondo, N., Watt, R. G., Sheiham, A., & Tsakos, G. (2011) · Social Science & Medicine · doi:10.1016/j.socscimed.2011.09.005 · Cited by 140
In Vitro Evaluation of Adhesion of Candida albicans on CAD/CAM PMMA‐Based Polymers
Murat, S., Çakmak, G., Alatalı, C., & Uzun, M. (2018) · Journal of Prosthodontics · doi:10.1111/jopr.12942 · Cited by 134 · cited 2×
“(2019) [73] Compressionmolding Promolux, Merz Dental GmbH 279.”
BackgroundFlexural and fatigue strengths of denture base resin
Diaz-Arnold, A. M., Vargas, M. A., Shaull, K. L., Laffoon, J. E., & Qian, F. (2008) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)60136-5 · Cited by 134 · cited 1×
“High flexural strength is imperative for sustained successful CD wear as alveolar resorption is a continual and irregular process which can lead to uneven prosthesis support [96].”
BackgroundBidra, A. S., Farrell, K. A., Burnham, D. B., Dhingra, A., Taylor, T. D., & Kuo, C. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.10.023 · Cited by 127 · cited 3×
“(2016) [19] Milled Avadent, Global Dental Science NS VAS scores, higher scores mean more favorable perception by patients N/A 20 The old dentures were replaced with milling complete dentures.”
BackgroundMethodCAD/CAM Complete Denture Resins: An In Vitro Evaluation of Color Stability
Gruber, S., Kamnoedboon, P., Özcan, M., & Srinivasan, M. (2020) · Journal of Prosthodontics · doi:10.1111/jopr.13246 · Cited by 123 · cited 1×
“(2020) [79] Compression-molding PS ProBase Hot, Ivoclar Vivadent AG 0.”
Self-citationQuality assessment tools used in systematic reviews of in vitro studies: A systematic review
Tran, L., Tam, D. N. H., Elshafay, A., Dang, T., Hirayama, K., & Huy, N. T. (2021) · BMC Medical Research Methodology · doi:10.1186/s12874-021-01295-w · Cited by 118 · cited 1×
“The majority of the studies included in this review were in vitro studies; currently, a universal methodological assessment tool for in vitro studies that assesses all critical aspects of in vitro metanalysis does not exist [106], hence quality assessment of these in vitro studies could not be performed.”
BackgroundCAD/CAM milled removable complete dentures: an in vitro evaluation of trueness
Srinivasan, M., Cantin, Y., Mehl, A. C., Gjengedal, H., Müller, F., & Schimmel, M. (2016) · Clinical Oral Investigations · doi:10.1007/s00784-016-1989-7 · Cited by 114 · cited 1×
“(2017) [48] Compression-molding Ivoclar ProBase, Ivoclar Vivadent AG 0.”
MethodSelf-citationYoon, H., Hwang, H.-J., Ohkubo, C., Han, J., & Park, E. (2018) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2018.01.027 · Cited by 104 · cited 1×
“(2018) [46] Compression-molding SR Triplex Hot,”
Katheng, A., Kanazawa, M., Iwaki, M., & Minakuchi, S. (2020) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2020.02.023 · Cited by 97 · cited 1×
“(2020) [32] 3D-printing Polymerization time: 15 min, Temperature: 40 ◦C Clear resin, Formlabs NS 10 Samples: Geometric specimen that simulated maxillary complete denture with different polymerization time and”
Li, P., Fernandez, P. K., Klink, A., Xu, Y., & Spintzyk, S. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104227 · Cited by 94 · cited 1×
“(2021) [56] 3D-printing FREEPRINT denture, Detax NS Shear bond strength between repair resin and testing material 20 3D-printed denture base material was treated with different surface treatments (no surface treatment, monomer applying, carbide paper”
MethodWatson, S., McGowan, L. J., McCrum, L.-A., Cardwell, C. R., McGuinness, B., Moore, C., Woodside, J. V., & McKenna, G. J. (2019) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-019-0803-8 · Cited by 82
Self-citationYoon, S., Oh, K. C., Lee, S. J., Han, J., & Yoon, H. (2020) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2019.11.007 · Cited by 72 · cited 2×
“An additional 5 articles [16,31,34,63,82] Table 10 Studies reporting surface wettability of denture bases.”
BackgroundChen, H., Wang, H., Lv, P., Wang, Y., & Sun, Y. (2015) · BioMed Research International · doi:10.1155/2015/453968 · Cited by 60 · cited 1×
“(2015) [51] Conventional method (Wax) NS 0.”
Gao, H., Yang, Z., Lin, W., Tan, J., & Chen, L. (2021) · Journal of Prosthodontics · doi:10.1111/jopr.13330 · Cited by 60 · cited 1×
“(2021) [25] 3D-printing Orientation: 0o VisJet M3 crystal, 3D systems 0.”
Deng, K., Chen, H., Zhao, Y., Zhou, Y., Wang, Y., & Sun, Y. (2018) · PLOS ONE · doi:10.1371/journal.pone.0201777 · Cited by 52 · cited 1×
“(2018) [43] 3D-printing (Polylactic acid) FDM 3D printer, Lingtong-II 0.”
Changes caused by processing complete mandibular dentures
Lechner, S. K., & Thomas, G. A. (1994) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(94)90293-3 · Cited by 32 · cited 1×
“However, polymerization shrinkage of conventional CD bases can negatively impact on adaptation and retention [93].”
BackgroundManaging Edentate Older Adults
Srinivasan, M., Schimmel, M., Leles, C. R., & McKenna, G. J. (2020) · Primary Dental Journal · doi:10.1177/2050168420943410 · Cited by 7
Self-citation
Metadata
- Authors
- Srinivasan, M., Kamnoedboon, P., McKenna, G., Angst, L., Schimmel, M., Özcan, M., & Müller, F.
- Venue
- Journal of Dentistry
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 113
- Pages
- 103777
- ISSN
- 0300-5712 (ISSN-L)
- OpenAlex
- W3194106948
- Cited by
- 205
- References
- 36
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.