CoChat

A deep neural network learning algorithm outperforms a conventional algorithm for emergency department electrocardiogram interpretation

Smith, Stephen W., Walsh, Brooks, Grauer, Ken, Wang, Kyuhyun, Rapin, Jeremy, Li, Jia, Fennell, William, Taboulet, Pierre · 2019 · Journal of Electrocardiology
Cited by 106

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND Cardiologs® has developed the first electrocardiogram (ECG) algorithm that uses a deep neural network (DNN) for full 12‑lead ECG analysis, including rhythm, QRS and ST-T-U waves. We compared the accuracy of the first version of Cardiologs® DNN algorithm to the Mortara/Veritas® conventional algorithm in emergency department (ED) ECGs. METHODS Individual ECG diagnoses were prospectively mapped to one of 16 pre-specified groups of ECG diagnoses, which were further classified as "major" ECG abnormality or not. Automated interpretations were compared to blinded experts'. The primary outcome was the performance of the algorithms in finding at least one "major" abnormality. The secondary outcome was the proportion of all ECGs for which all groups were identified, with no false negative or false positive groups ("accurate ECG interpretation"). Additionally, we measured sensitivity and positive predictive value (PPV) for any abnormal group. RESULTS Cardiologs® vs. Veritas® accuracy for finding a major abnormality was 92.2% vs. 87.2% (p < 0.0001), with comparable sensitivity (88.7% vs. 92.0%, p = 0.086), improved specificity (94.0% vs. 84.7%, p < 0.0001) and improved positive predictive value (PPV 88.2% vs. 75.4%, p < 0.0001). Cardiologs® had accurate ECG interpretation for 72.0% (95% CI: 69.6-74.2) of ECGs vs. 59.8% (57.3-62.3) for Veritas® (P < 0.0001). Sensitivity for any abnormal group for Cardiologs® and Veritas®, respectively, was 69.6% (95CI 66.7-72.3) vs. 68.3% (95CI 65.3-71.1) (NS). Positive Predictive Value was 74.0% (71.1-76.7) for Cardiologs® vs. 56.5% (53.7-59.3) for Veritas® (P < 0.0001). CONCLUSION Cardiologs' DNN was more accurate and specific in identifying ECGs with at least one major abnormal group. It had a significantly higher rate of accurate ECG interpretation, with similar sensitivity and higher PPV.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jelectrocard.2018.11.013

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Smith, S. W., Walsh, B., Grauer, K., Wang, K., Rapin, J., Li, J., Fennell, W., & Taboulet, P.
Venue
Journal of Electrocardiology
Publisher
Elsevier BV
Published
2019-01
Volume
52
Pages
88-95
ISSN
0022-0736 (ISSN-L)
OpenAlex
W2900614987
Cited by
106
References
1
FWCI
7.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.