CoChat

Tele-electrocardiography and bigdata: The CODE (Clinical Outcomes in Digital Electrocardiography) study

Open access
Ribeiro, Antonio Luiz P., Paixão, Gabriela M.M., Gomes, Paulo R., Ribeiro, Manoel Horta, Ribeiro, Antônio H., Canazart, Jéssica A., Oliveira, Derick M., Ferreira, Milton P., Lima, Emilly M., Moraes, Jermana Lopes de, Castro, Nathalia, Ribeiro, Leonardo B., Macfarlane, Peter W. · 2019 · Journal of Electrocardiology
Cited by 84

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Digital electrocardiographs are now widely available and a large number of digital electrocardiograms (ECGs) have been recorded and stored. The present study describes the development and clinical applications of a large database of such digital ECGs, namely the CODE (Clinical Outcomes in Digital Electrocardiology) study. ECGs obtained by the Telehealth Network of Minas Gerais, Brazil, from 2010 to 17, were organized in a structured database. A hierarchical free-text machine learning algorithm recognized specific ECG diagnoses from cardiologist reports. The Glasgow ECG Analysis Program provided Minnesota Codes and automatic diagnostic statements. The presence of a specific ECG abnormality was considered when both automatic and medical diagnosis were concordant; cases of discordance were decided using heuristisc rules and manual review. The ECG database was linked to the national mortality information system using probabilistic linkage methods. From 2,470,424 ECGs, 1,773,689 patients were identified. After excluding the ECGs with technical problems and patients <16 years-old, 1,558,415 patients were studied. High performance measures were obtained using an end-to-end deep neural network trained to detect 6 types of ECG abnormalities, with F1 scores >80% and specificity >99% in an independent test dataset. We also evaluated the risk of mortality associated with the presence of atrial fibrillation (AF), which showed that AF was a strong predictor of cardiovascular mortality and mortality for all causes, with increased risk in women. In conclusion, a large database that comprises all ECGs performed by a large telehealth network can be useful for further developments in the field of digital electrocardiography, clinical cardiology and cardiovascular epidemiology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jelectrocard.2019.09.008

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 84

Metadata

Authors
Ribeiro, A. L. P., Paixão, G. M. M., Gomes, P. R., Ribeiro, M. H., Ribeiro, A. H., Canazart, J. A., Oliveira, D. M., Ferreira, M. P., Lima, E. M., Moraes, J. L. D., Castro, N., Ribeiro, L. B., & Macfarlane, P. W.
Venue
Journal of Electrocardiology
Publisher
Elsevier BV
Published
2019-11
Volume
57
Pages
S75-S78
ISSN
0022-0736 (ISSN-L)
OpenAlex
W2971393043
Cited by
84
References
7
FWCI
4.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tele-electrocardiography and bigdata: The CODE (Clinical Outcomes in Digital Electrocardiography) study. https://app.cochat.ai/papers/10.1016/j.jelectrocard.2019.09.008
The paper
Ribeiro, A. L. P., Paixão, G. M. M., Gomes, P. R., Ribeiro, M. H., Ribeiro, A. H., Canazart, J. A., Oliveira, D. M., Ferreira, M. P., Lima, E. M., Moraes, J. L. D., Castro, N., Ribeiro, L. B., & Macfarlane, P. W. (2019). Tele-electrocardiography and bigdata: The CODE (Clinical Outcomes in Digital Electrocardiography) study. Journal of Electrocardiology. https://doi.org/10.1016/j.jelectrocard.2019.09.008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.