Can muscle coordination be precisely studied by surface electromyography?
The DOI matches its Crossref record; 109 of the 109 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,645
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Five basic muscle activation patterns account for muscle activity during human locomotion
Ivanenko, Y. P., Poppele, R. E., & Lacquaniti, F. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.057174 · Cited by 1,072
Hodges, P. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95190-5 · Cited by 983
Model-based estimation of muscle forces exerted during movements
Erdemir, A., McLean, S., Herzog, W., & van den Bogert, A. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.005 · Cited by 872
Cited by
Surface EMG in Clinical Assessment and Neurorehabilitation: Barriers Limiting Its Use
Campanini, I., Disselhorst-Klug, C., Rymer, W. Z., & Merletti, R. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00934 · Cited by 270
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“However, due to complexities associated with sEMG recording [59, 60], wide inter- and intra-user variability in detectable muscle synergies [25, 61], and general nonlinear properties of sEMG signals [62], most proposed control schemes have struggled to provide robust and reliable systems.”
BackgroundInfluentialConsistency of muscle synergies during pedaling across different mechanical constraints
Hug, F., Turpin, N. A., Couturier, A., & Dorel, S. (2011) · Journal of Neurophysiology · doi:10.1152/jn.01096.2010 · Cited by 204
“Since the low-pass cutoff frequency influences the smoothing of EMG patterns and thus could influence the number of extracted muscle synergies (Hug 2011), the low-pass cutoff frequency was adapted to the pedaling rate to obtain the same pattern smoothing across conditions (5 Hz for 60% of fopt, 7 Hz for 80% of fopt, 9…”
MethodInfluentialSelf-citationElectromyographic activity in deadlift exercise and its variants. A systematic review
Martín-Fuentes, I., Oliva-Lozano, J. M., & Muyor, J. M. (2020) · PLOS ONE · doi:10.1371/journal.pone.0229507 · Cited by 70
“For instances, athletes have the possibility to perform a concrete exercise when targeting a particular muscle [18, 19].”
BackgroundEffect of power output on muscle coordination during rowing
Turpin, N. A., Guével, A., Durand, S., & Hug, F. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1928-x · Cited by 66
Self-citationAvila, E. R., Williams, S. E., & Disselhorst-Klug, C. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111687 · Cited by 44
A comparison of electromyography and stroke kinematics during ergometer and on-water rowing
Fleming, N., Donne, B., & Mahony, N. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.886128 · Cited by 43
“The failure to normalise these discrete phases of the stroke cycle may have induced artificial differences in EMG data which are a result of timing differences in the stroke cycle (Hug, 2011).”
BackgroundInvestigation of physiological properties of nerves and muscles using electromyography
Roe, S. M., Johnson, C. D., & Tansey, E. A. (2014) · Advances in Physiology Education · doi:10.1152/advan.00018.2014 · Cited by 8
“Examples of this use are in biomechanics and gait analysis (7, 10, 16) and in sleep studies (15, 18), where the magnitude of muscle activation and latencies are important.”
Background
Metadata
- Authors
- Hug, F.
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 2011-02
- Volume
- 21
- Issue
- 1
- Pages
- 1-12
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W2077507903
- Cited by
- 352
- References
- 109
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.