The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
The role of muscle synergies in myoelectric control: trends and challenges for simultaneous multifunction control
Open accessAbstract
Myoelectric control is filled with potential to significantly change human-robot interaction due to the ability to non-invasively measure human motion intent. However, current control schemes have struggled to achieve the robust performance that is necessary for use in commercial applications. As demands in myoelectric control trend toward simultaneous multifunctional control, multi-muscle coordinations, or synergies, play larger roles in the success of the control scheme. Detecting and refining patterns in muscle activations robust to the high variance and transient changes associated with surface electromyography is essential for efficient, user-friendly control. This article reviews the role of muscle synergies in myoelectric control schemes by dissecting each component of the scheme with respect to associated challenges for achieving robust simultaneous control of myoelectric interfaces. Electromyography recording details, signal feature extraction, pattern recognition and motor learning based control schemes are considered, and future directions are proposed as steps toward fulfilling the potential of myoelectric control in clinically and commercially viable applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The pascal visual object classes (VOC) challenge
Everingham, M., Van Gool, L., Williams, C. K. I., Winn, J., & Zisserman, A. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-009-0275-4 · Cited by 19,599
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
Willigenburg, N. W., Daffertshofer, A., Kingma, I., & van Dieën, J. H. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.01.001 · Cited by 120
Cited by
Santello, M., Bianchi, M., Gabiccini, M., Ricciardi, E., Salvietti, G., Prattichizzo, D., Ernst, M., Moscatelli, A., Jörntell, H., Kappers, A. M. L., et al. (2016) · Physics of Life Reviews · doi:10.1016/j.plrev.2016.02.001 · Cited by 307
Motion capture sensing techniques used in human upper limb motion: a review
Yahya, M., Shah, J. A., Kadir, K. A., Yusof, Z. M., Khan, S., & Warsi, A. (2019) · Sensor Review · doi:10.1108/sr-10-2018-0270 · Cited by 82
Fascicular topography of the human median nerve for neuroprosthetic surgery
Delgado-Martínez, I., Badia, J., Pascual-Font, A., Rodríguez-Baeza, A., & Navarro, X. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00286 · Cited by 77
Fani, S., Bianchi, M., Jain, S., Pimenta Neto, J. S., Boege, S., Grioli, G., Bicchi, A., & Santello, M. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00011 · Cited by 31
Metadata
- Authors
- Ison, M., & Artemiadis, P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-09-04
- Volume
- 11
- Issue
- 5
- Pages
- 051001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1984002649
- Cited by
- 225
- References
- 13
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The role of muscle synergies in myoelectric control: trends and challenges for simultaneous multifunction control. https://app.cochat.ai/papers/10.1088/1741-2560/11/5/051001
- The paper
- Ison, M., & Artemiadis, P. (2014). The role of muscle synergies in myoelectric control: trends and challenges for simultaneous multifunction control. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/5/051001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.