Supercritical carbon dioxide extraction of hazelnut oil
Open accessThe DOI matches its Crossref record.
Abstract
Abstract Solubility of hazelnut oil in supercritical carbon dioxide (SC-CO2) was determined at 15–60 MPa, and 40–60 °C. The crossover pressure of hazelnut oil was between 15 and 30 MPa. The solubility increased with pressure, but increased with temperature above the crossover pressure. Hazelnut particles (1–2 mm) were extracted at 30–60 MPa, and 40–60 °C with SC-CO2 flow rate of 2 ml/min. Extraction occurred in two periods. The released oil on the surface of particles was extracted in the fast extraction period, and 39% of the initial oil was recovered at each condition. However, the duration of the fast extraction period decreased with increased pressure and temperature. The unreleased oil in the intact cells was extracted in the slow extraction period. The maximum recovery was 59% at 60 MPa and 60 °C, for 180 min of extraction. The fluid phase and solid phase mass transfer coefficients increased with increased pressure and temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Extraction of oil from microalgae for biodiesel production: A review
Halim, R., Danquah, M. K., & Webley, P. A. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.01.001 · Cited by 1,043
Oil extraction from microalgae for biodiesel production
Halim, R., Gladman, B., Danquah, M. K., & Webley, P. A. (2011) · Bioresource Technology · doi:10.1016/j.biortech.2010.06.136 · Cited by 683
“In order to describe the mass transfer behaviour of lipid molecules during SCCO2 extraction, the following kinetic model (Ozkal et al., 2005) was used:”
BackgroundMethodResultApplication of supercritical CO2 in lipid extraction – A review
Sahena, F., Zaidul, I. S. M., Jinap, S., Karim, A. A., Abbas, K. A., Norulaini, N. A. N., & Omar, A. K. M. (2009) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2009.06.026 · Cited by 643
de Melo, M. M. R., Silvestre, A. J. D., & Silva, C. M. (2014) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2014.04.007 · Cited by 520
Chen, Y., Xie, M.-Y., & Gong, X.-F. (2007) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2006.10.018 · Cited by 354
Da Porto, C., Decorti, D., & Tubaro, F. (2012) · Industrial Crops and Products · doi:10.1016/j.indcrop.2011.09.015 · Cited by 236
Supercritical CO2 extraction of omega-3 rich oil from Sacha inchi (Plukenetia volubilis L.) seeds
Follegatti-Romero, L. A., Piantino, C. R., Grimaldi, R., & Cabral, F. A. (2009) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2009.03.010 · Cited by 203
Duba, K. S., & Fiori, L. (2015) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2014.12.021 · Cited by 169
Metadata
- Authors
- Özkal, S. G., Salgın, U., & Yener, M. E.
- Venue
- Journal of Food Engineering
- Publisher
- Elsevier BV
- Published
- 2005-07
- Volume
- 69
- Issue
- 2
- Pages
- 217-223
- ISSN
- 0260-8774 (ISSN-L)
- OpenAlex
- W2046347409
- Cited by
- 134
- References
- 0
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.