Tetracycline degradation by persulfate activated with magnetic Cu/CuFe2O4 composite: Efficiency, stability, mechanism and degradation pathway
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Magnetically separable Cu/CuFe2O4 composite obtained by a solvothermal method was used to active persulfate (PS) for the removal of tetracycline (TC). Under different pH conditions, Cu/CuFe2O4 catalyst exhibited a higher catalytic activity for PS activation to degrade TC than that of CuFe2O4. The effects of some key parameters including initial pH value, PS concentration, catalyst dosage, reaction temperature and coexisting ions on TC degradation were investigated in Cu/CuFe2O4/PS system. The reuse of Cu/CuFe2O4 catalyst at pH 3.50, 7.00 and 11.00 indicated that the catalyst showed a low stability due to the corrosion of metallic copper (Cu°), but bicarbonate ions could enhance the stability and recyclability of this catalyst through the suppression of copper leaching. Both sulfate and hydroxyl radicals were the main reactive species in Cu/CuFe2O4/PS system. Cu° can not only work as electron donor to active PS to produce the reactive radicals but also act as an electron bridge to facilitate the fast electron transfer between PS and catalyst. The structural cuprous and ferrous ions on the surface of CuFe2O4 participated in the PS activation process through the redox reactions, as confirmed by XPS analysis. The possible degradation pathways of TC were proposed based on the identified intermediates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemistry of persulfates in water and wastewater treatment: A review
Wacławek, S., Lutze, H. V., Grübel, K., Padil, V. V. T., Černík, M., & Dionysiou, D. D. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.07.132 · Cited by 1,874
Mechanism of Base Activation of Persulfate
Furman, O. S., Teel, A. L., & Watts, R. J. (2010) · Environmental Science & Technology · doi:10.1021/es1013714 · Cited by 1,396
Zhang, T., Zhu, H., & Croué, J.-P. (2013) · Environmental Science & Technology · doi:10.1021/es304721g · Cited by 1,203
Activation of peroxymonosulfate by base: Implications for the degradation of organic pollutants
Qi, C., Liu, X., Ma, J., Lin, C., Li, X., & Zhang, H. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2016.02.089 · Cited by 1,125
Guan, Y.-H., Ma, J., Ren, Y.-M., Liu, Y.-L., Xiao, J.-Y., Lin, L.-Q., & Zhang, C. (2013) · Water Research · doi:10.1016/j.watres.2013.06.023 · Cited by 1,037
Xie, Z., Feng, Y., Wang, F., Chen, D., Zhang, Q., Zeng, Y., Lv, W., & Liu, G. (2018) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2018.02.011 · Cited by 853
Insights into Heterogeneous Catalysis of Persulfate Activation on Dimensional-Structured Nanocarbons
Duan, X., Sun, H., Kang, J., Wang, Y., Indrawirawan, S., & Wang, S. (2015) · ACS Catalysis · doi:10.1021/acscatal.5b00774 · Cited by 799
Lei, Y., Chen, C.-S., Tu, Y.-J., Huang, Y.-H., & Zhang, H. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b00623 · Cited by 728
Ding, Y., Zhu, L., Wang, N., & Tang, H. (2013) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2012.09.015 · Cited by 693
Xu, Y., Ai, J., & Zhang, H. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.01.023 · Cited by 683
Zhang, X., Ding, Y., Tang, H., Han, X., Zhu, L., & Wang, N. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.09.051 · Cited by 465
Jiang, D., Wang, T., Xu, Q., Li, D., Meng, S., & Chen, M. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.09.001 · Cited by 423
Li, J., Ren, Y., Ji, F., & Lai, B. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.04.104 · Cited by 394
Ding, D., Liu, C., Ji, Y., Yang, Q., Chen, L., Jiang, C., & Cai, T. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.09.077 · Cited by 379
Barhoumi, N., Olvera-Vargas, H., Oturan, N., Huguenot, D., Gadri, A., Ammar, S., Brillas, E., & Oturan, M. A. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.03.034 · Cited by 376
Zhang, X., Feng, M., Qu, R., Liu, H., Wang, L., & Wang, Z. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.04.096 · Cited by 374
Combination of photocatalysis with hydrodynamic cavitation for degradation of tetracycline
Wang, X., Jia, J., & Wang, Y. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.01.011 · Cited by 364
Liu, Y., He, X., Fu, Y., & Dionysiou, D. D. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.11.043 · Cited by 357
Ghauch, A., Baalbaki, A., Amasha, M., El Asmar, R., & Tantawi, O. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.02.133 · Cited by 341
Cao, J., Xiong, Z., & Lai, B. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.03.036 · Cited by 325
Aqueous tetracycline degradation by H2O2 alone: Removal and transformation pathway
Chen, Y.-Y., Ma, Y.-L., Yang, J., Wang, L.-Q., Lv, J.-M., & Ren, C.-J. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.08.046 · Cited by 314
Jawad, A., Lang, J., Liao, Z., Khan, A., Ifthikar, J., Lv, Z., Long, S., Chen, Z., & Chen, Z. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.10.097 · Cited by 288
Jonidi Jafari, A., Kakavandi, B., Jaafarzadeh, N., Rezaei Kalantary, R., Ahmadi, M., & Akbar Babaei, A. (2017) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2016.09.044 · Cited by 285
Shi, W., Guo, F., & Yuan, S. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.03.048 · Cited by 284
Jiang, X., Guo, Y., Zhang, L., Jiang, W., & Xie, R. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.02.034 · Cited by 281
Oxidative degradation of p-chloroaniline by copper oxidate activated persulfate
Liang, H.-Y., Zhang, Y.-Q., Huang, S.-B., & Hussain, I. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.11.093 · Cited by 276
Wang, T., Quan, W., Jiang, D., Chen, L., Li, D., Meng, S., & Chen, M. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.04.128 · Cited by 271
Thermally activated persulfate (TAP) oxidation of antiepileptic drug carbamazepine in water
Deng, J., Shao, Y., Gao, N., Deng, Y., Zhou, S., & Hu, X. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.05.044 · Cited by 268
Tetracycline removal during wastewater treatment in high-rate algal ponds
de Godos, I., Muñoz, R., & Guieysse, B. (2012) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2012.05.106 · Cited by 262
Feng, M., Qu, R., Zhang, X., Sun, P., Sui, Y., Wang, L., & Wang, Z. (2015) · Water Research · doi:10.1016/j.watres.2015.08.011 · Cited by 261
Advanced oxidation processes based on zero-valent aluminium for treating textile wastewater
Khatri, J., Nidheesh, P. V., Anantha Singh, T. S., & Suresh Kumar, M. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.04.074 · Cited by 260
Zhou, P., Zhang, J., Zhang, Y., Zhang, G., Li, W., Wei, C., Liang, J., Liu, Y., & Shu, S. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2017.11.023 · Cited by 256
Lai, B., Zhang, Y., Chen, Z., Yang, P., Zhou, Y., & Wang, J. (2014) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2013.08.020 · Cited by 252
Zhang, Y., Liu, C., Xu, B., Qi, F., & Chu, W. (2016) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.06.003 · Cited by 247
Rate constants for hydrogen abstraction reactions of the sulfate radical, SO4−. Alkanes and ethers
Huie, R. E., & Clifton, C. L. (1989) · International Journal of Chemical Kinetics · doi:10.1002/kin.550210802 · Cited by 160
Sun, H., Yang, X., Zhao, L., Xu, T., & Lian, J. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta02126c · Cited by 152
Xiong, Z., Lai, B., Yang, P., Zhou, Y., Wang, J., & Fang, S. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.05.006 · Cited by 148
Sulfonamides and tetracyclines in livestock wastewater
Kim, H., Hong, Y., Park, J.-E., Sharma, V. K., & Cho, S. (2013) · Chemosphere · doi:10.1016/j.chemosphere.2013.02.027 · Cited by 140
Kinetic degradation of chloramphenicol in water by UV/persulfate system
Tan, C., Fu, D., Gao, N., Qin, Q., Xu, Y., & Xiang, H. (2016) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2016.09.021 · Cited by 140
Wen, G., Wang, S., Ma, J., Huang, T., Liu, Z.-Q., Zhao, L., & Xu, J. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.05.002 · Cited by 131
Ni(OH)2 decorated rutile TiO2 for efficient removal of tetracycline from wastewater
Leong, S., Li, D., Hapgood, K., Zhang, X., & Wang, H. (2016) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.05.043 · Cited by 126
Ji, Q., Li, J., Xiong, Z., & Lai, B. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2016.12.128 · Cited by 125
Enhanced heterogeneous Fenton-like degradation of methylene blue by reduced CuFe 2 O 4
Qin, Q., Liu, Y., Li, X., Sun, T., & Xu, Y. (2018) · RSC Advances · doi:10.1039/c7ra12488k · Cited by 123
Wang, Z., Deng, D., & Yang, L. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.02.027 · Cited by 115
Jing, P., Li, J., Pan, L., Wang, J., Sun, X., & Liu, Q. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.11.015 · Cited by 96
Li, T., Cao, S., Yang, C., Chen, Y., Lv, X., & Fu, W. (2015) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.5b00266 · Cited by 87
Impact of activation methods on persulfate oxidation of methyl tert-butyl ether
Deng, D., Peng, L., Guan, M., & Kang, Y. (2013) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2013.10.042 · Cited by 71
Ionisation constants of ˙OH and HO˙2 in aqueous solution up to 200 °C. A pulse radiolysis study
Buxton, G. V., Wood, N. D., & Dyster, S. (1988) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19888401113 · Cited by 71
Hussain, I., Li, M., Zhang, Y., Huang, S., Hayat, W., Li, Y., Du, X., & Liu, G. (2017) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2017.07.051 · Cited by 57
Cited by
Zheng, X., Niu, X., Zhang, D., Lv, M., Ye, X., Ma, J., Lin, Z., & Fu, M. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132323 · Cited by 593
Liu, C., Dai, H., Tan, C., Pan, Q., Hu, F., & Peng, X. (2022) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2022.121326 · Cited by 502
Oxidative degradation of tetracycline using persulfate activated by N and Cu codoped biochar
Zhong, Q., Lin, Q., Huang, R., Fu, H., Zhang, X., Luo, H., & Xiao, R. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.122608 · Cited by 313
Bhat, A. P., & Gogate, P. R. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123657 · Cited by 308
Mn doped magnetic biochar as persulfate activator for the degradation of tetracycline
Huang, D., Zhang, Q., Zhang, C., Wang, R., Deng, R., Luo, H., Li, T., Li, J., Chen, S., & Liu, C. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.123532 · Cited by 304
Metadata
- Authors
- Li, Z., Guo, C., Lyu, J., Hu, Z., & Ge, M.
- Venue
- Journal of Hazardous Materials
- Publisher
- Elsevier BV
- Published
- 2019-07
- Volume
- 373
- Pages
- 85-96
- ISSN
- 0304-3894 (ISSN-L)
- OpenAlex
- W2924705267
- Cited by
- 430
- References
- 49
- FWCI
- 16.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.