Fibrillar collagen scoring by second harmonic microscopy: A new tool in the assessment of liver fibrosis
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Histological grading and staging of chronic hepatitis
Ishak, K., Baptista, A., Bianchi, L., Callea, F., De Groote, J., Gudat, F., Denk, H., Desmet, V., Korb, G., MacSween, R. N. M., et al. (1995) · Journal of Hepatology · doi:10.1016/0168-8278(95)80226-6 · Cited by 5,029 · cited 1×
“In order to determine the degree of fibrosis, several methods are based on the pathological examination of liver biopsies by a trained pathologist using numerical systems with increasing severity stages like Scheuer [4], Ishak [5] or Metavir [6] scores after ECM staining [7,8].”
MethodBataller, R., & Brenner, D. A. (2005) · Journal of Clinical Investigation · doi:10.1172/jci24282 · Cited by 4,958
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893 · cited 2×
“SHG makes the specific detection of supramolecules possible with high crystalline triple-helix structures deprived of centrosymmetry at microscopic and mesoscopic scales [11–14].”
BackgroundNatural history of liver fibrosis progression in patients with chronic hepatitis C
Poynard, T., Bedossa, P., & Opolon, P. (1997) · The Lancet · doi:10.1016/s0140-6736(96)07642-8 · Cited by 3,011
Bedossa, P. (1994) · Hepatology · doi:10.1002/hep.1840200104 · Cited by 2,003
Zipfel, W. R., Williams, R. M., Christie, R., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,676 · cited 1×
“SHG microscopy has been successfully employed in various models and has revealed its high potential for imaging and analyzing fibrillar collagen in unstained tissues [19–22].”
MethodClassification of chronic viral hepatitis: a need for reassessment
Scheuer, P. J. (1991) · Journal of Hepatology · doi:10.1016/0168-8278(91)90084-o · Cited by 1,576 · cited 1×
“In order to determine the degree of fibrosis, several methods are based on the pathological examination of liver biopsies by a trained pathologist using numerical systems with increasing severity stages like Scheuer [4], Ishak [5] or Metavir [6] scores after ECM staining [7,8].”
MethodBataller, R. (2005) · Journal of Clinical Investigation · doi:10.1172/jci200524282c1 · Cited by 1,472
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326 · cited 1×
“myosin fibers and microtubules, fibrillar collagen can generate a two-photon coherent process selectively collected and recorded at precisely half-wavelength of excitation which is characteristic of the SHG signature [15–18].”
BackgroundMultiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265 · cited 1×
“SHG makes the specific detection of supramolecules possible with high crystalline triple-helix structures deprived of centrosymmetry at microscopic and mesoscopic scales [11–14].”
BackgroundCampagnola, P. J., Millard, A. C., Terasaki, M., Hoppe, P. E., Malone, C. J., & Mohler, W. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75414-3 · Cited by 917 · cited 1×
“myosin fibers and microtubules, fibrillar collagen can generate a two-photon coherent process selectively collected and recorded at precisely half-wavelength of excitation which is characteristic of the SHG signature [15–18].”
BackgroundDynamic imaging of collagen and its modulation in tumors in vivo using second-harmonic generation
Brown, E., McKee, T., diTomaso, E., Pluen, A., Seed, B., Boucher, Y., & Jain, R. K. (2003) · Nature Medicine · doi:10.1038/nm879 · Cited by 836
Evaluation of Liver Fibrosis: A Concise Review
Afdhal, N. H., & Nunes, D. (2004) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2004.30110.x · Cited by 622 · cited 1×
“The progression of human fibrosis may lead to cirrhosis and cancer with clinical complications followed by high morbidity and mortality rates particularly in chronic hepatitis B or C virus (HBV, HCV) infections [2,3].”
BackgroundProjecting future complications of chronic hepatitis C in the United States
Davis, G. L., Albright, J. E., Cook, S. F., & Rosenberg, D. M. (2003) · Liver Transplantation · doi:10.1053/jlts.2003.50073 · Cited by 576
Sources of variability in histological scoring of chronic viral hepatitis†
Rousselet, M., Michalak, S., Dupré, F., Croué, A., Bedossa, P., Saint‐André, J., & Calès, P. (2005) · Hepatology · doi:10.1002/hep.20535 · Cited by 540 · cited 1×
“A recent study showed significant disparities in the scoring of fibrosis between observers using the Metavir system, which increased between junior and qualified-senior academic pathologists [25].”
ResultA comparison of fibrosis progression in chronic liver diseases
Poynard, T., Mathurin, P., Lai, C.-L., Guyader, D., Poupon, R., Tainturier, M.-H., Myers, R. P., Muntenau, M., Ratziu, V., Manns, M., et al. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(02)00413-0 · Cited by 474 · cited 1×
“In order to determine the degree of fibrosis, several methods are based on the pathological examination of liver biopsies by a trained pathologist using numerical systems with increasing severity stages like Scheuer [4], Ishak [5] or Metavir [6] scores after ECM staining [7,8].”
MethodSelf-citation3-Dimensional imaging of collagen using second harmonic generation
Cox, G., Kable, E., Jones, A., Fraser, I., Manconi, F., & Gorrell, M. D. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00576-2 · Cited by 430 · cited 1×
“SHG microscopy has been successfully employed in various models and has revealed its high potential for imaging and analyzing fibrillar collagen in unstained tissues [19–22].”
MethodSecond harmonic imaging and scoring of collagen in fibrotic tissues
Strupler, M., Pena, A.-M., Hernest, M., Tharaux, P.-L., Martin, J.-L., Beaurepaire, E., & Schanne-Klein, M.-C. (2007) · Optics Express · doi:10.1364/oe.15.004054 · Cited by 273 · cited 1×
“Recent data also suggested that SHG microscopy could be an interesting approach in the assessment of fibro-proliferative diseases [23,24].”
BackgroundBENYON, R. C., & IREDALE, J. P. (2000) · Gut · doi:10.1136/gut.46.4.443 · Cited by 262
Second-harmonic imaging microscopy of living cells
Campagnola, P. J., Clark, H. A., Mohler, W. A., Lewis, A., & Loew, L. M. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1383294 · Cited by 244 · cited 1×
“myosin fibers and microtubules, fibrillar collagen can generate a two-photon coherent process selectively collected and recorded at precisely half-wavelength of excitation which is characteristic of the SHG signature [15–18].”
BackgroundReversibility of liver fibrosis and cirrhosis following treatment for hepatitis C
Arthur, M. J. P. (2002) · Gastroenterology · doi:10.1053/gast.2002.33367 · Cited by 241 · cited 1×
“Although essential factors conditioning fibrosis reversibility are not well known, a few treatments are currently under study [26,27] and could be precisely evaluated using SHG scoring.”
BackgroundPilette, C., Rousselet, M. C., Bedossa, P., Chappard, D., Oberti, F., Rifflet, H., Maïga, M. Y., Gallois, Y., & Calès, P. (1998) · Journal of Hepatology · doi:10.1016/s0168-8278(98)80318-8 · Cited by 205
Pena, A., Fabre, A., Débarre, D., Marchal-Sommé, J., Crestani, B., Martin, J. L., Beaurepaire, E., & Schanne‐Klein, M. (2006) · Microscopy Research and Technique · doi:10.1002/jemt.20400 · Cited by 151 · cited 1×
“Recent data also suggested that SHG microscopy could be an interesting approach in the assessment of fibro-proliferative diseases [23,24].”
BackgroundProgression of fibrosis in advanced chronic hepatitis C: Evaluation by morphometric image analysis†
Goodman, Z. D., Becker, R. L., Pockros, P. J., & Afdhal, N. H. (2007) · Hepatology · doi:10.1002/hep.21595 · Cited by 145 · cited 1×
“An alternative to the numerical scoring systems relies on a direct measurement of the amount of fibrotic deposits by morphometric image analysis [9,10].”
BackgroundMicrometer scale Ex Vivo multiphoton imaging of unstained arterial wall structure
Boulesteix, T., Pena, A., Pagès, N., Godeau, G., Sauviat, M., Beaurepaire, E., & Schanne‐Klein, M. (2005) · Cytometry Part A · doi:10.1002/cyto.a.20196 · Cited by 114
Collagen and myosin characterization by orientation field second harmonic microscopy
Odin, C., Guilbert, T., Al-Kilani, A., Boryskina, O. P., Fleury, V., & Grand, Y. L. (2008) · Optics Express · doi:10.1364/oe.16.016151 · Cited by 90
Self-citationGeorgiou, E. T., Theodossiou, T. A., Hovhannisyan, V., Politopoulos, K., Rapti, G., & Yova, D. M. (2000) · Optics Communications · doi:10.1016/s0030-4018(00)00504-6 · Cited by 87 · cited 1×
“myosin fibers and microtubules, fibrillar collagen can generate a two-photon coherent process selectively collected and recorded at precisely half-wavelength of excitation which is characteristic of the SHG signature [15–18].”
BackgroundOptimization of second-harmonic generation microscopy
Gauderon, R., Lukins, P. B., & Sheppard, C. J. R. (2001) · Micron · doi:10.1016/s0968-4328(00)00066-4 · Cited by 80 · cited 1×
“SHG makes the specific detection of supramolecules possible with high crystalline triple-helix structures deprived of centrosymmetry at microscopic and mesoscopic scales [11–14].”
BackgroundOrientation fields of nonlinear biological fibrils by second harmonic generation microscopy
Odin, C., Grand, Y. L., Renault, A., Gailhouste, L., & Baffet, G. (2007) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01868.x · Cited by 72 · cited 1×
“Journal of Hepatology 201 materials [28,29].”
Self-citation
Cited by
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
“However, immunohistochemical evaluation of cellular markers such as smooth muscle actin expression for hepatic stellate cell activation, cytokeratin 7 for labeling ductular proliferation or CD34 for visualization of sinusoidal endothelial capillarization or the use of two-photon and second harmonic generation fluoresc…”
BackgroundDal-Secco, D., Wang, J., Zeng, Z., Kolaczkowska, E., Wong, C. H. Y., Petri, B., Ransohoff, R. M., Charo, I. F., Jenne, C. N., & Kubes, P. (2015) · Journal of Experimental Medicine · doi:10.1084/jem.20141539 · Cited by 452
Jenkins, R. G., Moore, B. B., Chambers, R. C., Eickelberg, O., Königshoff, M., Kolb, M., Laurent, G. J., Nanthakumar, C. B., Olman, M. A., Pardo, A., et al. (2017) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2017-0096st · Cited by 435
Limitations of non-invasive tests for assessment of liver fibrosis
Patel, K., & Sebastiani, G. (2020) · JHEP Reports · doi:10.1016/j.jhepr.2020.100067 · Cited by 317
Engineering and physical sciences in oncology: challenges and opportunities
Mitchell, M. J., Jain, R. K., & Langer, R. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.83 · Cited by 273
Metadata
- Authors
- Gailhouste, L., Grand, Y. L., Odin, C., Guyader, D., Turlin, B., Ezan, F., Désille, Y., Guilbert, T., Bessard, A., Frémin, C., Theret, N., & Baffet, G.
- Venue
- Journal of Hepatology
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 52
- Issue
- 3
- Pages
- 398-406
- ISSN
- 0168-8278 (ISSN-L)
- OpenAlex
- W1976377883
- Cited by
- 192
- References
- 29
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.