The DOI matches its Crossref record.
Air sampling methods to evaluate microbial contamination in operating theatres: results of a comparative study in an orthopaedics department
Abstract
Aim To evaluate the level of microbial contamination of air in operating theatres using active [i.e. surface air system (SAS)] and passive [i.e. index of microbial air contamination (IMA) and nitrocellulose membranes positioned near the wound] sampling systems. Methods Sampling was performed between January 2010 and January 2011 in the operating theatre of the orthopaedics department in a university hospital in Southern Italy. Findings During surgery, the mean bacterial loads recorded were 2232.9 colony-forming units (cfu)/m(2)/h with the IMA method, 123.2 cfu/m(3) with the SAS method and 2768.2 cfu/m(2)/h with the nitrocellulose membranes. Correlation was found between the results of the three methods. Staphylococcus aureus was detected in 12 of 60 operations (20%) with the membranes, five (8.3%) operations with the SAS method, and three operations (5%) with the IMA method. Conclusion Use of nitrocellulose membranes placed near a wound is a valid method for measuring the microbial contamination of air. This method was more sensitive than the IMA method and was not subject to any calibration bias, unlike active air monitoring systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A study published in 2012 found that levels of recorded microbial contamination in operating rooms are also influenced by external factors such as the point of collection in the operating room.
“A study published in 2012 found that levels of recorded microbial contamination in operating rooms are also influenced by external factors such as the point of collection in the operating room [32]”
From Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres (2012) · cites this paper as [32]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 29
- Mangram, 1999, Guideline for prevention of surgical site infection, 1999. Hospital Infection Control Practices Advisory Committee, Infect Control Hosp Epidemiol, 20, 250, 10.1086/501620 · DOI
- Charnley, 1972, Post operative infection after total hip replacement with special reference to air contamination in the operating room, Clin Orthop, 87, 167, 10.1097/00003086-197209000-00020 · DOI · Paper page
- Lidwell, 1988, Air, antibiotics and sepsis in replacement joints, J Hosp Infect, 11, 18, 10.1016/0195-6701(88)90020-5 · DOI
- Gosden, 1998, Importance of air quality and related factors in the prevention of infection in orthopaedic implant surgery, J Hosp Infect, 39, 173, 10.1016/S0195-6701(98)90255-9 · DOI · Paper page
- Whyte, 1982, The importance of airborne bacterial contamination of wounds, J Hosp Infect, 3, 123, 10.1016/0195-6701(82)90004-4 · DOI
- Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption. Official Journal of the European Community 1998;L330:32–54.
- Pasquarella, 2008, Air microbial sampling: the state of the art, Ig Sanita Pubbl, 64, 79
- Blomquist, 1994, Sampling of biological particles, Analyst, 119, 53, 10.1039/an9941900053 · DOI
- Friberg, 1999, Inconsistent correlation between aerobic bacterial surface and air counts in operating rooms with ultra clean laminar air flows: proposal of a new bacteriological standard for surface contamination, J Hosp Infect, 42, 287, 10.1053/jhin.1998.0598 · DOI
- Orpianesi, 1983, Evaluation of microbial contamination in a hospital environment. Comparison between the surface air system and the traditional method, Nuovi Ann Ig Microbiol, 34, 171
- Perdelli, 2000, Relationship between settling microbial load and suspended microbial load in operating rooms, Ann Ig, 12, 373
- Whyte, 1986, Sterility assurance and models for assessing airborne bacterial contamination, J Parenter Sci Technol, 40, 188
- Petti, 2003, Comparison between different methods to monitor the microbial level of indoor air contamination in the dental office, Ann Ig, 15, 725
- Sayer, 1972, Hospital airborne bacteria as estimated by the Andersen sampler versus the gravity settling culture plate, Am J Clin Pathol, 58, 558, 10.1093/ajcp/58.5.558 · DOI · Paper page
- Friberg, 1999, Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent ventilation: an experimental study, J Hosp Infect, 42, 61, 10.1053/jhin.1998.0542 · DOI · Paper page
- Pasquarella, 2003, Lack of influence of body exhaust gowns on aerobic bacterial surface counts in a mixed ventilation operating theatre. A study of 62 hip arthroplasties, J Hosp Infect, 54, 2, 10.1016/S0195-6701(03)00077-X · DOI
- Pasquarella, 2007, A mobile laminar airflow unit to reduce air bacterial contamination at surgical area in a conventionally ventilated operating theatre, J Hosp Infect, 66, 313, 10.1016/j.jhin.2007.05.022 · DOI
- Pasquarella, 2000, The index of microbial air contamination, J Hosp Infect, 46, 241, 10.1053/jhin.2000.0820 · DOI
- Fish, 1992, Antibiotic-impregnated cement use in U.S. hospitals, Am J Hosp Pharm, 49, 2469
- Jackson, 2000, Limited role of direct exchange arthroplasty in the treatment of infected total hip replacements, Clin Orthop, 381, 101, 10.1097/00003086-200012000-00012 · DOI
- Hoffman, 2001, Air sampling: settle plates or slit samplers?, J Hosp Infect, 49, 299, 10.1053/jhin.2001.1102 · DOI
- Whyte, 1996, In support of settle plates, PDA J Pharm Scien Technol, 50, 201
- Salgado, 2007, Higher risk of failure of methicillin-resistant Staphylococcus aureus prosthetic joint infections, Clin Orthop Relat Res, 461, 48, 10.1097/BLO.0b013e3181123d4e · DOI
- Tattevin, 1999, Prosthetic joint infection: when can prosthesis salvage be considered?, Clin Infect Dis, 29, 292, 10.1086/520202 · DOI
- Zimmerli, 2003, Management of infection associated with prosthetic joints, Infection, 31, 99, 10.1007/s15010-002-3079-9 · DOI
- Rogers, 2009, Coagulase-negative staphylococcal infections, Infect Dis Clin North Am, 23, 73, 10.1016/j.idc.2008.10.001 · DOI
- Pristoupil, 1969, On the mechanism of adsorption of proteins to nitrocellulose in membrane chromatography, J Chromatogr, 42, 367, 10.1016/S0021-9673(01)80636-1 · DOI
- Verhoeff, 1990, Enumeration and identification of airborne viable mould propagules in houses. A field comparison of selected techniques, Allergy, 45, 275, 10.1111/j.1398-9995.1990.tb00496.x · DOI · Paper page
- Asefa, 2009, The performance of SAS-super-180 air sampler and settle plates for assessing viable fungal particles in the air of dry-cured meat production facility, Food Control, 20, 997, 10.1016/j.foodcont.2008.11.011 · DOI · Paper page
Cited by
Sorted by citations
Napoli, C., Marcotrigiano, V., & Montagna, M. T. (2012) · BMC Public Health · doi:10.1186/1471-2458-12-594 · Cited by 244
“A study published in 2012 found that levels of recorded microbial contamination in operating rooms are also influenced by external factors such as the point of collection in the operating room [32]; so confirming previous reports in which, with the passive sampling method, higher counts were found on settle plates nea…”
ResultSelf-citationY, V., & S, U. (2019) · Journal of Pure and Applied Microbiology · doi:10.22207/jpam.13.1.25 · Cited by 6
Metadata
- Authors
- Napoli, C., Tafuri, S., Montenegro, L., Cassano, M., Notarnicola, A., Lattarulo, S., Montagna, M. T., & Moretti, B.
- Affiliations
- University of Bari Aldo Moro (IT)
- Corresponding author
- Napoli, C.
- Venue
- Journal of Hospital Infection
- Publisher
- Elsevier BV
- Published
- 2012-02
- Volume
- 80
- Issue
- 2
- Pages
- 128-132
- ISSN
- 0195-6701 (ISSN-L)
- OpenAlex
- W2075805088
- Cited by
- 56
- References
- 0
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 7 · 2020: 2 · 2019: 5 · 2018: 7 · 2017: 4 · 2016: 2 · 2015: 1 · 2014: 8 · 2013: 4 · 2012: 2
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hospital Infection (publishedVersion)
- PubMed (publishedVersion)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- airborne microbial contamination, Staphylococcus aureus, orthopedic surgery, surgical site infection, hospital infection control
- MeSH terms
- Air Microbiology, Bacteria, Hospitals, University, Humans, Italy, Operating Rooms, Bacterial Load
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review