Aquatic reservoir-associated outbreaks of multi-drug-resistant bacteria: a hospital outbreak report of Pseudomonas aeruginosa in perspective from the Dutch national surveillance databases

Debast, S.B., van den Bos-Kromhout, M.I., de Vries-van Rossum, S.V., Abma-Blatter, S.E.M., Notermans, D.W., Kluytmans, J.A.J.W., Immeker, B., Zuur, J.K., Hijmering, M.L., Bergwerff, A.A., Bruins, M.J., Bisselink, Y.J.W.M., Hendrickx, A.P.A., Rossen, J.W.A. · 2025 · Journal of Hospital Infection

Abstract

BACKGROUND: Water fixtures can be involved in hospital outbreaks with multi-resistant pathogens. AIM: To document an outbreak of a Verona integron-encoded metallo-β-lactamase type 2-producing carbapenem-resistant Pseudomonas aeruginosa (CRPA-VIM) and evaluate infection control measures. Additionally, to overview waterborne outbreaks involving multi-resistant pathogens in Dutch healthcare institutions. METHODS: Epidemiologic analysis, selective culturing, PCR, and whole-genome sequencing (WGS) identified the outbreak sources. National surveillance databases were consulted. FINDINGS: In December 2023, three ICU patients tested positive for CRPA-VIM with multi-locus sequence type (MLST) ST111. Contaminated sinks were identified as the source. Despite interventions, a new cluster of five CRPA-VIM-positive patients emerged in March-April 2024. WGS linked this to a decommissioned sink (November 2021) and two patients (December 2021 and April 2023). Contact tracing and source investigations found no interpatient transmission; sinks were identified as the sole source. Measures, including contact precautions, intensified cleaning and hygiene procedures, retraining, installing and frequently replacing splash- and aerosol-reducing inlets, and faucet modifications failed to halt the transmission. No new cases occurred after the removal of all water fixtures in the ICU patient rooms. The outbreak strain was unique to the hospital and showed no genetic clustering in the national surveillance. Nationally, three to five waterborne outbreaks with highly resistant micro-organisms in hospitals are reported annually. CONCLUSIONS: CRPA-VIM was transmitted from sinks to ICU patients without interpatient transmission. Infection control requires comprehensive surveillance of patients and the environment. A water-restricted and drain-free environment ended the outbreak. Future hospital design should minimize contamination from drains and sinks to reduce the nosocomial infection risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jhin.2025.05.024

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 35

  1. Cusack, 2024, Practical lessons on antimicrobial therapy for critically ill patients, Antibiotics, 13, 162, 10.3390/antibiotics13020162 · DOI
  2. Van Ingen, 2017, Global outbreak of severe Mycobacterium chimaera disease after cardiac surgery: a molecular epidemiological study, Lancet Inf Dis, 17, 1033, 10.1016/S1473-3099(17)30324-9 · DOI · Paper page
  3. Decker, 2014, Hospital water and opportunities for infection prevention, Curr Inf Dis Rep, 16, 1
  4. De Geyter, 2017, The sink as a potential source of transmission of carbapenemase-producing Enterobacteriaceae in the intensive care unit, Antimicrob Resist Infect Control, 6, 24, 10.1186/s13756-017-0182-3 · doi:10.1186/s13756-017-0182-3
  5. Volling, 2021, Are sink drainage systems a reservoir for hospital-acquired Gammaproteobacteria colonization and infection? A systematic review, Open Forum Infect Dis, 8, 10.1093/ofid/ofaa590 · DOI
  6. Thi, 2020, Pseudomonas aeruginosa biofilms, Int J Mol Sci, 21, 8671, 10.3390/ijms21228671 · DOI · Paper page
  7. Couchoud, 2023, Genome-based typing reveals rare events of patient contamination with Pseudomonas aeruginosa from other patients and sink traps in a medical intensive care unit, J Hosp Inf, 134, 63, 10.1016/j.jhin.2023.01.010 · DOI
  8. Van Duin, 2017, The global epidemiology of carbapenemase-producing Enterobacteriaceae, Virulence, 8, 460, 10.1080/21505594.2016.1222343 · DOI · Paper page
  9. Gales, 2023, Incidence of ESBLs and carbapenemases among Enterobacterales and carbapenemases in Pseudomonas aeruginosa isolates collected globally: results from ATLAS 2017–2019, J Antimicrob Chemother, 78, 1606, 10.1093/jac/dkad127 · DOI
  10. Bruins, 2020, VIM-carbapenemase-producing Escherichia coli in a residential care home in the Netherlands, J Hosp Inf, 104, 20, 10.1016/j.jhin.2019.08.012 · doi:10.1016/j.jhin.2019.08.012
  11. Van der Zee, 2014, Multi-centre evaluation of real-time multiplex PCR for detection of carbapenemase genes OXA-48, VIM, IMP, NDM and KPC, BMC Infect Dis, 14, 27, 10.1186/1471-2334-14-27 · DOI
  12. Tönnies, 2021, Establishment and Evaluation of a Core Genome Multilocus Sequence Typing Scheme for Whole-Genome Sequence-Based Typing of Pseudomonas aeruginosa, J Clin Microbiol, 59, 10.1128/JCM.01987-20 · doi:10.1128/jcm.01987-20
  13. Zankari, 2012, Identification of acquired antimicrobial resistance genes, J Antimicrob Chemother, 67, 2640, 10.1093/jac/dks261 · DOI · Paper page
  14. Pirzadian, 2021, Dutch CPE surveillance Study Group. National surveillance pilot study unveils a multicenter, clonal outbreak of VIM-2-producing Pseudomonas aeruginosa ST111 in the Netherlands between 2015 and 2017, Sci Rep, 11, 10.1038/s41598-021-00205-w · DOI
  15. Van der Zwaluw, 2015, The carbapenem inactivation method (CIM), a simple and low-cost alternative for the Carba NP test to assess phenotypic carbapenemase activity in gram-negative rods, PloS One, 10, 10.1371/journal.pone.0123690 · DOI · Paper page
  16. Rossel, 2024, Tracing the origin of NDM-1-producing and extensively drug-resistant Pseudomonas aeruginosa ST357 in the Netherlands, BMC Infect Dis, 24, 817, 10.1186/s12879-024-09722-1 · DOI
  17. Woudt, 2023, Description of a nationwide structure for monitoring nosocomial outbreaks of (highly resistant) microorganisms in the Netherlands: characteristics of outbreaks in 2012-2021, Antimicrob Resist Infect Control, 12, 143, 10.1186/s13756-023-01350-9 · DOI
  18. Moloney, 2020, Whole-genome sequencing identifies highly related Pseudomonas aeruginosa strains in multiple washbasin U-bends at several locations in one hospital: evidence for trafficking of potential pathogens via wastewater pipes, J Hosp Inf, 104, 484, 10.1016/j.jhin.2019.11.005 · doi:10.1016/j.jhin.2019.11.005
  19. Wu, 2025, Extended-spectrum β-lactamase-producing bacteria from hospital wastewater pipes: isolation, characterization and biofilm control using common disinfectants, J Hosp Inf, 156, 34, 10.1016/j.jhin.2024.11.013 · DOI
  20. Fucini, 2023, Sinks in patient rooms in ICUs are associated with higher rates of hospital-acquired infection: a retrospective analysis of 552 ICUs, J Hosp Infect, 139, 99, 10.1016/j.jhin.2023.05.018 · doi:10.1016/j.jhin.2023.05.018
  21. Salm, 2016, Prolonged outbreak of clonal MDR Pseudomonas aeruginosa on an intensive care unit: contaminated sinks and contamination of ultra-filtrate bags as possible route of transmission?, Antimicrob Resist Infect Control, 5, 1, 10.1186/s13756-016-0157-9 · DOI
  22. Parcell, 2018, Pseudomonas aeruginosa intensive care unit outbreak: winnowing of transmissions with molecular and genomic typing, J Hosp Inf, 98, 282, 10.1016/j.jhin.2017.12.005 · doi:10.1016/j.jhin.2017.12.005
  23. Umezawa, 2015, Outbreak of drug-resistant Acinetobacter baumannii ST219 caused by oral care using tap water from contaminated hand hygiene sinks as a reservoir, Am J Inf Control, 43, 1249, 10.1016/j.ajic.2015.06.016 · doi:10.1016/j.ajic.2015.06.016
  24. Knoester, 2014, An integrated approach to control a prolonged outbreak of multidrug-resistant Pseudomonas aeruginosa in an intensive care unit, Clin Microbiol Inf, 20, O207, 10.1111/1469-0691.12372 · DOI
  25. Rath, 2024, Retrospective genome-oriented analysis reveals low transmission rate of multidrug-resistant Pseudomonas aeruginosa from contaminated toilets at a bone marrow transplant unit, J Hosp Inf, 150, 96e104, 10.1016/j.jhin.2024.05.015 · doi:10.1016/j.jhin.2024.05.015
  26. Mayr, 2017, Nosocomial outbreak of extensively drug-resistant Pseudomonas aeruginosa associated with aromatherapy, Am J Inf Control, 45, 453, 10.1016/j.ajic.2016.11.002 · DOI
  27. Blanc, 2016, Hand soap contamination by Pseudomonas aeruginosa in a tertiary care hospital: no evidence of impact on patients, J Hosp Inf, 93, 63, 10.1016/j.jhin.2016.02.010 · DOI
  28. Gbaguidi-Haore, 2018, A bundle of measures to control an outbreak of Pseudomonas aeruginosa associated with P-trap contamination, Inf Control Hosp Epidemiol, 39, 164, 10.1017/ice.2017.304 · doi:10.1017/ice.2017.304
  29. Cole, 2019, Mitigation of microbial contamination from waste water and aerosolization by sink design, J Hosp Inf, 103, 193, 10.1016/j.jhin.2019.05.011 · doi:10.1016/j.jhin.2019.05.011
  30. Catho, 2024, Controlling the hospital aquatic reservoir of multidrug-resistant organisms: a cross-sectional study followed by a nested randomized trial of sink decontamination, Clin Microbiol Inf, 30, 1049, 10.1016/j.cmi.2024.05.008 · doi:10.1016/j.cmi.2024.05.008
  31. Ledwoch, 2020, It's a trap! The development of a versatile drain biofilm model and its susceptibility to disinfection, J Hosp Inf, 106, 757, 10.1016/j.jhin.2020.08.010 · doi:10.1016/j.jhin.2020.08.010
  32. Anantharajah, 2024, Long-term intensive care unit outbreak of carbapenamase-producing organisms associated with contaminated sink drains, J Hosp Inf, 143, 38, 10.1016/j.jhin.2023.10.010 · DOI
  33. Fucini, 2024, Sink interventions in the ICU to reduce risk of infection or colonization with Gram-negative pathogens: a systematic review of the literature, J Hosp Infect, 143, 82, 10.1016/j.jhin.2023.10.011 · doi:10.1016/j.jhin.2023.10.011
  34. Garvey, 2019, Tap out: reducing waterborne Pseudomonas aeruginosa transmission in an intensive care unit, J Hosp Inf, 102, 75, 10.1016/j.jhin.2018.07.039 · doi:10.1016/j.jhin.2018.07.039
  35. Kossow, 2017, Control of multidrug-resistant Pseudomonas aeruginosa in allogeneic hematopoietic stem cell transplant recipients by a novel bundle including remodeling of sanitary and water supply systems, Clin Inf Dis, 65, 935, 10.1093/cid/cix465 · doi:10.1093/cid/cix465

Cited by

Metadata

Authors
Debast, S. B., van den Bos-Kromhout, M. I., de Vries-van Rossum, S. V., Abma-Blatter, S. E. M., Notermans, D. W., Kluytmans, J. A. J. W., Immeker, B., Zuur, J. K., Hijmering, M. L., Bergwerff, A. A., Bruins, M. J., Bisselink, Y. J. W. M., Hendrickx, A. P. A., & Rossen, J. W. A.
Venue
Journal of Hospital Infection
Publisher
Elsevier BV
Published
2025-08
Volume
162
Pages
310-318
ISSN
0195-6701
Cited by
16
References
0
Language
en
Licence
Funders
  • Rijksinstituut voor Volksgezondheid en Milieu
  • Amsterdam University Medical Centers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.