The DOI matches its Crossref record.
Aquatic reservoir-associated outbreaks of multi-drug-resistant bacteria: a hospital outbreak report of Pseudomonas aeruginosa in perspective from the Dutch national surveillance databases
Abstract
BACKGROUND: Water fixtures can be involved in hospital outbreaks with multi-resistant pathogens. AIM: To document an outbreak of a Verona integron-encoded metallo-β-lactamase type 2-producing carbapenem-resistant Pseudomonas aeruginosa (CRPA-VIM) and evaluate infection control measures. Additionally, to overview waterborne outbreaks involving multi-resistant pathogens in Dutch healthcare institutions. METHODS: Epidemiologic analysis, selective culturing, PCR, and whole-genome sequencing (WGS) identified the outbreak sources. National surveillance databases were consulted. FINDINGS: In December 2023, three ICU patients tested positive for CRPA-VIM with multi-locus sequence type (MLST) ST111. Contaminated sinks were identified as the source. Despite interventions, a new cluster of five CRPA-VIM-positive patients emerged in March-April 2024. WGS linked this to a decommissioned sink (November 2021) and two patients (December 2021 and April 2023). Contact tracing and source investigations found no interpatient transmission; sinks were identified as the sole source. Measures, including contact precautions, intensified cleaning and hygiene procedures, retraining, installing and frequently replacing splash- and aerosol-reducing inlets, and faucet modifications failed to halt the transmission. No new cases occurred after the removal of all water fixtures in the ICU patient rooms. The outbreak strain was unique to the hospital and showed no genetic clustering in the national surveillance. Nationally, three to five waterborne outbreaks with highly resistant micro-organisms in hospitals are reported annually. CONCLUSIONS: CRPA-VIM was transmitted from sinks to ICU patients without interpatient transmission. Infection control requires comprehensive surveillance of patients and the environment. A water-restricted and drain-free environment ended the outbreak. Future hospital design should minimize contamination from drains and sinks to reduce the nosocomial infection risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Whole genome studies repeatedly link isolates from patients to drains and identify high-risk clones such as ST111 and ST235, as well as carbapenemase-producing strains in hospital water systems [293,294,295].”
From Understanding Pseudomonas aeruginosa Biofilms: Quorum Sensing, c-di-GMP Signaling, and Emerging Antibiofilm Approaches (2026) · cites this paper as [293]
In the citing paper
“P. aeruginosa persists in premise plumbing. Sink drains, U bends, and faucet components act as long-term reservoirs that seed patient rooms.”
From Understanding Pseudomonas aeruginosa Biofilms: Quorum Sensing, c-di-GMP Signaling, and Emerging Antibiofilm Approaches (2026) · cites this paper as [293]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 35
- Cusack, 2024, Practical lessons on antimicrobial therapy for critically ill patients, Antibiotics, 13, 162, 10.3390/antibiotics13020162 · DOI
- Van Ingen, 2017, Global outbreak of severe Mycobacterium chimaera disease after cardiac surgery: a molecular epidemiological study, Lancet Inf Dis, 17, 1033, 10.1016/S1473-3099(17)30324-9 · DOI · Paper page
- Decker, 2014, Hospital water and opportunities for infection prevention, Curr Inf Dis Rep, 16, 1
- De Geyter, 2017, The sink as a potential source of transmission of carbapenemase-producing Enterobacteriaceae in the intensive care unit, Antimicrob Resist Infect Control, 6, 24, 10.1186/s13756-017-0182-3 · doi:10.1186/s13756-017-0182-3
- Volling, 2021, Are sink drainage systems a reservoir for hospital-acquired Gammaproteobacteria colonization and infection? A systematic review, Open Forum Infect Dis, 8, 10.1093/ofid/ofaa590 · DOI
- Thi, 2020, Pseudomonas aeruginosa biofilms, Int J Mol Sci, 21, 8671, 10.3390/ijms21228671 · DOI · Paper page
- Couchoud, 2023, Genome-based typing reveals rare events of patient contamination with Pseudomonas aeruginosa from other patients and sink traps in a medical intensive care unit, J Hosp Inf, 134, 63, 10.1016/j.jhin.2023.01.010 · DOI
- Van Duin, 2017, The global epidemiology of carbapenemase-producing Enterobacteriaceae, Virulence, 8, 460, 10.1080/21505594.2016.1222343 · DOI · Paper page
- Gales, 2023, Incidence of ESBLs and carbapenemases among Enterobacterales and carbapenemases in Pseudomonas aeruginosa isolates collected globally: results from ATLAS 2017–2019, J Antimicrob Chemother, 78, 1606, 10.1093/jac/dkad127 · DOI
- Bruins, 2020, VIM-carbapenemase-producing Escherichia coli in a residential care home in the Netherlands, J Hosp Inf, 104, 20, 10.1016/j.jhin.2019.08.012 · doi:10.1016/j.jhin.2019.08.012
- Van der Zee, 2014, Multi-centre evaluation of real-time multiplex PCR for detection of carbapenemase genes OXA-48, VIM, IMP, NDM and KPC, BMC Infect Dis, 14, 27, 10.1186/1471-2334-14-27 · DOI
- Tönnies, 2021, Establishment and Evaluation of a Core Genome Multilocus Sequence Typing Scheme for Whole-Genome Sequence-Based Typing of Pseudomonas aeruginosa, J Clin Microbiol, 59, 10.1128/JCM.01987-20 · doi:10.1128/jcm.01987-20
- Zankari, 2012, Identification of acquired antimicrobial resistance genes, J Antimicrob Chemother, 67, 2640, 10.1093/jac/dks261 · DOI · Paper page
- Pirzadian, 2021, Dutch CPE surveillance Study Group. National surveillance pilot study unveils a multicenter, clonal outbreak of VIM-2-producing Pseudomonas aeruginosa ST111 in the Netherlands between 2015 and 2017, Sci Rep, 11, 10.1038/s41598-021-00205-w · DOI
- Van der Zwaluw, 2015, The carbapenem inactivation method (CIM), a simple and low-cost alternative for the Carba NP test to assess phenotypic carbapenemase activity in gram-negative rods, PloS One, 10, 10.1371/journal.pone.0123690 · DOI · Paper page
- Rossel, 2024, Tracing the origin of NDM-1-producing and extensively drug-resistant Pseudomonas aeruginosa ST357 in the Netherlands, BMC Infect Dis, 24, 817, 10.1186/s12879-024-09722-1 · DOI
- Woudt, 2023, Description of a nationwide structure for monitoring nosocomial outbreaks of (highly resistant) microorganisms in the Netherlands: characteristics of outbreaks in 2012-2021, Antimicrob Resist Infect Control, 12, 143, 10.1186/s13756-023-01350-9 · DOI
- Moloney, 2020, Whole-genome sequencing identifies highly related Pseudomonas aeruginosa strains in multiple washbasin U-bends at several locations in one hospital: evidence for trafficking of potential pathogens via wastewater pipes, J Hosp Inf, 104, 484, 10.1016/j.jhin.2019.11.005 · doi:10.1016/j.jhin.2019.11.005
- Wu, 2025, Extended-spectrum β-lactamase-producing bacteria from hospital wastewater pipes: isolation, characterization and biofilm control using common disinfectants, J Hosp Inf, 156, 34, 10.1016/j.jhin.2024.11.013 · DOI
- Fucini, 2023, Sinks in patient rooms in ICUs are associated with higher rates of hospital-acquired infection: a retrospective analysis of 552 ICUs, J Hosp Infect, 139, 99, 10.1016/j.jhin.2023.05.018 · doi:10.1016/j.jhin.2023.05.018
- Salm, 2016, Prolonged outbreak of clonal MDR Pseudomonas aeruginosa on an intensive care unit: contaminated sinks and contamination of ultra-filtrate bags as possible route of transmission?, Antimicrob Resist Infect Control, 5, 1, 10.1186/s13756-016-0157-9 · DOI
- Parcell, 2018, Pseudomonas aeruginosa intensive care unit outbreak: winnowing of transmissions with molecular and genomic typing, J Hosp Inf, 98, 282, 10.1016/j.jhin.2017.12.005 · doi:10.1016/j.jhin.2017.12.005
- Umezawa, 2015, Outbreak of drug-resistant Acinetobacter baumannii ST219 caused by oral care using tap water from contaminated hand hygiene sinks as a reservoir, Am J Inf Control, 43, 1249, 10.1016/j.ajic.2015.06.016 · doi:10.1016/j.ajic.2015.06.016
- Knoester, 2014, An integrated approach to control a prolonged outbreak of multidrug-resistant Pseudomonas aeruginosa in an intensive care unit, Clin Microbiol Inf, 20, O207, 10.1111/1469-0691.12372 · DOI
- Rath, 2024, Retrospective genome-oriented analysis reveals low transmission rate of multidrug-resistant Pseudomonas aeruginosa from contaminated toilets at a bone marrow transplant unit, J Hosp Inf, 150, 96e104, 10.1016/j.jhin.2024.05.015 · doi:10.1016/j.jhin.2024.05.015
- Mayr, 2017, Nosocomial outbreak of extensively drug-resistant Pseudomonas aeruginosa associated with aromatherapy, Am J Inf Control, 45, 453, 10.1016/j.ajic.2016.11.002 · DOI
- Blanc, 2016, Hand soap contamination by Pseudomonas aeruginosa in a tertiary care hospital: no evidence of impact on patients, J Hosp Inf, 93, 63, 10.1016/j.jhin.2016.02.010 · DOI
- Gbaguidi-Haore, 2018, A bundle of measures to control an outbreak of Pseudomonas aeruginosa associated with P-trap contamination, Inf Control Hosp Epidemiol, 39, 164, 10.1017/ice.2017.304 · doi:10.1017/ice.2017.304
- Cole, 2019, Mitigation of microbial contamination from waste water and aerosolization by sink design, J Hosp Inf, 103, 193, 10.1016/j.jhin.2019.05.011 · doi:10.1016/j.jhin.2019.05.011
- Catho, 2024, Controlling the hospital aquatic reservoir of multidrug-resistant organisms: a cross-sectional study followed by a nested randomized trial of sink decontamination, Clin Microbiol Inf, 30, 1049, 10.1016/j.cmi.2024.05.008 · doi:10.1016/j.cmi.2024.05.008
- Ledwoch, 2020, It's a trap! The development of a versatile drain biofilm model and its susceptibility to disinfection, J Hosp Inf, 106, 757, 10.1016/j.jhin.2020.08.010 · doi:10.1016/j.jhin.2020.08.010
- Anantharajah, 2024, Long-term intensive care unit outbreak of carbapenamase-producing organisms associated with contaminated sink drains, J Hosp Inf, 143, 38, 10.1016/j.jhin.2023.10.010 · DOI
- Fucini, 2024, Sink interventions in the ICU to reduce risk of infection or colonization with Gram-negative pathogens: a systematic review of the literature, J Hosp Infect, 143, 82, 10.1016/j.jhin.2023.10.011 · doi:10.1016/j.jhin.2023.10.011
- Garvey, 2019, Tap out: reducing waterborne Pseudomonas aeruginosa transmission in an intensive care unit, J Hosp Inf, 102, 75, 10.1016/j.jhin.2018.07.039 · doi:10.1016/j.jhin.2018.07.039
- Kossow, 2017, Control of multidrug-resistant Pseudomonas aeruginosa in allogeneic hematopoietic stem cell transplant recipients by a novel bundle including remodeling of sanitary and water supply systems, Clin Inf Dis, 65, 935, 10.1093/cid/cix465 · doi:10.1093/cid/cix465
Cited by
Elbehiry, A., Marzouk, E., Edrees, H. M., Ibrahem, M., Alzahrani, S., Anagreyyah, S., Abualola, H., Alghamdi, A., Alzahrani, A., Jaber, M., et al. (2026) · Microorganisms · doi:10.3390/microorganisms14010109 · Cited by 34
Metadata
- Authors
- Debast, S. B., van den Bos-Kromhout, M. I., de Vries-van Rossum, S. V., Abma-Blatter, S. E. M., Notermans, D. W., Kluytmans, J. A. J. W., Immeker, B., Zuur, J. K., Hijmering, M. L., Bergwerff, A. A., Bruins, M. J., Bisselink, Y. J. W. M., Hendrickx, A. P. A., & Rossen, J. W. A.
- Venue
- Journal of Hospital Infection
- Publisher
- Elsevier BV
- Published
- 2025-08
- Volume
- 162
- Pages
- 310-318
- ISSN
- 0195-6701
- Cited by
- 16
- References
- 0
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Funders
- Rijksinstituut voor Volksgezondheid en Milieu
- Amsterdam University Medical Centers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.