Assessment of Sensibility after Nerve Injury and Repair: A Systematic Review of Evidence for Validity, Reliability and Responsiveness of Tests
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Recovery of sensibility after peripheral nerve injury and repair needs to be assessed using psychometrically robust measures. In this study the literature was reviewed to identify what tests are available to quantify sensibility and to assess their validity, reliability and responsiveness. The databases Medline, CINAHL, Embase and AMED were searched for studies reporting the psychometric properties of sensibility tests. While there is a plethora of tests and studies reporting the outcomes after peripheral nerve suture only a few of the tests have evidence of validity, reliability and responsiveness. Currently the touch threshold test using monofilaments such as the Weinstein Enhanced Sensory Test (WEST) or Semmes–Weinstein Monofilament Test (SWMT) and the shape–texture identification (STI™) test for tactile gnosis are the only tests which meet criteria for a standardized test and have had their psychometric properties evaluated and quantified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Health Measurement Scales: A Practical Guide to Their Development and Use
Streiner, D. L., Norman, G. R., & Cairney, J. (1989) · Cited by 9,595
Current Problems of Lower Vertebrate Phylogeny
Romanes, G. J. (1969) · Journal of Anatomy · Cited by 1,830
Surgery of the peripheral nerve
Harrison, D. H. (1989) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(89)90093-3 · Cited by 807
Surgery of the peripheral nerve
(2009) · Operative Orthopaedics: The Stanmore Guide · doi:10.1201/b13554-10 · Cited by 645
OBJECTIVE METHODS FOR DETERMINING THE FUNCTIONAL VALUE OF SENSIBILITY IN THE HAND
Moberg, E. (1958) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.40b3.454 · Cited by 553 · cited 1×
“Tests to assess object, shape or texture identification (stereognosis, tactile gnosis) Moberg (1958) identified the need to quantify the functional value of touch by devising a test which involved picking up small objects with and without vision.”
BackgroundJohnson, K. O., & Phillips, J. R. (1981) · Journal of Neurophysiology · doi:10.1152/jn.1981.46.6.1177 · Cited by 537 · cited 3×
“The GOT has only been tested in patients with trigeminal nerve repair (van Boven and Johnson, 1994b) and on the hand of healthy subjects (Tremblay et al., 2000).”
MethodParry, C. B. W. (1981) · Injury · doi:10.1016/0020-1383(81)90228-x · Cited by 468
Van Boven, R. W., & Johnson, K. O. (1994) · Neurology · doi:10.1212/wnl.44.12.2361 · Cited by 419 · cited 2×
“The GOT has only been tested in patients with trigeminal nerve repair (van Boven and Johnson, 1994b) and on the hand of healthy subjects (Tremblay et al., 2000).”
BackgroundMethodReliability of two-point discrimination measurements
Dellon, A. L., Mackinnon, S. E., & Crosby, P. M. (1987) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(87)80049-7 · Cited by 303 · cited 2×
“Two-point discrimination (static 2PD and moving 2PD) Disk-Criminatort (Post Box 16392, Baltimore, MD21210) Concurrent validity: Correlation between S2PD and object recognition (number of objects recognised) r 1⁄4 0:777 and mean recognition time r 1⁄4 0:356 (Dellon and Kallman, 1983) Inter-tester reliability of static…”
MethodResultInfluential
Cited by
Hand function after nerve repair
Lundborg, G., & Rosén, B. (2007) · Acta Physiologica · doi:10.1111/j.1748-1716.2006.01653.x · Cited by 249
“It is important that 2PD results always are accompanied by a detailed description as to how the test was performed since the amount of pressure towards the skin can influence the result considerably (Jerosch-Herold 2005, Lundborg & Rosen 2004).”
InfluentialLindert, J., Bain, P. A., Kubzansky, L. D., & Stein, C. (2015) · The European Journal of Public Health · doi:10.1093/eurpub/cku193 · Cited by 246
Reliability of intraoral quantitative sensory testing (QST)
Pigg, M., Baad-Hansen, L., Svensson, P., Drangsholt, M., & List, T. (2010) · Pain · doi:10.1016/j.pain.2009.10.024 · Cited by 192
“thresholds for touch, cold, and heat [6,10,17,18] and for noxious stimuli [26].”
BackgroundTong, J., Mao, O., & Goldreich, D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00579 · Cited by 182
“The 2PD task is convenient to apply and is widely used to assess cutaneous innervation and central somatosensory function (Dellon, 1981; American Society for Surgery of the Hand, 1983; Van Boven and Johnson, 1994; Lundborg and Rosen, 2004; Jerosch-Herold, 2005; Campbell et al., 2013).”
Catley, M. J., Tabor, A., Wand, B. M., & Moseley, G. L. (2013) · Rheumatology · doi:10.1093/rheumatology/ket140 · Cited by 167
Autologous ear reconstruction for microtia does not result in loss of cutaneous sensitivity.
Denadai, R., Raposo-Amaral, C. E., Zanco, G. L., & Raposo- Amaral, C. A. (2019) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000005485 · Cited by 12
Threshold of tactile perception in a reconstructed auricle.
Öberg, M., Svensson, H., Becker, M., & Wikström, S.-O. (2011) · Journal of Plastic Surgery and Hand Surgery · doi:10.3109/2000656x.2010.542653 · Cited by 8
Metadata
- Authors
- JEROSCH-HEROLD, C.
- Venue
- Journal of Hand Surgery
- Publisher
- SAGE Publications
- Published
- 2005-06
- Volume
- 30
- Issue
- 3
- Pages
- 252-264
- ISSN
- 0266-7681 (ISSN-L)
- OpenAlex
- W2146270442
- Cited by
- 241
- References
- 27
- FWCI
- 0.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.