Photonic ring resonance is a versatile platform for performing multiplex immunoassays in real time
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Photonic ring resonance is a property of light where in certain circumstances specific wavelengths are trapped in a ring resonator. Sensors based on silicon photonic ring resonators function by detecting the interaction between light circulating inside the sensor and matter deposited on the sensor surface. Binding of biological material results in a localized change in refractive index on the sensor surface, which affects the circulating optical field extending beyond the sensor boundary. That is, the resonant wavelength will change when the refractive index of the medium around the ring resonator changes. Ring resonators can be fabricated onto small silicon chips, allowing development of a miniature multiplex array of ring based biosensors. This paper describes the properties of such a system when responding to the refractive index changed in a simple and precise way by changing the ionic strength of the surrounding media, and in a more useful way by the binding of macromolecules to the surface above the resonators. Specifically, a capture immunoassay is described that measures the change of resonant wavelength as a patient serum sample with anti-SS-A autoantibodies is flowed over a chip spotted with SS-A antigen and amplified with anti-IgG. The technology has been miniaturized and etched into a 4×6mm silicon chip that can measure 32 different reactions in quadruplicate simultaneously. The variability between 128 rings on a chip as measured by 2M salt assays averaged 0.6% CV. The output of the assays is the average shift per cluster of 4 rings, and the assays averaged 0.5% CV between clusters. The variability between chips averaged 1.8%. Running the same array on multiple instruments showed that after some improvements to the wavelength referencing system, the upper boundary of variation was 3% between 13 different instruments. The immunoassay displayed about 2% higher variability than the salt assays. There are several outstanding features of this system. The amount of antigen used on the chip for each test is around 200 picograms, only a few microliters of sample is necessary, and the assays take <10min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iqbal, M., Gleeson, M. A., Spaugh, B., Tybor, F., Gunn, W. G., Hochberg, M., Baehr-Jones, T., Bailey, R. C., & Gunn, L. C. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2032510 · Cited by 551
Self-citation
Cited by
IgA dominates the early neutralizing antibody response to SARS-CoV-2
Sterlin, D., Mathian, A., Miyara, M., Mohr, A., Anna, F., Claër, L., Quentric, P., Fadlallah, J., Devilliers, H., Ghillani, P., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abd2223 · Cited by 1,037
Self-citationIntegrating photonics with silicon nanoelectronics for the next generation of systems on a chip
Atabaki, A. H., Moazeni, S., Pavanello, F., Gevorgyan, H., Notaros, J., Alloatti, L., Wade, M. T., Sun, C., Kruger, S. A., Meng, H., et al. (2018) · Nature · doi:10.1038/s41586-018-0028-z · Cited by 927
Advances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Yang, W., Chen, J., Zhang, Y., Zhang, Y., He, J., & Fang, X. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808182 · Cited by 294
Heterogeneously Integrated InP\/Silicon Photonics: Fabricating Fully Functional Transceivers
Jones, R., Doussiere, P., Driscoll, J. B., Lin, W., Yu, H., Akulova, Y., Komljenovic, T., & Bowers, J. E. (2019) · IEEE Nanotechnology Magazine · doi:10.1109/mnano.2019.2891369 · Cited by 236
“commercialization, so far, has focused on optical communication (telecom [2] and data center [3]) and biosensing [4], with a wealth of future application areas, including high-performance computing [5], automotive (lidar) [6], optical switches [7], and artificial intelligence [8].”
Background
Metadata
- Authors
- Mudumba, S., de Alba, S., Romero, R., Cherwien, C., Wu, A., Wang, J., Gleeson, M. A., Iqbal, M., & Burlingame, R. W.
- Venue
- Journal of Immunological Methods
- Publisher
- Elsevier BV
- Published
- 2017-09
- Volume
- 448
- Pages
- 34-43
- ISSN
- 0022-1759 (ISSN-L)
- OpenAlex
- W2615728508
- Cited by
- 63
- References
- 1
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photonic ring resonance is a versatile platform for performing multiplex immunoassays in real time. https://app.cochat.ai/papers/10.1016/j.jim.2017.05.005
- The paper
- Mudumba, S., de Alba, S., Romero, R., Cherwien, C., Wu, A., Wang, J., Gleeson, M. A., Iqbal, M., & Burlingame, R. W. (2017). Photonic ring resonance is a versatile platform for performing multiplex immunoassays in real time. Journal of Immunological Methods. https://doi.org/10.1016/j.jim.2017.05.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.