Transversely isotropic tensile material properties of skeletal muscle tissue
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Of the plethora of work performed analyzing skeletal muscle tissue, relatively little has been done in the examination of its passive material properties. Previous studies of the passive properties of skeletal muscle have been primarily performed along the longitudinal material direction. In order to ensure the accuracy of the predictions of computational models of skeletal muscles, a better understanding of the tensile three-dimensional material properties of muscle tissue is necessary. To that end, the purpose of this study was to collect a comprehensive set of tensile stress-strain data from skeletal muscle tissue. Load-deformation data was collected from eighteen extensor digitorum longus muscles, dissected free of aponeuroses, from nine New Zealand White rabbits tested under longitudinal extension (LE), transverse extension (TE), or longitudinal shear (LS). The linear modulus, ultimate stress, and failure strain were calculated from stress-strain results. Results indicate that the linear modulus under LE is significantly higher than the modulus of either TE or LS. Additionally, the ultimate stress of muscle was seen to be significantly higher under LE than TE. Conversely, the failure strain was significantly higher under TE than under LE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P., & Goodier, J. N. (1934) · Virtual Defense Library (Ministerio de Defensa) · Cited by 13,717
The heat of shortening and the dynamic constants of muscle
Hill, A. V. (1938) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1938.0050 · Cited by 3,669
Mathur, A. B., Collinsworth, A. M., Reichert, W. M., Kraus, W. E., & Truskey, G. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00149-x · Cited by 589 · cited 2×
“Further, the only studies that have reported experimentally-determined transverse material properties have been under compression (Aimedieu et al., 2003; Mathur et al., 2001; Bosboom et al., 2001; Van Loocke et al., 2006).”
BackgroundThe heat of activation and the heat of shortening in a muscle twitch
Hill, A. V. (1949) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1949.0019 · Cited by 418
Three-Dimensional Representation of Complex Muscle Architectures and Geometries
Blemker, S. S., & Delp, S. L. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-1433-7 · Cited by 352 · cited 3×
“…(K.R. Kaufman). muscle model introduced in 1938 (Hill, 1938) to threedimensional continuum-basedmusclemodels that have been developed more recently (Blemker and Delp, 2005; Gielen et al., 2000; Jenkyn et al., 2002; Johansson et al., 2000; Martins et al., 1998; Odegard et al., in press; Yucesoy et…”
BackgroundInfluentialVan Loocke, M., Lyons, C. G., & Simms, C. K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.02.007 · Cited by 228 · cited 2×
“Comparisons with studies of skeletal muscle under compression (Van Loocke et al., 2006, 2008) suggest that skeletal muscle tissue is a bimodularmaterial.”
BackgroundActive length‐tension relation and the effect of muscle pinnation on fiber lengthening
Muhl, Z. F. (1982) · Journal of Morphology · doi:10.1002/jmor.1051730305 · Cited by 213 · cited 2×
“…et al., 1998; Hete and Shung, 1995; Lin et al., 1999; Linder-Ganz and Gefen, 2004; Davis et al., 2003; Gareis et al., 1992; Hawkins and Bey, 1997; Muhl, 1982; Van Loocke et al., 2006), many have used the load and displacement seen across the entire musculotendinous unit to derive stress and…”
BackgroundA numerical model of passive and active behavior of skeletal muscles
Martins, J. A. C., Pires, E. B., Salvado, R., & Dinis, P. B. (1998) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(97)00162-x · Cited by 212 · cited 1×
“…model introduced in 1938 (Hill, 1938) to threedimensional continuum-basedmusclemodels that have been developed more recently (Blemker and Delp, 2005; Gielen et al., 2000; Jenkyn et al., 2002; Johansson et al., 2000; Martins et al., 1998; Odegard et al., in press; Yucesoy et al., 2002).”
BackgroundLinder‐Ganz, E., & Gefen, A. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00888.2003 · Cited by 210 · cited 4×
“Likewise, the order of magnitude reduction seen in the transverse modulus of 22 kPa from the current study correlates with the reported value of 75 kPa reported by Linder-Ganz and Gefen (2004).”
BackgroundMethodResultInfluentialYücesoy, C. A., Koopman, H. F. J. M., Huijing, P. A., & Grootenboer, H. J. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00069-6 · Cited by 208 · cited 1×
“…model introduced in 1938 (Hill, 1938) to threedimensional continuum-basedmusclemodels that have been developed more recently (Blemker and Delp, 2005; Gielen et al., 2000; Jenkyn et al., 2002; Johansson et al., 2000; Martins et al., 1998; Odegard et al., in press; Yucesoy et al., 2002).”
Background
Cited by
Validation of shear wave elastography in skeletal muscle
Eby, S. F., Song, P., Chen, S., Chen, Q., Greenleaf, J. F., & An, K.-N. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.033 · Cited by 545
Ultrasound Elastography: The New Frontier in Direct Measurement of Muscle Stiffness
Brandenburg, J. E., Eby, S. F., Song, P., Zhao, H., Brault, J. S., Chen, S., & An, K.-N. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.07.007 · Cited by 327
Brown, M., Li, J., Moraes, C., Tabrizian, M., & Li-Jessen, N. Y. K. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121786 · Cited by 282
Conducting polymer-hydrogels for medical electrode applications
Green, R. A., Baek, S., Poole-Warren, L. A., & Martens, P. J. (2010) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/11/1/014107 · Cited by 268
Liu, T., Jiao, C., Peng, X., Chen, Y.-N., Chen, Y., He, C., Liu, R., & Wang, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb02556h · Cited by 248
Dielectric elastomer actuators
Hajiesmaili, E., & Clarke, D. R. (2021) · Journal of Applied Physics · doi:10.1063/5.0043959 · Cited by 229
A mathematical model of force transmission from intrafascicularly terminating muscle fibers
Sharafi, B., & Blemker, S. S. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.038 · Cited by 88
“87) (Morrow et al., 2010) 5 (Trotter and Purslow, 1992; Trotter et al.”
Influential
Metadata
- Authors
- Morrow, D. A., Haut Donahue, T. L., Odegard, G. M., & Kaufman, K. R.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 3
- Issue
- 1
- Pages
- 124-129
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2160606841
- Cited by
- 238
- References
- 24
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.