The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Mechanical characterisation of polyurethane elastomer for biomedical applications
Open accessAbstract
Mechanical testing and modelling of a material for biomedical applications have to be based on conditions representative of the application of interest. In this work, an ether-based polyurethane elastomer is used to build mock arteries. The aim is to study the behaviour of arteries under pulsatile loading conditions and how that behaviour changes with the development and progression of atherosclerosis. Polyurethane elastomers are widely used as biomaterials, e.g. in tube form for bypasses and catheters. However, their mechanical behaviour has not been extensively characterised. This work establishes the variations in the behaviour of polyurethane elastomer with temperature, humidity and strain rate and also reports planar and equibiaxial tension, relaxation, creep and cyclic test results, providing a comprehensive characterisation of the material. Test results are used to determine the properties of the polyurethane elastomer and in the selection of a representative material model for future simulations of arterial behaviour and the development of atherosclerosis. The results show that the behaviour of the elastomer is significantly dependent on both humidity and temperature, with Young's modulus of 7.4 MPa, 5.3 MPa and 4.7 MPa under dry-room temperature, wet-room temperature and wet at 37 ( composite function)C conditions, respectively. The elastomer also exhibits rate-dependent viscoelastic behaviour. Yeoh's hyperelastic material model provided the best fit to the entire range of experimental data. The Neo-Hookean model provides a good fit at small strain but significantly diverges at large strains. Nevertheless, in applications where deformations are relatively small, i.e. below 15%, the Neo-Hookean model can be used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318 · cited 2×
“This is adequately covered in literature (Stokes et al., 1995; Wiggins et al., 2003; Thoma, 1987; Schmidt et al., 1998; Zhao et al., 1990, 1991; Wu et al., 1992; Schubert et al., 1995, 1997).”
Background(2000) · doi:10.1201/9781482270365 · Cited by 282
Cited by
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Metadata
- Authors
- Kanyanta, V., & Ivankovic, A.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 3
- Issue
- 1
- Pages
- 51-62
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2001610571
- Cited by
- 179
- References
- 2
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical characterisation of polyurethane elastomer for biomedical applications. https://app.cochat.ai/papers/10.1016/j.jmbbm.2009.03.005
- The paper
- Kanyanta, V., & Ivankovic, A. (2010). Mechanical characterisation of polyurethane elastomer for biomedical applications. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2009.03.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.