Extracellular bone matrix exhibits hardening elastoplasticity and more than double cortical strength: Evidence from homogeneous compression of non-tapered single micron-sized pillars welded to a rigid substrate
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We here report an improved experimental technique for the determination of Young׳s modulus and uniaxial strength of extracellular bone matrix at the single micrometer scale, giving direct access to the (homogeneous) deformation (or strain) states of the tested samples and to the corresponding mechanically recoverable energy, called potential or elastic energy. Therefore, a new protocol for Focused Ion Beam milling of prismatic non-tapered micropillars, and attaching them to a rigid substrate, was developed. Uniaxial strength turns out as at least twice that measured macroscopically, and respective ultimate stresses are preceded by hardening elastoplastic states, already at very low load levels. The unloading portion of quasi-static load-displacement curves revealed Young׳s modulus of 29GPa in bovine extracellular bone matrix. This value is impressively confirmed by the corresponding prediction of a multiscale mechanics model for bone, which has been comprehensively validated at various other observation scales, across tissues from the entire vertebrate animal kingdom.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The conflicts between strength and toughness
Ritchie, R. O. (2011) · Nature Materials · doi:10.1038/nmat3115 · Cited by 3,989
Materials become insensitive to flaws at nanoscale: Lessons from nature
Gao, H., Ji, B., Jäger, I. L., Arzt, E., & Fratzl, P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0631609100 · Cited by 1,922
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Schwiedrzik, J., Raghavan, R., Bürki, A., LeNader, V., Wolfram, U., Michler, J., & Zysset, P. (2014) · Nature Materials · doi:10.1038/nmat3959 · Cited by 182
Anisotropic yield behavior of bone under combined axial force and torque
Cezayirlioglu, H., Bahniuk, E., Davy, D. T., & Heiple, K. G. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90045-4 · Cited by 164
Non-destructive characterization of microdamage in cortical bone using low field pulsed NMR
Nicolella, D. P., Ni, Q., & Chan, K. S. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.007 · Cited by 25
Cited by
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
“However, the chosen correla-681 tions are a natural choice since it was shown that the ECM behaves in a plastic682 fashion (Schwiedrzik et al., 2014; Luczynski et al., 2015) and the variables should683 correlate unless the microstructure dominates the response.”
BackgroundShah, F. A., Ruscsák, K., & Palmquist, A. (2019) · Bone Research · doi:10.1038/s41413-019-0053-z · Cited by 115
Levrero-Florencio, F., Margetts, L., Sales, E., Xie, S., Manda, K., & Pankaj, P. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.04.008 · Cited by 46
“However, previous experimental and theoretical studies such as Schwiedrzik et al. (2014), Luczynski et al. (2015) and Fritsch et al. (2009) showed that the extracellular matrix of bone has a hardening behaviour after yield.”
Microscopic assessment of bone toughness using scratch tests
Kataruka, A., Mendu, K., Okeoghene, O., Puthuvelil, J., & Akono, A.-T. (2017) · Bone Reports · doi:10.1016/j.bonr.2016.12.001 · Cited by 28
Metadata
- Authors
- Luczynski, K. W., Steiger-Thirsfeld, A., Bernardi, J., Eberhardsteiner, J., & Hellmich, C.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 52
- Pages
- 51-62
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2085053537
- Cited by
- 70
- References
- 7
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extracellular bone matrix exhibits hardening elastoplasticity and more than double cortical strength: Evidence from homogeneous compression of non-tapered single micron-sized pillars welded to a rigid substrate. https://app.cochat.ai/papers/10.1016/j.jmbbm.2015.03.001
- The paper
- Luczynski, K. W., Steiger-Thirsfeld, A., Bernardi, J., Eberhardsteiner, J., & Hellmich, C. (2015). Extracellular bone matrix exhibits hardening elastoplasticity and more than double cortical strength: Evidence from homogeneous compression of non-tapered single micron-sized pillars welded to a rigid substrate. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2015.03.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.