Evaluation of transcatheter heart valve biomaterials: Biomechanical characterization of bovine and porcine pericardium
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objective Bovine pericardium (BP) has been identified as a choice biomaterial for the development of surgical bioprosthetic heart valves (BHV) and transcatheter aortic valves (TAV). Porcine pericardium (PP) and younger BP have been suggested as candidates TAV leaflet biomaterials for smaller-profile devices due to their reduced thickness; however, their mechanical and structural properties remain to be fully characterized. This study characterized the material properties of chemically treated thick (PPK) and thin (PPN) PP, as well as fetal (FBP), calf (CBP) and adult (ABP) BP tissues in order to better understand their mechanical behavior. Methods Planar biaxial testing and uniaxial failure testing methods were employed to quantify tissue mechanical responses and failure properties. Fiber characteristics were examined using histological analysis. Results ABP and CBP tissues were significantly stiffer and stronger than the younger FBP tissues. Histological analysis revealed a significantly larger concentration of thin immature collagen fibers in the FBP tissues than in the ABP and CBP tissues. While PP tissues were thinnest, they were stiffer and less extensible than the BP tissues. Conclusions Due to comparable mechanical properties but significantly reduced thickness, CBP tissue may be a more suitable material for TAV manufacturing than ABP tissue. FBP tissue, despite its reduced thickness and higher flexibility, was weaker and should be studied in more detail. Although PP tissues are the thinnest, they were least extensible and failed at earlier strain than BP tissues. The differences between PP and BP tissues should be further investigated and suggest that they should not be used interchangeably in the manufacturing of TAV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739 · cited 1×
“A decade later after the first proof-of-concept TAVR case performed [6], with >200,000 procedures having been performed in >65 countries, 5-year valve durability findings [7, 8] with smaller experience reported up to 9 years show no significant signal of structural TAV deterioration.”
BackgroundKapadia, S. R., Leon, M. B., Makkar, R. R., Tuzcu, E. M., Svensson, L. G., Kodali, S., Webb, J. G., Mack, M. J., Douglas, P. S., Thourani, V. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60290-2 · Cited by 867 · cited 1×
“A decade later after the first proof-of-concept TAVR case performed [6], with >200,000 procedures having been performed in >65 countries, 5-year valve durability findings [7, 8] with smaller experience reported up to 9 years show no significant signal of structural TAV deterioration.”
BackgroundInjury and repair of the musculoskeletal soft tissues. Savannah, Georgia, June 18–20, 1987
Woo, S. L., & Buckwalter, J. A. (1988) · Journal of Orthopaedic Research · doi:10.1002/jor.1100060615 · Cited by 141
Vinci, M. C., Tessitore, G., Castiglioni, L., Prandi, F., Soncini, M., Santoro, R., Consolo, F., Colazzo, F., Micheli, B., Sironi, L., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064769 · Cited by 42 · cited 2×
“(2013) [58] investigated the mechanical properties of decellularized cryopreserved human pericardium.”
Background
Cited by
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Mammalian Pericardium‐Based Bioprosthetic Materials in Xenotransplantation and Tissue Engineering
Grebenik, E. A., Gafarova, E. R., Istranov, L. P., Istranova, E. V., Ma, X., Xu, J., Guo, W., Atala, A., & Timashev, P. S. (2020) · Biotechnology Journal · doi:10.1002/biot.201900334 · Cited by 30
Walker, S., Dittfeld, C., Jakob, A., Schönfelder, J., König, U., & Tugtekin, S.-M. (2022) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0040-1705100 · Cited by 11
Metadata
- Authors
- Caballero, A., Sulejmani, F., Martin, C., Pham, T., & Sun, W.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2017-11
- Volume
- 75
- Pages
- 486-494
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2744932596
- Cited by
- 110
- References
- 4
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of transcatheter heart valve biomaterials: Biomechanical characterization of bovine and porcine pericardium. https://app.cochat.ai/papers/10.1016/j.jmbbm.2017.08.013
- The paper
- Caballero, A., Sulejmani, F., Martin, C., Pham, T., & Sun, W. (2017). Evaluation of transcatheter heart valve biomaterials: Biomechanical characterization of bovine and porcine pericardium. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2017.08.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.