The DOI matches its Crossref record.
Indirectly extruded biodegradable Zn-0.05wt%Mg alloy with improved strength and ductility: In vitro and in vivo studies
Abstract
Abstract As compared to permanent orthopedic implants for load-bearing applications, biodegradable orthopedic implants have the advantage of no need for removing after healing, but they suffer from the “trilemma” problem of compromising among sufficiently high mechanical properties, good biocompatibility and proper degradation rate conforming to the growth rate of new bones. In the present work, in vitro and in vivo studies of a Zn-0.05wt%Mg alloy (namely, Zn-0.05Mg alloy) were conducted with pure Zn as a control. The Zn-0.05Mg alloy is composed of a small amount of Mg2Zn11 phase embedded in the refined Zn matrix with an average grain size of ∼20 μm. The addition of 0.05 wt% Mg into Zn significantly increases the ultimate tensile strength up to 225 MPa and the elongation to fracture to 26%, but has little influence on the in vitro degradation rate. Both Zn and Zn-0.05Mg alloy exhibit homogeneous in vitro degradation with a rate of about 0.15 mm/year. Based on the cytotoxicity evaluation, Zn and Zn-0.05Mg alloy do not induce toxicity to L-929 cells, indicating that they have little toxicity to the general functions of the animal. An in vivo biocompatibility study of Zn and Zn-0.05Mg alloy samples by placing them in a rabbit model for 4, 12 and 24 weeks, respectively did not show any inflammatory cells, and demonstrated that new bone tissue formed at the bone/implant interface, suggesting that Zn and Zn-0.05Mg alloy promote the formation of new bone tissue. The in vivo degradation of Zn and Zn-0.05Mg alloy does not bring harm to the important organs and their cell structures. More interestingly, Zn and Zn-0.05Mg alloy exhibit strong antibacterial activity against Escherichia coli and Staphylococcus aureus. The above results clearly demonstrate that the Zn-0.05Mg alloy could be a potential biodegradable orthopedic implant material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alloying design of biodegradable zinc as promising bone implants for load-bearing applications
Yang, H., Jia, B., Zhang, Z., Qu, X., Li, G., Lin, W., Zhu, D., Dai, K., & Zheng, Y. (2020) · Nature Communications · doi:10.1038/s41467-019-14153-7 · Cited by 756
Antibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Self-citationKabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Current status and perspectives of zinc-based absorbable alloys for biomedical applications
Hernández-Escobar, D., Champagne, S., Yilmazer, H., Dikici, B., Boehlert, C. J., & Hermawan, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.034 · Cited by 309
Additive manufacturing of biodegradable metals: Current research status and future perspectives
Qin, Y., Wen, P., Guo, H., Xia, D., Zheng, Y., Jauer, L., Poprawe, R., Voshage, M., & Schleifenbaum, J. H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.046 · Cited by 303
Metadata
- Authors
- Xiao, C., Wang, L., Ren, Y., Sun, S., Zhang, E., Yan, C., Liu, Q., Sun, X., Shou, F., Duan, J., Wang, H., & Qin, G.
- Venue
- Journal of Materials Science & Technology
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 34
- Issue
- 9
- Pages
- 1618-1627
- ISSN
- 1005-0302 (ISSN-L)
- OpenAlex
- W2783171624
- Cited by
- 204
- References
- 0
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indirectly extruded biodegradable Zn-0.05wt%Mg alloy with improved strength and ductility: In vitro and in vivo studies. https://app.cochat.ai/papers/10.1016/j.jmst.2018.01.006
- The paper
- Xiao, C., Wang, L., Ren, Y., Sun, S., Zhang, E., Yan, C., Liu, Q., Sun, X., Shou, F., Duan, J., Wang, H., & Qin, G. (2018). Indirectly extruded biodegradable Zn-0.05wt%Mg alloy with improved strength and ductility: In vitro and in vivo studies. Journal of Materials Science & Technology. https://doi.org/10.1016/j.jmst.2018.01.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.