The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
SnO-SnO2 modified two-dimensional MXene Ti3C2T for acetone gas sensor working at room temperature
Abstract
Abstract Acetone, as widely used reagents in industry and laboratories, are extremely harmful to the human. So the detection of acetone gas concentrations and leaks in special environments at room temperature is essential. Herein, the nanocomposite combining SnO-SnO2 (p-n junction) and Ti3C2Tx MXene was successfully synthesized by a one-step hydrothermal method. Because of the existence of a small amount of oxygen during the hydrothermal conditions, part of the p-type SnO was oxidized to n-type SnO2, forming in-situ p-n junctions on the surface of SnO. The hamburger-like SnO-SnO2/Ti3C2Tx sensor exhibited improved acetone gas sensing response of 12.1 (Rg/Ra) at room temperature, which were nearly 11 and 4 times higher than those of pristine Ti3C2Tx and pristine SnO-SnO2, respectively. Moreover, it expressed a short recovery time (9 s) and outstanding reproducibility. Because of the different work functions, the Schottky barrier was formed between the SnO and the Ti3C2Tx nanosheets, acting as a hole accumulation layer (HALs) between Ti3C2Tx and tin oxides. Herein, the sensing mechanism based on the formation of hetero-junctions and high conductivity of the metallic phase of Ti3C2Tx MXene in SnO-SnO2/Ti3C2Tx sensors was discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sing, K. S. W. (1985) · Pure and Applied Chemistry · doi:10.1351/pac198557040603 · Cited by 24,485
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Room Temperature Gas Sensing of Two-Dimensional Titanium Carbide (MXene)
Lee, E., VahidMohammadi, A., Prorok, B. C., Yoon, Y. S., Beidaghi, M., & Kim, D.-J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11055 · Cited by 878
Design of highly porous SnO2-CuO nanotubes for enhancing H2S gas sensor performance
Park, K.-R., Cho, H.-B., Lee, J., Song, Y., Kim, W.-B., & Choa, Y.-H. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127179 · Cited by 260
Cited by
Flexible MXene/rGO/CuO hybrid aerogels for high performance acetone sensing at room temperature
Liu, M., Wang, Z., Song, P., Yang, Z., & Wang, Q. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129946 · Cited by 222
Self-citation
Metadata
- Authors
- Wang, Z., Wang, F., Hermawan, A., Asakura, Y., Hasegawa, T., Kumagai, H., Kato, H., Kakihana, M., Zhu, J., & Yin, S.
- Venue
- Journal of Materials Science & Technology
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 73
- Pages
- 128-138
- ISSN
- 1005-0302 (ISSN-L)
- OpenAlex
- W3089378988
- Cited by
- 216
- References
- 4
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SnO-SnO2 modified two-dimensional MXene Ti3C2T for acetone gas sensor working at room temperature. https://app.cochat.ai/papers/10.1016/j.jmst.2020.07.040
- The paper
- Wang, Z., Wang, F., Hermawan, A., Asakura, Y., Hasegawa, T., Kumagai, H., Kato, H., Kakihana, M., Zhu, J., & Yin, S. (2021). SnO-SnO2 modified two-dimensional MXene Ti3C2T for acetone gas sensor working at room temperature. Journal of Materials Science & Technology. https://doi.org/10.1016/j.jmst.2020.07.040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.