The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A method for positioning electrodes during surface EMG recordings in lower limb muscles
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lower limb skeletal muscle function after 6 wk of bed rest
Berg, H. E., Larsson, L., & Tesch, P. A. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.182 · Cited by 352
Geometrical factors in surface EMG of the vastus medialis and lateralis muscles
Rainoldi, A., Nazzaro, M., Merletti, R., Farina, D., Caruso, I., & Gaudenti, S. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00024-9 · Cited by 192 · cited 3×
“…spectrum are estimated from each single differential signal of a linear electrode array, whereas correlation coefficient (CC) and muscle fiber conduction velocity (CV) are estimated from a pair of double differential (DD) signals as described in Merletti et al. (1990) and Rainoldi et al. (2000).”
BackgroundMethodSelf-citation
Cited by
Gluteal Muscle Activation During Common Therapeutic Exercises
Distefano, L. J., Blackburn, J. T., Marshall, S. W., & Padua, D. A. (2009) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2009.2796 · Cited by 375
Human capacity for explosive force production: Neural and contractile determinants
Folland, J. P., Buckthorpe, M. W., & Hannah, R. (2014) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12131 · Cited by 327
Samuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
Muscle fatigue induced by two different resistances: Elastic tubing versus weight machines
Melchiorri, G., & Rainoldi, A. (2011) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.07.015 · Cited by 82
Self-citationLeveraging High-Density EMG to Investigate Bipolar Electrode Placement for Gait Prediction Models
Hodossy, B. K., Guez, A. S., Jing, S., Huo, W., Vaidyanathan, R., & Farina, D. (2024) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2024.3371099 · Cited by 10
Metadata
- Authors
- Rainoldi, A., Melchiorri, G., & Caruso, I.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 37-43
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2023890362
- Cited by
- 610
- References
- 2
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method for positioning electrodes during surface EMG recordings in lower limb muscles. https://app.cochat.ai/papers/10.1016/j.jneumeth.2003.10.014
- The paper
- Rainoldi, A., Melchiorri, G., & Caruso, I. (2004). A method for positioning electrodes during surface EMG recordings in lower limb muscles. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2003.10.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.