Characterization of flexible ECoG electrode arrays for chronic recording in awake rats
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We developed a 64 channel flexible polyimide ECoG electrode array and characterized its performance for long term implantation, chronic cortical recording and high resolution mapping of surface evoked potentials in awake rats. To achieve the longest possible recording periods, the flexibility of the electrode array, adhesion between the metals and carrier substrate, and biocompatibility was critical for maintaining the signal integrity. Experimental testing of thin film adhesion was applied to a gold – polyimide system in order to characterize relative interfacial fracture energies for several different adhesion layers, yielding an increase in overall device reliability. We tested several different adhesion techniques including: gold alone without an adhesion layer, titanium-tungsten, tantalum and chromium. We found the titanium-tungsten to be a suitable adhesion layer considering the biocompatibility requirements as well as stability and delamination resistance. While chromium and tantalum produced stronger gold adhesion, concerns over biocompatibility of these materials require further testing. We implanted the polyimide ECoG electrode arrays through a slit made in the skull of rats and recorded cortical surface evoked responses. The arrays performed reliably over a period of at least 100 days and signals compared well with traditional screw electrodes, with better high frequency response characteristics. Since the ultimate goal of chronically implanted electrode arrays is for neural prosthetic devices that need to last many decades, other adhesion layers that would prove safe for implantation may be tested in the same way in order to improve the device reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
The structural organization of layer IV in the somatosensory region (S I) of mouse cerebral cortex
Woolsey, T. A., & Van der Loos, H. (1970) · Brain Research · doi:10.1016/0006-8993(70)90079-x · Cited by 2,254
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 3×
“Under certain conditions, chromium may be a suitable adhesion layer for implantable electrodes (Mailley et al., 2004; Soden et al., 2004), and some chromium alloys may be non-toxic (Merrill et al., 2005), but these results require further testing.”
BackgroundResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“A comprehensive review on penetrating electrode implantation issues is given by Polikov et al. (2005).”
BackgroundIntracellular Correlates of Fast (>200 Hz) Electrical Oscillations in Rat Somatosensory Cortex
Jones, M. S., MacDonald, K. D., Choi, B., Dudek, F. E., & Barth, D. S. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.3.1505 · Cited by 184
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93
Flexible miniature ribbon cables for long‐term connection to implantable sensors
Hetke, J. F., Najafi, K., & Wise, K. D. (1990) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(90)87076-u · Cited by 33 · cited 1×
“Some polyimides have shown relatively large water absorption, swelling by 2% (Hetke et al., 1990), causing metal–polymer interface strain.”
Background
Cited by
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K., Donoghue, J. P., Fraser, S. E., Lippincott-Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 356
Silicon electronics on silk as a path to bioresorbable, implantable devices
Kim, D.-H., Kim, Y.-S., Amsden, J., Panilaitis, B., Kaplan, D. L., Omenetto, F. G., Zakin, M. R., & Rogers, J. A. (2009) · Applied Physics Letters · doi:10.1063/1.3238552 · Cited by 295
Organic electronics for high-resolution electrocorticography of the human brain
Khodagholy, D., Gelinas, J. N., Zhao, Z., Yeh, M., Long, M., Greenlee, J. D., Doyle, W., Devinsky, O., & Buzsáki, G. (2016) · Science Advances · doi:10.1126/sciadv.1601027 · Cited by 184
“Although polyimide-based arrays can be thin (20 to 30 mm), they are not conformable, and polyimide is not yet recognized as a biocompatible substrate for human use (17, 30, 31).”
BackgroundImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Metadata
- Authors
- Yeager, J. D., Phillips, D. J., Rector, D. M., & Bahr, D. F.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2008-08
- Volume
- 173
- Issue
- 2
- Pages
- 279-285
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2023047695
- Cited by
- 109
- References
- 7
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.