Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Abstract
We describe new manufacturing techniques and physical properties of an improved polymer-based longitudinal intrafascicular electrode (polyLIFE). Modifications were made to correct: (1) poor metal film adhesion and fatigue resistance, (2) inconsistent insulation adhesion and control over recording/stimulation zone length, and (3) insufficient tensile strength for clinical use. Metal adhesion was significantly improved by both plasma treatment and fiber rotation (about the long axis) during metal deposition. Fatigue resistance was improved by reduction in sputtering energy (time x power) combined with long axis rotation, resulting in thin metal films that were 250 times more resistant to cyclic bending fatigue. Insulation adhesion was enhanced with the application of an adhesion-promoting silicone (MED2-4013, Nusil), while the recording/stimulation zone length was controlled to 1 +/- 0.2mm (mean +/- S.D.). The polyLIFE was made more robust by the inclusion of three individually metallized fibers, improving its tensile strength by a factor of 4 while producing minimal changes to its overall stiffness. However, the metallized fiber redundancy did not significantly affect fatigue resistance. The manufacturing changes described in this study enable the construction of more mechanically robust polyLIFEs, which should provide greater success when chronically implanted in peripheral nerves.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
When higher selectivity is required, interfaces tend to be more invasive.
“When higher selectivity is required, interfaces tend to be more invasive.”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Lawrence et al. 2003
Cites
The Mathematical Theory of Equilibrium Cracks in Brittle Fracture
Barenblatt, G. I. (1962) · Advances in applied mechanics · doi:10.1016/s0065-2156(08)70121-2 · Cited by 5,321 · see citing works
Suresh, S. (1998) · Cambridge University Press eBooks · doi:10.1017/cbo9780511806575 · Cited by 4,553 · see citing works
Silicon as a mechanical material
Petersen, K. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,925 · see citing works
Mechanical properties of thin films
Nix, W. D. (1989) · Metallurgical Transactions A · doi:10.1007/bf02666659 · Cited by 2,551 · see citing works
Physical properties of polymers handbook
Mark, J. (2007) · Springer eBooks · doi:10.1007/978-0-387-69002-5 · Cited by 1,670 · see citing works
Roy, R., Leamy, H. J., White, C. W., Kaufmann, E. N., Schwoebel, R. L., Taylor, K. C., & Northrup, C. J. M. (1984) · Physics Today · doi:10.1063/1.2916117 · Cited by 1,012 · see citing works
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644 · see citing works
Materials science of thin films : deposition and structure
Ohring, M. (2002) · Cited by 583 · see citing works
Lee, L.-H. (1991) · Springer eBooks · doi:10.1007/978-1-4899-2073-7 · Cited by 536 · see citing works
Bressers, J. (1987) · Springer eBooks · doi:10.1007/978-94-009-1347-9_39 · Cited by 453 · see citing works
Xi. The origin of fatigue fracture in copper
Thompson, N., Wadsworth, N. J., & Louat, N. (1956) · Philosophical magazine · doi:10.1080/14786435608238086 · Cited by 438 · see citing works
Grain boundary ductile fracture in precipitation hardened aluminum alloys
Vasudevan, A. K., & Doherty, R. D. (1987) · Acta Metallurgica · doi:10.1016/0001-6160(87)90001-0 · Cited by 372 · see citing works
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 358 · see citing works
A methodology for determining mechanical properties of freestanding thin films and MEMS materials
Espinosa, H. D., Prorok, B. C., & Fischer, M. (2002) · Journal of the Mechanics and Physics of Solids · doi:10.1016/s0022-5096(02)00062-5 · Cited by 337 · see citing works
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · see citing works
The yield stress of polycrystalline thin films
Thompson, C. V. (1993) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.1993.0237 · Cited by 220 · see citing works
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · see citing works
Size effects on the mechanical behavior of gold thin films
Espinosa, H. D., & Prorok, B. C. (2003) · Journal of Materials Science · doi:10.1023/a:1026321404286 · Cited by 178 · see citing works
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · see citing works
Histopathological evaluation of materials implanted in the cerebral cortex
Stensaas, S. S., & Stensaas, L. J. (1978) · Acta Neuropathologica · doi:10.1007/bf00689766 · Cited by 177 · see citing works
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174 · see citing works
Plasma Etching Fundamentals and Applications
Sugawara, M., Stansficld, B. L., Handa, S., et al. (1998) · doi:10.1093/oso/9780198562870.001.0001 · Cited by 173 · see citing works
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172 · see citing works
Self-citationMetal polyimide interface: A titanium reaction mechanism
Ohuchi, F. S., & Freilich, S. C. (1986) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.573450 · Cited by 170 · see citing works
Regeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 164 · cited 1× · see citing works
“been developed including silicon-based (Akin et al., 1994; Branner et al., 2001; Edell, 1986; Kovacs et al., 1992; Rutten et al., 1991; Veltink et al., 1989) and polyimide-based (González and Rodrı́guez, 1997; Stieglitz and Meyer, 1997) microelectrode arrays as well as longitudinally implanted microwires (Bowman and E…”
MethodScaling limitations of silicon multichannel recording probes
Najafi, K., Ji, J., & Wise, K. D. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43605 · Cited by 163 · see citing works
Stress-Induced Phenomena In Metallization
Ho, P. S., Baker, S. P., Nakamura, T., et al. (1994) · Cited by 159 · see citing works
Strength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146 · see citing works
A micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144 · see citing works
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · see citing works
Ohring, M. (2002) · Elsevier eBooks · doi:10.1016/b978-012524975-1/50012-4 · Cited by 136 · see citing works
Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76386 · Cited by 129 · see citing works
A flexible perforated microelectrode array for extended neural recordings
Boppart, S. A., Wheeler, B. C., & Wallace, C. S. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.108125 · Cited by 126 · see citing works
Stieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125 · see citing works
Low amplitude fatigue of copper single crystals—I. The role of the surface in fatigue failure
Basinski, Z. S., Pascual, R., & Basinski, S. J. (1983) · Acta Metallurgica · doi:10.1016/0001-6160(83)90049-4 · Cited by 122 · see citing works
A two-dimensional molecular dynamics simulation of thin film growth by oblique deposition
Dong, L., Smith, R. W., & Srolovitz, D. J. (1996) · Journal of Applied Physics · doi:10.1063/1.363621 · Cited by 108 · see citing works
An intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107 · see citing works
Self-citationWood, W. A. (1958) · Philosophical magazine · doi:10.1080/14786435808237004 · Cited by 107 · see citing works
Materials and Processes for Surface and Interface Engineering
Pauleau, Y. (1995) · Springer eBooks · doi:10.1007/978-94-011-0077-9 · Cited by 102 · see citing works
Grain structure variation with temperature for evaporated metal films
Hentzell, H. T. G., Grovenor, C. R. M., & Smith, D. A. (1984) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.572727 · Cited by 83 · see citing works
Metallized polymer fibers as leadwires and intrafascicular microelectrodes
McNaughton, T. G., & Horch, K. W. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00111-2 · Cited by 76 · see citing works
Self-citationBowman, B. R., & Erickson, R. C. (1985) · Annals of Biomedical Engineering · doi:10.1007/bf02371251 · Cited by 66 · see citing works
González, C., & Rodrı́guez, M. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)02202-9 · Cited by 63 · see citing works
Multielectrode intrafascicular and extraneural stimulation
Veltink, P. H., van Alsté, J. A., & Boom, H. B. K. (1989) · Medical and Biological Engineering and Computing · doi:10.1007/bf02442165 · Cited by 62 · see citing works
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55 · see citing works
Self-citationMaissel, L. I., & FRANCOMBE, M. H. (1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 54 · see citing works
Grain boundary self-diffusion in evaporated Au films at low temperatures
Gupta, D., & Asai, K. W. (1974) · Thin Solid Films · doi:10.1016/0040-6090(74)90285-5 · Cited by 51 · see citing works
Malmstrom, J. A., McNaughton, T. G., & Horch, K. W. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.35 · Cited by 50 · cited 1× · see citing works
“, 2002) and dorsal rootlets (Malmstrom et al., 1998), but have yet to achieve the reliability required for chronic recording.”
BackgroundSelf-citationSheu, G. S., & Shyu, S. S. (1994) · Journal of Adhesion Science and Technology · doi:10.1163/156856194x00906 · Cited by 50 · see citing works
Development of the thin-film longitudinal intra-fascicular electrode
Yoshida, K., Pellinen, D. S., Pivin, D. P., Rousche, P. J., & Kipke, D. R. (2000) · Cited by 44 · see citing works
Multielectrode spiral cuff for ordered and reversed activation of nerve fibres
Rozman, J., Sovinec, B., Trlep, M., & Zorko, B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90039-2 · Cited by 41 · see citing works
Action potential classification with dual channel intrafascicular electrodes
McNaughton, T. G., & Horch, K. W. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.301727 · Cited by 41 · see citing works
Self-citationPolyaniline spinning solutions and fibers
Hsu, C.-C., Cohen, J. D., & Tietz, R. F. (1993) · Synthetic Metals · doi:10.1016/0379-6779(93)91155-u · Cited by 40 · see citing works
Microtechnical Interfaces to Neurons
Stieglitz, T., & Meyer, J.-U. (1998) · Topics in current chemistry · doi:10.1007/3-540-69544-3_6 · Cited by 35 · see citing works
Moulton, J., & Smith, P. (1992) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.1992.090300809 · Cited by 31 · see citing works
Ion bombardment and titanium film growth on polyimide
Bodö, P., & Sundgren, J. ‐. (1988) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.575562 · Cited by 31 · see citing works
Surface modification of Kevlar 149 fibers by gas plasma treatment
Sheu, G. S., & Shyu, S. S. (1994) · Journal of Adhesion Science and Technology · doi:10.1163/156856194x00212 · Cited by 27 · see citing works
Interface Design for Thin Film Adhesion
Baglin, J. E. E. (1991) · Springer eBooks · doi:10.1007/978-1-4899-2073-7_13 · Cited by 19 · see citing works
Plasma etching : fundamentals and applications
菅原, 実., & Stansfield, B. L. (1998) · Oxford University Press eBooks · Cited by 18 · see citing works
Improvement of adhesion of Kevlar fiber to epoxy by chemical modification
Shed, G. S., Lin, T., Shyu, S. S., et al. (1994) · Journal of Adhesion Science and Technology · doi:10.1163/156856194x00203 · Cited by 18 · see citing works
Walter, J. S., Griffith, P., Sweeney, J., Scarpine, V., Bidnar, M., McLane, J. A., & Robinson, C. J. (1997) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.1997.11719475 · Cited by 18 · see citing works
Interface Structure, Adhesion, and Ion Beam Processing
Baglin, J. E. E. (1995) · Springer eBooks · doi:10.1007/978-94-011-0077-9_4 · Cited by 14 · see citing works
Nucleation, growth, interdiffusion, and adhesion of metal films on polymers
Faupel, F., Thran, A., Zaporojtchenko, V., et al. (1999) · AIP conference proceedings · doi:10.1063/1.59909 · Cited by 10 · see citing works
Environmental Effects on General Fatigue Resistance and Crack Nucleation in Metals and Alloys.
Duquette, D. J. (1978) · Defense Technical Information Center (DTIC) · Cited by 10 · see citing works
Plasma Treatment of Polymers for Improving Al Adhesion
Lamendola, R., Matarrese, E., Creatore, M., et al. (1998) · MRS Proceedings · doi:10.1557/proc-544-269 · Cited by 6 · see citing works
Tem Study of Yielding in Polycrystalline Gold Thin Films
Owusu-Boahen, K., & King, A. H. (1997) · MRS Proceedings · doi:10.1557/proc-505-383 · Cited by 4 · see citing works
Plasma-assisted physical vapour deposition
Fancey, K. S., & Matthews, A. (1991) · Springer eBooks · doi:10.1007/978-94-011-3040-0_6 · Cited by 4 · see citing works
Conductive polymer-high modulus polymer alloys. A solution route to Kevlar-polypyrrole hybrid fibers
Nemoto, H., Marks, T. J., Groot, D. C. D., et al. (1991) · Synthetic Metals · doi:10.1016/0379-6779(91)91096-s · Cited by 3 · see citing works
Stuart, R. V. (1983) · Elsevier eBooks · doi:10.1016/b978-0-12-674780-5.50007-x · Cited by 3 · see citing works
Thermal history of substrates during sputtering and sputter etching
(1980) · Microelectronics Reliability · doi:10.1016/0026-2714(80)90507-7 · Cited by 3 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573 · see citing works
Self-citationHassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501 · see citing works
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · see citing works
Sensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308 · see citing works
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231 · see citing works
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · see citing works
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186 · see citing works
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183 · see citing works
Self-citationImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
Aszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61776-1 · Cited by 152 · see citing works
Wark, H. A. C., Sharma, R., Mathews, K. S., Fernandez, E., Yoo, J., Christensen, B., Tresco, P., Rieth, L., Solzbacher, F., Normann, R. A., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045003 · Cited by 148 · see citing works
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120 · see citing works
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · see citing works
Self-citationBadia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103 · see citing works
Innovations in Prosthetic Interfaces for the Upper Extremity
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a97e5f · Cited by 71 · see citing works
Jia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70 · see citing works
A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56 · see citing works
Giagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58 · see citing works
Regenerated sciatic nerve axons stimulated through a chronically implanted macro-sieve electrode
MacEwan, M. R., Zellmer, E. R., Wheeler, J. J., Burton, H., & Moran, D. W. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00557 · Cited by 48 · see citing works
Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
Restaino, S. M., Abliz, E., Wachrathit, K., Krauthamer, V., & Shah, S. B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-73 · Cited by 44 · see citing works
Wang, J., Thow, X. Y., Wang, H., Lee, S., Voges, K., Thakor, N. V., Yen, S., & Lee, C. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700987 · Cited by 43 · see citing works
Navarro, X., Lago, N., Vivo, M., Yoshida, K., Koch, K. P., Poppendieck, W., & Micera, S. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428492 · Cited by 36 · see citing works
Pena, A. E., Kuntaegowdanahalli, S. S., Abbas, J. J., Patrick, J., Horch, K. W., & Jung, R. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa814d · Cited by 22 · see citing works
Self-citationIncreased selectivity of clinical peripheral nerve interfaces
Tyler, D. J., Peterson, E. J., Brill, N., & White, K. (2011) · 2011 5th International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910536 · Cited by 10 · see citing works
Wu, Y., & Guo, L. (2020) · Neural Interface Engineering · doi:10.1007/978-3-030-41854-0_5 · Cited by 3 · see citing works
- Authors
- Lawrence, S. M., Dhillon, G. S., & Horch, K. W.
- Affiliations
- University of Utah (US)
- Corresponding author
- Horch, Kenneth W
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2003-12
- Volume
- 131
- Issue
- 1-2
- Pages
- 9-26
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2046003207
- Semantic Scholar
- 826c76f761fa8f7a27250a5989d8ded173c1d7f8
- Cited by
- 93
- References
- 70
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 7 · 2019: 2 · 2018: 6 · 2017: 6 · 2016: 3 · 2015: 4 · 2014: 5 · 2013: 4 · 2012: 2
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- intrafascicular electrodes, peripheral nerve stimulation, chronic implantation, fatigue resistance, plasma treatment, silicone insulation, tensile strength, electrode fabrication
- MeSH terms
- Tissue Adhesions, Electrodes, Implanted, Gold, Materials Testing, Microelectrodes, Microscopy, Electron, Scanning, Peripheral Nerves, Platinum, Polymers, Surface Properties, Temperature, Time Factors, Titanium, Electric Impedance, Prostheses and Implants, Coated Materials, Biocompatible, Tissue Engineering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review