Comparison of the brain penetration injury associated with microdialysis and voltammetry
Open accessAbstract
Emerging evidence suggests that differences between microdialysis- and voltammetry-based estimates of extracellular dopamine in the brain might originate in the different penetration injury associated with each technique. To address this issue in a direct fashion, microdialysis probes and voltammetric microelectrodes were implanted in the rat striatum for 1, 4, or 24 h. Tissues were perfused with a suspension of fluorescently labeled nanobeads to assess blood vessels near the implant. Tissue sections (30 microm) were labeled with antibodies for PECAM, an endothelial cell marker, or GFAP, a glial marker. In non-implanted control tissue, blood vessels were reliably double-labeled with nanobeads and antiPECAM. Tissue near microdialysis probe tracks exhibited ischemia in the form of PECAM immunoreactive blood vessels devoid of nanobeads. Ischemia was most apparent after the 4-h implants. Probe tracks were surrounded by endothelial cell debris, which appeared as a diffuse halo of PECAM immunoreactivity. The halo intensity decreased with implant duration, indicative of an active wound-healing process. Consistent with this, after 24-h implants, the probe tracks were surrounded by hyperplasic and hypertrophic glia and glial processes were extending towards, and engulfing, the track. Carbon fiber microelectrodes produced a diffuse disruption of nanobead labeling but no focal disruption of blood vessels, no PECAM immunoreactive halo, and no glial activation. These findings illuminate the differences between the extent and nature of the penetration injuries associated with microdialysis and voltammetry.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The implant's size and volume directly correlate with the risk of intracerebral hemorrhage and ischemic injuries.
“The implant’s size and volume directly correlate with the risk of intracerebral hemorrhage and ischemic injuries (Rosidi et al., 2011), with larger implants exerting more pressure, potentially leading to vascular compression and secondary injuries (Jaquins-Gerstl and Michael, 2009; Kozai et al., 2012).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Jaquins-Gerstl and Michael, 2009
The Introduction (page unavailable) says penetration-injury severity and extent are related to penetrator size. The Discussion reports ischemic disruption around microdialysis probes but not comparable focal disruption around carbon-fiber microelectrodes. The paper does not establish the cited clause’s proposed mechanism—that larger implants exert more pressure and compress vessels. The hemorrhage-risk clause is cited to Rosidi et al., not to this paper. (LLM, conf=0.85)
Experimental — accuracy not yet measuredSolutions for balancing power delivery and data transmission can result in compromises such as trade-offs between implant size and power capacity or between energy efficiency and data rate.
“However, these solutions can sometimes result in compromises, such as trade-offs between the size of the implant and its power capacity or between the energy efficiency and the data rate (Santiago and Westerink, 1990; Deboer and Abercrombie, 1996; Jaquins-Gerstl and Michael, 2009; Kozai et al., 2012).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Jaquins-Gerstl and Michael, 2009
The Introduction discusses how probe size relates to brain penetration injury, and the Discussion addresses changes in tissue after implantation. Neither addresses trade-offs between implant size and power capacity or between energy efficiency and data rate; searches for power delivery and data transmission found no relevant passage. (LLM, conf=0.76)
Experimental — accuracy not yet measuredThe inter-relationship between power transfer and data communication in neural implants introduces additional difficulty.
“Furthermore, the inter-relationship between power transfer and data communication in these implants introduces additional layers of difficulty.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Jaquins-Gerstl and Michael, 2009
The Discussion (page unavailable) compares tissue injury from microdialysis probes and carbon-fiber microelectrodes; the Voltammetry Procedures section (page unavailable) describes electrode operation. Neither addresses an inter-relationship between power transfer and data communication in neural implants. Searches for those terms and for wireless power, telemetry, and transmission found no relevant passage. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Cellular and molecular mechanisms of drug dependence
Koob, G. F., & Bloom, F. E. (1988) · Science · doi:10.1126/science.2903550 · Cited by 2,070 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Santiago, M., & Westerink, B. H. C. (1990) · Naunyn-Schmiedeberg's Archives of Pharmacology · doi:10.1007/bf00169457 · Cited by 159 · see citing works
Flagged first, then by citations
Research works printed but not linked: 55
- Benveniste H Diemer NH Cellular reactions to implantation of a microdialysis tube in the rat hippocampus Acta Neuropathologica 1987 74 234 38 3673515
- Benveniste H Drejer J Schousboe A Diemer NH Regional cerebral glucose phosphorylation and blood flow after insertion of a microdialysis fiber through the dorsal hippocampus in the rat J Neurochem 1987 49 729 34 3612121
- Bignami A Dahl D Reuger DC Federoff S Glial fibrillary acidic protein (GFAP) in normal neural cells and in pathological conditions Advances in cellular neurobiology Orlando Academic Press 1980 285 310
- Borland LM Michael AC Voltammetric study of the control of striatal dopamine release by glutamate J Neurochem 2004 91 220 9 15379902
- Borland LM Shi G Yang H Michael AC Voltammetric study of extracellular dopamine near microdialysis probes acutely implanted in the striatum of the anesthetized rat J Neurosci Methods 2005 146 149 58 15975664
- Bungay PM Newton-Vinson P Isele W Garris PA Justice JB Jr Microdialysis of dopamine interpreted with quantitative model incorporation probe implantation trauma J Neurochem 2003 86 932 46 12887691 PMC2386091
- Clapp-Lilly KL Roberts RC Duffy LK Irons KP Hu Y Drew KL An ultrastructural analysis of tissue surrounding a microdialysis probe J Neurosci Methods 1999 90 129 42 10513596
- Cookson MR The biochemistry of Parkinson’s disease Ann Rev Biochem 2005 74 29 52 15952880
- Cragg SJ Rice ME Greenfield SJ Heterogeneity of electrically evoked dopamine release and reuptake in substantia nigra, ventral tegmental area, and striatum J Neurophysiol 1997 77 862 73 9065855
- Cropley VL Fujita M Innis RB Nathan PJ Molecular imaging of the dopaminergic system and its association with human cognition Biol Psychiatry 2006 59 898 907 16682268
- David DJ Zahniser NR Hoffer BJ Gerhardt GA In vivo electrochemical studies of dopamine clearance in subregions of rat nucleus accumbens: differential properties of the core and shell Exp Neurology 1998 153 277 86 9784287
- DeBoer P Abercrombie ED Physiological release of striatal acetylcholine in vivo: modulation by D1 and D2 dopamine receptor subtypes J Pharm Exp Ther 1996 277 775 83 8627558
- Dickinson SD Sabeti J Larson GA Giardina K Rubinstein M Kelley MA Grandy DK Low MJ Gerhardt GA Zahniser NR Dopamine D2 receptor-deficient mice exhibit decreased dopamine transporter function but no changes in dopamine release in dorsal striatum J Neurochem 1999 72 148 56 9886065
- DiChiara G Tanda G Carboni E Estimation of in-vivo neurotransmitter release by brain microdialysis: the issue of validity Behav Pharmacol 1996 7 640 57 11224460
- Dyskstra KH Hsiao JK Morrison PF Bungay PM Mefford IN Scully MM Dedrick RL Quantitative examination of tissue concentration profiles associated with microdialysis J Neurochem 1992 58 931 40 1738000
- Eng LF DeArmond SJ Federoff S Immunohistochemical studies of astrocytes in normal development and disease Advances in cellular neurobiology Academic Press Orlando 1982 145 71
- Garris PA Christensen JRC Rebec GV Wightman RM Real-time measurement of electrically evoked extracellular dopamine in the striatum of freely moving rats J Neurochem 1997 68 152 61 8978721
- Garris PA Ciolkowski EL Wightman RM Heterogeneity of evoked dopamine overflow within the striatal and striatoamygdaloid regions Neurosci 1994 59 417 27 8008199
- Garris PA Kilpatrick M Bunin MA Michael D Walker QD Wightman RM Dissociation of dopamine release in the nucleus accumbens from intracranial self-stimulation Nature 1999 398 67 9 10078530
- Gonon F Prolonged and extrasynaptic excitatory action of dopamine mediated by D1 receptors in the rat striatum in vivo J Neurosci 1997 17 5972 78 9221793 PMC6573191
- Groothius DR Ward S Schlageter KE Itskovish AC Schwerin SC Allen CV Dills C Levy RM Changes in blood-brain barrier permeability associated with insertion of brain cannulas and microdialysis probes Brain Res 1998 803 218 30 9729397
- Groto Y Otani S Grace AA The Yin and Yang of dopamine release: a new perspective Neuropharm 2007 53 583 7 PMC2078202 17709119
- Holson RR Bowyer JF Clausing P Gough B Methamphetamine-stimulated striatal dopamine release declines rapidly over time following microdialysis probe insertion Brain Res 1996 739 301 7 8955951
- Jones SR Gainetdinov RR Caron MG Application of microdialysis and voltammetry to assess dopamine functions in genetically altered mice: correlation with locomotor activity Psychopharm 1999 147 30 2 10591864
- Jones SR Gainetdinov RR Jaber M Giros B Wightman RM Caron MG Profound neuronal plasticity in response to inactivation of the dopamine transporter Proc Natl Acad Sci USA 1998 95 4029 34 9520487 PMC19957
- Kadota E Nonaka K Karasuno M Nishi K Nakamura Y Namikawa K Okazaki YY Teramura K Hashimoto S Experimental quantitative evaluation of transvascular removal of unnecessary substances in brain edema fluid Acta Neurochir Suppl 1994 Suppl 60 162 4 7976534
- Kawagoe KT Zimmerman JB Wightman RM Principles of voltammetry and microelectrode surface states J Neurosci Methods 1993 48 225 40 8412305
- Kulagina NV Zigmond MJ Michael AC Glutamate regulates the spontaneous and evoked release of dopamine in the rat striatum Neuroscience 2001 102 121 8 11226675
- Lu Y Peters JL Michael AC Direct comparison of the response of voltammetry and microdialysis to electrically evoked release of striatal dopamine J Neurochem 1998 70 584 93 9453552
- Major O Shdanova T Duffek L Nagy Z Continuous monitoring of blood-brain barrier opening to 51Cr-EDTA by microdialysis after probe injury Acta Neurochir Suppl 1990 51 46 8 2128582
- Mitala CM Wang Y Borland LM Jung M Shand S Watkins S Weber SG Michael AC Impact of microdialysis probes on vasculature and dopamine in the rat striatum: A combined fluorescence and voltammetry study J Neurosci Methods 2008 174 177 85 18674561 PMC2713687
- Morgan ME Singhal D Anderson BD Quantitative assessment of blood-brain barrier damage during microdialysis J Pharm Exp Ther 1996 277 1167 76 8627529
- Ogura T Ogata M Akita H Jitsuki S Akiba L Noda K Hoka S Saji M Impaired acquisition of skilled behavior in rotarod task by moderate depletion of striatal dopamine in a pre-symptomatic stage model of Parkinson’s disease Neurosci Res 2005 51 299 308 15710494
- Pellegrino LJ Pellegrino AS Cushman AJ A stereotaxic atlas of the rat brain 2 New York Plenum Press 1979
- Peters JL Michael AC Modeling voltammetry and microdialysis of striatal extracellular dopamine: the impact of dopamine uptake on extraction and recovery ratios J Neurochem 1998 70 594 603 9453553
- Peters JL Michael AC Changes in the kinetics of dopamine release and uptake have differential effects on the spatial distribution of extracellular dopamine concentration in the rat striatum J Neurochem 2000 74 1563 73 10737613
- Peters JL Miner LH Michael AC Sesack SR Ultrastructure at carbon fiber microelectrode implantation sites after acute voltammetric measurements in the striatum of anesthetized rats J Neurosci Methods 2004 137 9 23 15196823
- Qian J Wu Y Yang H Michael AC An integrated decoupler for capillary electrophoresis with electrochemical detection: application to analysis of brain microdialysate Anal Chem 1999 71 4486 92 10546530
- Rebec GV Langley PE Pierce CR Wang Z Heidenrich BA A simple micromanipulator for mulipe uses in freely moving rats: electrophysiology, voltammtery and simultaneous intracerebral infusions J Neurosci Methods 1993 47 53 9 8321014
- Salgado-Pineda P Delaveau P Blin O Nieoullon A Dopaminergic contribution to the regulation of emotional perception Clinical Neuropharm 2005 28 228 37 16239763
- Schiffer WK Mirrione MM Biegon A Alexoff DL Patel V Dewey SL Serial microPET measures of the metabolic reaction to microdialysis probe implants J Neurosci Methods 2006 115 272 84 16519945
- Shain W Spataro L Dilgen J Haverstick K Retterer S Isaacson M Saltsman M Turner JN Controlling cellular reactive responses around neural prosthetic devices using peripheral and local intervention strategies IEEE Trans Neural Syst Rehabil Eng 2003 11 186 8 12899270
- Smith AD Justice JB The effect of inhibition of synthesis, release, metabolism and uptake on the microdialysis extraction fraction of dopamine J Neurosci Methods 1994 54 75 82 7815821
- Szarowski DH Anderson MD Retterer S Spence AJ Isaacson M Craighead HG Turner JN Shain W Brain responses to mico-machined silicon devices Brain Res 2003 983 23 35 12914963
- Timmerman W Westerink BHC Brian microdialysis of GABA and glutamate: what does it signify? Synapse 1997 27 242 61 9329159
- Turner JN Shain W Szarowski DN Andersen M Martins S Isaacson M Craighead HG Cerebral astrocyte response to micromachined silicon implants Exp Neurol 1999 156 33 49 10192775
- Wagner AK Sokoloski JE Ren D Chen X Khan AS Zafonte RD Michael AC Dixon CE Controlled cortical impact injury affects dopaminergic transmission in the rat striatum J Neurochem 2005 95 457 65 16190869
- Warden DL Gordon B McAllister TW Silver JM Barth JT Bruns J Drake A Gentry T Katz DI Kraus J Labbate LA Ryan LM Sparling MB Walters B Whyte J Zapata A Zitnay G Guidelines for the pharmacologic treatment of neurobehavioral sequelae of traumatic brain injury J Neurotrauma 2006 23 1468 1501 17020483
- Westerink BHC deVries JB Characterization of in vivo dopamine release as determined by brain microdialysis after acute and subchronic implantations: methodological aspects J Neurochem 1988 51 683 7 3411321
- Westerink BHC Tuntler J Damsma G Rollema H de Vries JB The use of tetrodotoxin for the characterization of drug-enhanced dopamine release in conscious rats studied by brain dialysis Naunyn-Schemiederg’s Arch Pharmacol 1987 336 502 7 3501841
- Wightman RM Heien MLAV Wassum KM Sombers LA Aragona BJ Khan AS Ariansen JL Cheer JL Phillips PE Carelli RM Dopamine release is heterogeneous within microenvironments of the rat nucleus accumbens Eur J Neurosci 2007 26 2046 54 17868375
- Williams GV Castner SA Under the curve: critical issues for elucidating D1 receptor function in working memory Neurosci 2006 139 263 76 16310964
- Yang H Michael AC Michael AC Borland LM In vivo fast-scan cyclic voltammetry of dopamine near microdialysis probes Electrochemical methods for neuroscience CRC Press Boca Raton, FL 2007 489 501 21204386
- Yang H Peters JL Michael AC Coupled effects of mass transfer and uptake kinetics on in vivo microdialysis of dopamine J Neurochem 1998 71 684 92 9681459
- Zhou F Shu X Castellani RJ Stimmelmayr R Perry G Smith MA Drew KL Hibernation, a model of neuroprotection Am J Pathol 2001 158 2145 51 11395392 PMC1891987
Cited by
Sorted by citations
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622 · see citing works
Self-citationA Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389 · see citing works
Taylor, I. M., Robbins, E. M., Catt, K. A., Cody, P. A., Happe, C. L., & Cui, X. T. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.05.084 · Cited by 206 · see citing works
“It is well documented that the introduction of large foreign bodies into healthy neural tissue elicits a substantial immune response localized to the damage site immediately upon penetration (Borland et al. 2005; Jaquins-Gerstl and Michael 2009; Jaquins-Gerstl et al. 2011; Kozai et al. 2015).”
BackgroundRibeiro, J. A., Fernandes, P. M. V., Pereira, C. M. D. M., & Silva, F. (2016) · Talanta · doi:10.1016/j.talanta.2016.06.066 · Cited by 208 · see citing works
Hinzman, J. M., Thomas, T. C., Burmeister, J. J., Quintero, J. E., Huettl, P., Pomerleau, F., Gerhardt, G. A., & Lifshitz, J. (2010) · Journal of Neurotrauma · doi:10.1089/neu.2009.1238 · Cited by 140 · see citing works
“The large sampling area of the microdialysis membrane (1–4 mm in length), and extensive damage from implantation of the microdialysis probe, limit the ability to detect neuronal release (Borland et al., 2005; Jaquins-Gerstl and Michael, 2009).”
Bioengineered sequential growth factor delivery stimulates brain tissue regeneration after stroke
Wang, Y., Cooke, M. J., Sachewsky, N., Morshead, C. M., & Shoichet, M. S. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.07.032 · Cited by 145 · see citing works
“This is a common problem associated with metallic implants in the brain parenchyma [40,41], and can be avoided by using an alternate delivery strategy, such as the epicortical composite.”
BackgroundSchmidt, A. C., Wang, X., Zhu, Y.-T., & Sombers, L. A. (2013) · ACS Nano · doi:10.1021/nn402857u · Cited by 135 · see citing works
Takmakov, P., Zachek, M. K., Keithley, R. B., Bucher, E. S., Mccarty, G. S., & Wightman, R. (2010) · Analytical Chemistry · doi:10.1021/ac102399n · Cited by 125 · see citing works
Deficits in attentional control: Cholinergic mechanisms and circuitry-based treatment approaches.
Sarter, M. F., & Paolone, G. (2011) · Behavioral Neuroscience · doi:10.1037/a0026227 · Cited by 98 · see citing works
“…why microdialysis appears to be optimized for detecting tonic levels of acetylcholine (ACh) that are not contaminated by transients are not fully understood but may be due in part to the formation of a glial-derived diffusion barrier that encapsulated the probe (Jaquins-Gerstl & Michael, 2009).”
BackgroundFEF inactivation with improved optogenetic methods
Acker, L., Pino, E. N., Boyden, E. S., & Desimone, R. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1610784113 · Cited by 95 · see citing works
“Along with reducing penetration damage proportional to diameter, two separate penetrations cause less damage than a single penetration with coupled devices, particularly with 1-mm separation (50, 51) and our illuminator’s increased mechanical compliance vs.”
BackgroundDexamethasone retrodialysis attenuates microglial response to implanted probes in vivo
Kozai, T. D. Y., Jaquins‐Gerstl, A., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.013 · Cited by 106 · see citing works
“the sampling environment around implanted devices [27, 28, 34, 46-48].”
Self-citationHinzman, J., Thomas, T., Quintero, J., Gerhardt, G., & Lifshitz, J. (2012) · Journal of Neurotrauma · doi:10.1089/neu.2011.2261 · Cited by 95 · see citing works
“The extensive damage to the local brain area during implantation of the microdialysis probe and the large area of tissue sampled (1–4 mm in length), restricts microdialysis measurements of glutamate to large regions far beyond synapses (Borland et al., 2005; Hillered et al., 2005; Jaquins-Gerstl and Michael, 2009; Obr…”
BackgroundZachek, M. K., Park, J., Takmakov, P., Wightman, R., & Mccarty, G. S. (2010) · In Analysis · doi:10.1039/c0an00114g · Cited by 94 · see citing works
In Vivo Ambient Serotonin Measurements at Carbon-Fiber Microelectrodes
Abdalla, A., Atcherley, C. W., Pathirathna, P., Samaranayake, S., Qiang, B., Peña, E., Morgan, S. L., Heien, M. L., & Hashemi, P. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01257 · Cited by 92 · see citing works
Keithley, R. B., & Wightman, R. (2011) · ACS Chemical Neuroscience · doi:10.1021/cn200035u · Cited by 91 · see citing works
Taylor, I. M., Patel, N., Freedman, N. C., Castagnola, E., & Cui, X. T. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02904 · Cited by 92 · see citing works
In vivo methods for imaging blood–brain barrier function and dysfunction
Harris, W. J., Asselin, M., Hinz, R., Parkes, L. M., Allan, S. M., Schießl, I., Boutin, H., & Dickie, B. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05997-1 · Cited by 87 · see citing works
Schwerdt, H. N., Zhang, E., Kim, M. J., Yoshida, T., Stanwicks, L. L., Amemori, S., Dağdeviren, H. E., Langer, R., Cima, M. J., & Graybiel, A. M. (2018) · Communications Biology · doi:10.1038/s42003-018-0147-y · Cited by 76 · see citing works
Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications
Hashemi, P., Walsh, P. L., Guillot, T. S., Gras-Najjar, J., Takmakov, P. A., Crews, F. T., & Wightman, R. M. (2011) · ACS Chemical Neuroscience · doi:10.1021/cn2000684 · Cited by 72 · see citing works
Jaquins‐Gerstl, A., Shu, Z., Zhang, J., Liu, Y., Weber, S. G., & Michael, A. C. (2011) · Analytical Chemistry · doi:10.1021/ac200782h · Cited by 73 · see citing works
Self-citationJaquins‐Gerstl, A., & Michael, A. C. (2015) · The Analyst · doi:10.1039/c4an02065k · Cited by 85 · see citing works
Self-citationPharmacological Mitigation of Tissue Damage during Brain Microdialysis
Nesbitt, K. M., Jaquins‐Gerstl, A., Skoda, E. M., Wipf, P., & Michael, A. C. (2013) · Analytical Chemistry · doi:10.1021/ac401201x · Cited by 59 · see citing works
Self-citationHunsberger, H. C., Weitzner, D. S., Rudy, C. C., Hickman, J. E., Libell, E. M., Speer, R. R., Gerhardt, G. A., & Reed, M. N. (2015) · Journal of Neurochemistry · doi:10.1111/jnc.13230 · Cited by 87 · see citing works
Analytical and Biological Methods for Probing the Blood-Brain Barrier
Sloan, C. D. K., Nandi, P., Linz, T. H., Aldrich, J. V., Audus, K. L., & Lunte, S. M. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143002 · Cited by 59 · see citing works
“They found a 200% increase in glia immunoreactive cells 24 h after probe implantation (40).”
BackgroundMethodInfluentialSubcellular probes for neurochemical recording from multiple brain sites
Schwerdt, H. N., Kim, M. J., Amemori, S., Homma, D., Yoshida, T., Shimazu, H., Yerramreddy, H., Karasan, E., Langer, R., Graybiel, A. M., et al. (2017) · Lab on a Chip · doi:10.1039/c6lc01398h · Cited by 64 · see citing works
Receptor-mediated drug delivery of bispecific therapeutic antibodies through the blood-brain barrier
Pardridge, W. M. (2023) · Frontiers in Drug Delivery · doi:10.3389/fddev.2023.1227816 · Cited by 62 · see citing works
“1 micron fluorescent microspheres in parallel with fiber implantation shows the brain capillaries adjacent to the dialysis fiber are not perfused (Jaquins-Gerstl and Michael, 2009).”
InfluentialWang, B., Yang, P., Ding, Y., Qi, H., Gao, Q., & Zhang, C.-X. (2019) · ACS Applied Materials and Interfaces · doi:10.1021/acsami.8b20542 · Cited by 48
Ross, A. E., Nguyen, M. D., Privman, E., & Venton, B. (2014) · Journal of Neurochemistry · doi:10.1111/jnc.12711 · Cited by 47 · see citing works
Wellman, S. M., Cambi, F., & Kozai, T. D. Y. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.08.046 · Cited by 41 · see citing works
“These same activated microglia and astrocytes secrete a multitude of inflammatory cytokines that perpetuate BBB breakdown, further glial cell reactivity, and activate apoptotic signaling cascades in neurons [9].”
InfluentialReal-Time Clinical Monitoring of Biomolecules
Rogers, M. L., & Boutelle, M. G. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073648 · Cited by 46 · see citing works
Dopamine, vocalization, and astrocytes
Turk, A. Z., Marchoubeh, M. L., Fritsch, I., Maguire, G. A., & SheikhBahaei, S. (2021) · Brain and Language · doi:10.1016/j.bandl.2021.104970 · Cited by 44 · see citing works
Aptamer-functionalized neural recording electrodes for the direct measurement of cocaine in vivo
Taylor, I. M., Du, Z. J., Bigelow, E. T., Eles, J. R., Horner, A. R., Catt, K. A., Weber, S. G., Jamieson, B. G., & Cui, X. T. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb00095b · Cited by 53 · see citing works
Next-Generation Diamond Electrodes for Neurochemical Sensing: Challenges and Opportunities
Purcell, E. K., Becker, M., Guo, Y., Hara, S. A., Ludwig, K. A., McKinney, C., Monroe, E., Rechenberg, R., Rusinek, C. A., Saxena, A., et al. (2021) · Micromachines · doi:10.3390/mi12020128 · Cited by 41 · see citing works
“Likewise, microdialysis probes are associated with pronounced glial encapsulation and disruption of blood vessels in comparison to small-diameter carbon fiber microelectrodes (CFMEs) traditionally used for FSCV [57].”
BackgroundDomain‐dependent effects of DAT inhibition in the rat dorsal striatum
Taylor, I. M., Jaquins‐Gerstl, A., Sesack, S. R., & Michael, A. C. (2012) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2012.07774.x · Cited by 40 · see citing works
Self-citationHIV-Associated Apathy/Depression and Neurocognitive Impairments Reflect Persistent Dopamine Deficits
McLaurin, K. A., Harris, M., Madormo, V. A., Harrod, S. B., Mactutus, C. F., & Booze, R. M. (2021) · Cells · doi:10.3390/cells10082158 · Cited by 35 · see citing works
Electrochemical Detection of Dopamine Based on Functionalized Electrodes
Ouellette, M., Mathault, J., Niyonambaza, S. D., Miled, A., & Boisselier, É. (2019) · Coatings · doi:10.3390/coatings9080496 · Cited by 38 · see citing works
“Even if smaller electrodes up to 7 μm induce a much weaker immune response than 200 μm microdialysis probes, their surface is very limited for the detection of neurotransmitters [41,42].”
BackgroundSerotonin in the inferior colliculus fluctuates with behavioral state and environmental stimuli
Hall, I. C., Rebec, G. V., & Hurley, L. M. (2010) · Journal of Experimental Biology · doi:10.1242/jeb.035956 · Cited by 39 · see citing works
Dengler, A. K., & Mccarty, G. S. (2013) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2013.01.022 · Cited by 30
Glutamate transporter control of ambient glutamate levels
Sun, W., Shchepakin, D., Kalachev, L. V., & Kavanaugh, M. P. (2014) · Neurochemistry International · doi:10.1016/j.neuint.2014.04.007 · Cited by 28 · see citing works
Highlights of selected recent electrochemical measurements in living systems
Trouillon, R., Svensson, M. I., Berglund, E. C., Cans, A.-S. U., & Ewing, A. G. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.164 · Cited by 28 · see citing works
Wu, B., Castagnola, E., & Cui, X. T. (2023) · Micromachines · doi:10.3390/mi14020323 · Cited by 26 · see citing works
Microdialysis probes alter presynaptic regulation of dopamine terminals in rat striatum
Wang, Y., & Michael, A. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.04.009 · Cited by 25 · see citing works
“This evidence of a progression of the DA lesion after the implant is consistent with the increased astrogliosis of the probe track at 24 hrs vs. 4 hrs after implantation (Jaquins-Gerstl and Michael, 2009).”
BackgroundResultInfluentialSelf-citationPEDOT/CNT Flexible MEAs Reveal New Insights into the Clock Gene's Role in Dopamine Dynamics
Wu, B., Castagnola, E., McClung, C. A., & Cui, X. T. (2024) · Advanced Science · doi:10.1002/advs.202308212 · Cited by 22 · see citing works
Subsecond detection of guanosine using fast-scan cyclic voltammetry
Cryan, M. T., & Ross, A. E. (2018) · The Analyst · doi:10.1039/c8an01547c · Cited by 42 · see citing works
Biological insights from the direct measurement of purine release.
Dale, N. (2021) · Biochemical Pharmacology · doi:10.1016/j.bcp.2021.114416 · Cited by 23 · see citing works
“Furthermore, the microdialysis probes are quite large and implanted, they become encapsulated by a reactive glial scar [97].”
BackgroundComparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21 · see citing works
Mena, S., Dietsch, S., Berger, S. N., Witt, C. E., & Hashemi, P. (2021) · bioRxiv · doi:10.1021/acsmeasuresciau.1c00003 · Cited by 19
Varner, E. L., Leong, C. L., Jaquins‐Gerstl, A., Nesbitt, K. M., Boutelle, M. G., & Michael, A. C. (2017) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.7b00148 · Cited by 24 · see citing works
Self-citationWu, G.-F., Heck, I., Zhang, N., Phaup, G., Zhang, X.-C., Wu, Y.-X., Stalla, D., Weng, Z.-Y., Sun, H., Li, H.-J., et al. (2022) · Science Advances · doi:10.1126/sciadv.abn2277 · Cited by 15 · see citing works
“Recent studies offer microdialysis probes with a high molecular weight cutoff membrane (16), modified membrane (17), or push pull perfusion systems (18–20) that bypass certain drawbacks associated with the traditional microdialysis probe, but most micro dialysis probes are still constrained by the following: (i) low…”
Background“Letting the little light of mind shine: Advances and future directions in neurochemical detection”
Tjahjono, N., Jin, Y., Hsu, A. C., Roukes, M., & Tian, L. (2021) · Neurosciences research · doi:10.1016/j.neures.2021.11.012 · Cited by 14
“Additionally, a large probe size increases tissue damage leading to ischemia, gliosis, and cell death at the insertion site (Jaquins-Gerstl and Michael, 2009).”
BackgroundLam, D., Javadekar, A., Patil, N. T., Yu, M. H., Li, L., Menendez, D. M., Gupta, A. S., Capadona, J. R., & Shoffstall, A. J. (2022) · SSRN Electronic Journal · doi:10.1016/j.actbio.2023.05.004 · Cited by 11 · see citing works
Wet-spun porous carbon microfibers for enhanced electrochemical detection
Ostertag, B. J., & Ross, A. E. (2023) · ACS Applied Materials and Interfaces · doi:10.1021/acsami.3c00423 · Cited by 13
Using Enzyme-based Biosensors to Measure Tonic and Phasic Glutamate in Alzheimer's Mouse Models.
Hunsberger, H. C., Setti, S., Heslin, R. T., Quintero, J., Gerhardt, G., & Reed, M. N. (2017) · Journal of Visualized Experiments · doi:10.3791/55418 · Cited by 13
Marchoubeh, M. L., Cobb, S., Tello, M. A., Hu, M.-J., Jaquins-Gerstl, A., Robbins, E. M., Macpherson, J., Michael, A., & Fritsch, I. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03327-2 · Cited by 12 · see citing works
“However, penetration injury surrounding a 7-μm diameter carbon fiber electrode is essentially non-detectable [44]), which allows carbon fiber electrodes to be placed in close proximity to dopamine terminals [10].”
BackgroundInfluentialSelf-citationVillarini, N. A., Robins, N., & Ou, Y. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c03093 · Cited by 13 · see citing works
Robbins, E. M., Jaquins‐Gerstl, A., Fine, D. F., Leong, C. L., Dixon, C. E., Wagner, A. K., Boutelle, M. G., & Michael, A. C. (2019) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.9b00145 · Cited by 12 · see citing works
Self-citationTonic and Phasic Amperometric Monitoring of Dopamine Using Microelectrode Arrays in Rat Striatum
Lundblad, M., Price, D. A., Burmeister, J. J., Quintero, J. E., Huettl, P. F., Pomerleau, F., Zahniser, N. R., & Gerhardt, G. A. (2020) · Applied Sciences · doi:10.3390/app10186449 · Cited by 9 · see citing works
“Importantly, smaller sized electrochemical electrodes produce less tissue responsiveness and damage post-implantation in the brain [20,21].”
BackgroundInfluentialSchapira, I., O'Neill, M. R., Russo-Savage, L., Narla, T., Laprade, K. A., Stafford, J. M., & Ou, Y. (2023) · RSC Advances · doi:10.1039/d3ra04551j · Cited by 11 · see citing works
Physiologically Based Pharmacokinetic Model of Brain Delivery of Plasma Protein Bound Drugs
Pardridge, W. (2023) · Pharmaceutical Research · doi:10.1007/s11095-023-03484-2 · Cited by 7 · see citing works
Jaquins‐Gerstl, A., Nesbitt, K. M., & Michael, A. C. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03300-z · Cited by 8 · see citing works
“Tissue fixation, processing, immunochemistry, and fluorescence microscopy followed our published procedures [33, 40, 41].”
MethodSelf-citationDexamethasone-Enhanced Microdialysis and Penetration Injury
Jaquins‐Gerstl, A., & Michael, A. C. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602266 · Cited by 11 · see citing works
Self-citationMayer, S., Saxena, P., Crayen, M. A., & Treue, S. (2025) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2025.110361 · Cited by 4 · see citing works
Li, Y., Huang, Y., Chen, J. J., Hyland, B. I., & Wickens, J. R. (2024) · European Journal of Neuroscience · doi:10.1111/ejn.16269 · Cited by 5 · see citing works
“…analysis after the experiment was not undertaken because electrodes were removed immediately for calibration at the end of the experiment, and this type of carbon fiber electrode does not leave damage tracks (Jaquins-Gerstl & Michael, 2009, 2015; Mitch Taylor et al., 2012; Peters et al., 2004).”
MethodLow-Frequency Oscillations of In Vivo Ambient Extracellular Brain Serotonin
Witt, C. E., Mena, S., Honan, L. E., Batey, L., Salem, V., Ou, Y.-G., & Hashemi, P. (2022) · Cells · doi:10.3390/cells11101719 · Cited by 5 · see citing works
“Electrochemical methods have enabled faster, more localized serotonin measurements by using FSCV at CFMs, with negligible tissue damage [33,34].”
MethodAhn, S., & Phillips, A. (2013) · ACS Chemical Neuroscience · doi:10.1021/cn400040r · Cited by 5 · see citing works
Jaquins‐Gerstl, A., & Michael, A. C. (2013) · Neuromethods · doi:10.1007/978-1-62703-370-1_3 · Cited by 5 · see citing works
Self-citationAnalytical Applications of Membranes
Bruening, M. (2013) · doi:10.1002/9781118522318.emst122 · Cited by 4
Gifford, E. K., Robbins, E. M., Jaquins‐Gerstl, A., Rerick, M. T., Nwachuku, E. L., Weber, S. G., Boutelle, M. G., Okonkwo, D. O., Puccio, A. M., & Michael, A. C. (2021) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.1c00231 · Cited by 5 · see citing works
Self-citationBinnetoğlu, D., Aricioglu, F., Özcan, H., Okkay, U., & Hacımüftüoğlu, A. (2019) · Clinical and Experimental Health Sciences · doi:10.33808/clinexphealthsci.613963 · Cited by 3 · see citing works
“Microdialysis, which is a very important method for the measurement of neurotransmitters, and if allowed to picomolar levels of substances in a sample to be analyzed in 20 minutes is a significant disadvantage (26).”
MethodApplication of Microdialysis for Pharmacokinetics of Traditional Chinese Medicine Studies
Cao, G., Cai, H., Cong, X.-D., Zhang, Y., Shao, Y., & Cai, B. (2009) · doi:10.1080/00032710903201958 · Cited by 3
“The small size of the dialysis probe, nominally 300 mm o.d. with an active window in the range 4–10mm in length, causes minimal perturbation to the tissue (Jaquins-Gerstl and Michael 2009).”
BackgroundColivicchi, M., Stefanini, C., Freinbichler, W., Ballini, C., Bianchi, L., Tipton, K., & della Corte, L. (2013) · Neuromethods · doi:10.1007/978-1-62703-173-8_11 · Cited by 3 · see citing works
Kwon, H., Cho, H.-U., Sim, J., Boo, K.-J., Kang, Y.-M., Hwang, S., Kwak, Y., Jang, J., Kim, K. M., Jeon, S. J., et al. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1579380 · Cited by 1
Mathematical Models of Serotonin, Histamine, and Depression
Best, J., Buchanan, A. M., Nijhout, H., Hashemi, P., & Reed, M. (2021) · Serotonin and the CNS - New Developments in Pharmacology and Therapeutics [Working Title] · doi:10.5772/intechopen.96990 · Cited by 1 · see citing works
“CFMEs have a small probe size (diameter 7 μm) and are biocompatible, creating minimal tissue damage and negligible immune response [48, 49].”
BackgroundChapter 19 Electrochemical Measurement of Neurochemical Concentrations
Bennet, K. E., Blaha, C. D., & Lee, K. H. (2016) · Pan Stanford Publishing eBooks · doi:10.1201/9781315364759-20
Feuerstein, D. (2009) · doi:10.25560/5649 · Cited by 1
“However, a very recent study showed that even at 24 hour post-implantation, signs of ischaemic disruption, though reduced compared to the first four hours, were still evident [341].”
BackgroundMicroelectrodes and nanoelectrodes
Patel, B. (2020) · doi:10.1016/b978-0-12-821203-5.00007-5 · Cited by 1
Mazurkiewicz, W., Linfield, S., Wójtowicz, T., Koprowska, J., & Nery, E. W. (2026) · Electrochimica Acta · doi:10.1016/j.electacta.2026.149002
Bioengineering of novel carbon-based biosensors for real-time biomedical use
Phairatana, T. (2015) · doi:10.25560/58345
Experimental design – challenges in conducting electrochemical measurements for bioanalysis
Patel, B. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-821203-5.00012-9
Effects of Anti-viral Acute Phase Response on Hippocampal Glutamate Regulation
Hunsberger, H. C. (2016) · doi:10.33915/etd.5839
“The large sample 17 area (1-4mm in length) often causes damage and limits the detection of neuronal release (Borland, Shi, Yang, & Michael, 2005; Jaquins-Gerstl & Michael, 2009).”
Glutamate Dysregulation in a TauP301L Mouse Model of Alzheimer's Disease
Hunsberger, H. C. (2014) · doi:10.33915/etd.667
“Damage caused by the large sample area (1–4 mm in length) limited the detection of neuronal release (Borland, Shi, Yang, & Michael, 2005; Jaquins-Gerstl & Michael, 2009), and the low temporal resolution (1–20 min) was inadequate to measure the fast dynamics of glutamate uptake and clearance…”
BackgroundMicrodialysis Probe Requirements
Córcoles, E. P., & Boutelle, M. G. (2013) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-319-00360-3_8
- Authors
- Jaquins-Gerstl, A., & Michael, A. C.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Michael, Adrian C.
- ORCID
- Michael, Adrian C.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 183
- Issue
- 2
- Pages
- 127-135
- ISSN
- 0165-0270 (ISSN-L)
- PMC
- PMC2743756
- OpenAlex
- W2033922262
- Cited by
- 98
- References
- 60
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 6 · 2023: 6 · 2022: 5 · 2021: 11 · 2020: 4 · 2019: 7 · 2018: 3 · 2017: 7 · 2016: 6 · 2015: 2 · 2014: 9 · 2013: 12 · 2012: 8
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- University of Pittsburgh
- National Institutes of Health
- National Institute of Mental Health (#MH075989, R01MH075989)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Keywords
- microdialysis, voltammetry, carbon fiber microelectrodes, extracellular dopamine, striatum, PECAM, glial activation, wound healing, implant duration
- MeSH terms
- Analysis of Variance, Animals, Blood Vessels, Brain Injuries, Corpus Striatum, Disease Models, Animal, Dopamine, Electric Stimulation, Electrodes, Implanted, Glial Fibrillary Acidic Protein, Male, Medial Forebrain Bundle, Time Factors, Wounds, Penetrating, Rats, Sprague-Dawley, Microdialysis, Platelet Endothelial Cell Adhesion Molecule-1, Rats, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review