ReStore: A wireless peripheral nerve stimulation system
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: The growing use of neuromodulation techniques to treat neurological disorders has motivated efforts to improve on the safety and reliability of implantable nerve stimulators. New Method: The present study describes the ReStore system, a miniature, implantable wireless nerve stimulator system that has no battery or leads and is constructed using commercial components and processes. The implant can be programmed wirelessly to deliver charge-balanced, biphasic current pulses of varying amplitudes, pulse widths, frequencies, and train durations. Here, we describe bench and in vivo testing to evaluate the operational performance and efficacy of nerve recruitment. Additionally, we also provide results from a large-animal chronic active stimulation study assessing the long-term biocompatibility of the device. Results: The results show that the system can reliably deliver accurate stimulation pulses through a range of different loads. Tests of nerve recruitment demonstrate that the implant can effectively activate peripheral nerves, even after accelerated aging and post-chronic implantation. Biocompatibility and hermeticity tests provide an initial indication that the implant will be safe for use in humans. Comparison with Existing Method(s): Most commercially available nerve stimulators include a battery and wire leads which often require subsequent surgeries to address failures in these components. Though miniaturized battery-less stimulators have been prototyped in academic labs, they are often constructed using custom components and processes that hinder clinical translation. Conclusions: The results from testing the performance and safety of the ReStore system establish its potential to advance the field of peripheral neuromodulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Upper-Airway Stimulation for Obstructive Sleep Apnea
Strollo, P. J., Soose, R. J., Maurer, J. T., de Vries, N., Cornelius, J., Froymovich, O., Hanson, R. D., Padhya, T. A., Steward, D. L., Gillespie, M. B., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1308659 · Cited by 1,299
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
Eldabe, S., Buchser, E., & Duarte, R. V. (2016) · Pain Medicine · doi:10.1093/pm/pnv025 · Cited by 403 · cited 2×
“Each successive surgery adds cost and puts the patient at risk of complications [13,14].”
BackgroundBION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
High-performance wireless powering for peripheral nerve neuromodulation systems
Tanabe, Y., Ho, J. S., Liu, J., Liao, S.-Y., Zhen, Z., Hsu, S., Shuto, C., Zhu, Z.-Y., Ma, A., Vassos, C., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186698 · Cited by 63
Cited by
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Ultrasound-induced wireless energy harvesting: from materials strategies to functional applications
Jiang, L., Yang, Y., Chen, Y., & Zhou, Q. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105131 · Cited by 131
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“Similarly, the ReStore stimulation system and the endovascular neural stimulators have enabled wireless control of motor units with largely commercial off-the-shelf components, reducing the costs and risks of development [49], [50].”
Metadata
- Authors
- Sivaji, V., Grasse, D. W., Hays, S. A., Bucksot, J. E., Saini, R., Kilgard, M. P., & Rennaker, R. L.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 320
- Pages
- 26-36
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2918211536
- Cited by
- 51
- References
- 7
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.