Finite element analysis: A boon to dentistry
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BIOMECHANICAL AND MOLECULAR REGULATION OF BONE REMODELING
Robling, A. G., Castillo, A. B., & Turner, C. H. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095721 · Cited by 1,343
Application of finite element analysis in implant dentistry: A review of the literature
Geng, J.-P., Tan, K. B. C., & Liu, G.-R. (2001) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.115251 · Cited by 1,106 · cited 1×
“Previously, when FEA was used in dentistry, various simplified assumptions were made regarding modeling geometry, load, boundaries and material properties.(5) Such as-”
MethodBaggi, L., Cappelloni, I., Di Girolamo, M., Maceri, F., & Vairo, G. (2008) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)60259-0 · Cited by 535 · cited 1×
“Several FEA studies postulated that the stress pattern on peri-implant bone is affected by the implant number, dia-meter, length, thread profile, material properties of implant components and also by the quality and quantity of surrounding bone.(11,12) In FEA studies to assess mechanical stress in the periimplant bone…”
MethodModelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504 · cited 1×
“Mostmodels consider isotropic behavior, since it is not possible to quantify the whole anisotropic structure of a bone, organ with current techniques.(8) The load is applied either to the implant or to the bone as required.”
BackgroundApplication of the finite element method in dental implant research
Van Staden, R. C., Guan, H., & Loo, Y. C. (2006) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840600837074 · Cited by 298
O'Mahony, A. M., Williams, J. L., & Spencer, P. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120614.x · Cited by 248 · cited 4×
“The stress distribution in the human mandible at three different life stageswas estimated by Bujt ar et al30 by FEA.”
MethodInfluentialPessoa, R. S. E., Muraru, L., Marcantônio, É., Vaz, L. G., Sloten, J. V., Duyck, J. A. J., & Jaecques, S. (2010) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2009.00155.x · Cited by 180 · cited 1×
“Recently with the advances of digital imaging systems (CT and MRI), it has become possible to extrapolate the individual specific data of bone geometry and property to an FEA model.(6,7) CT and MRI image bone and implant structure at microlevel in three dimensions.”
BackgroundThe structure of the periodontal ligament: an update
Berkovitz, B. K. B. (1990) · European Journal of Orthodontics · doi:10.1093/ejo/12.1.51 · Cited by 147 · cited 1×
“Periodontal ligament (PDL) is a soft highly specialized connective tissue which is located between the tooth root and alveolar bone.(21) Its primary function is tooth support and it is”
BackgroundVairo, G., & Sannino, G. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/250929 · Cited by 102 · cited 1×
“Several FEA studies postulated that the stress pattern on peri-implant bone is affected by the implant number, dia-meter, length, thread profile, material properties of implant components and also by the quality and quantity of surrounding bone.(11,12) In FEA studies to assess mechanical stress in the periimplant bone…”
MethodThe effect of increased crown-to-implant ratio on single-tooth locking-taper implants.
Urdaneta, R. A., Rodriguez, S., McNeil, D. C., Weed, M., & Chuang, S.-K. (2010) · PubMed · Cited by 93
Metadata
- Authors
- Trivedi, S.
- Venue
- Journal of Oral Biology and Craniofacial Research
- Publisher
- Elsevier BV
- Published
- 2014-09
- Volume
- 4
- Issue
- 3
- Pages
- 200-203
- ISSN
- 2212-4268 (ISSN-L)
- OpenAlex
- W2059173757
- Cited by
- 240
- References
- 17
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Finite element analysis: A boon to dentistry. https://app.cochat.ai/papers/10.1016/j.jobcr.2014.11.008
- The paper
- Trivedi, S. (2014). Finite element analysis: A boon to dentistry. Journal of Oral Biology and Craniofacial Research. https://doi.org/10.1016/j.jobcr.2014.11.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.