Dispersive liquid–liquid microextraction combined with capillary electrophoresis and time-of-flight mass spectrometry for urine analysis
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The combination of dispersive liquid-liquid microextraction (DLLME) with capillary electrophoresis (CE) and a time-of-flight mass spectrometer (TOF-MS) was evaluated for the toxicological screening in urine samples. A methodology based on design of experiments (DOE) was implemented to increase the extraction efficiency. Dichloromethane and isopropanol were selected as the extraction and dispersing solvents, respectively. Seven factors for DLLME were screened with the help of a Plackett-Burmann DOE using two model compounds before fine investigation of the important parameters to maximise the compound extraction. These experiments were performed in the CE-UV configuration to overcome potential MS matrix effects. The performance of the entire procedure was then evaluated using CE-ESI-TOF-MS. With a preconcentration factor of more than 130, the highly sensitive DLLME-CE-ESI-TOF-MS method allowed for the detection of 30 toxicological compounds (i.e., amphetamines and their derivatives, opiates, cocaine and its metabolites and pharmaceuticals) in urine with limits of detection in the sub-ng/mL level and was used to analyse real toxicological samples. The combination of DLLME and CE was particularly attractive because of the small amount of organic solvents required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Armenta, S., Garrigues, S., & de la Guardia, M. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.05.003 · Cited by 1,213
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Dispersive liquid-liquid microextraction
Zgoła-Grześkowiak, A., & Grześkowiak, T. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.014 · Cited by 476
Fattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Melwanki, M. B., Chen, W.-S., Bai, H.-Y., Lin, T.-Y., & Fuh, M.-R. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.021 · Cited by 93
Mashayekhi, H. A., Abroomand-Azar, P., Saber-Tehrani, M., & Husain, S. W. (2010) · Chromatographia · doi:10.1365/s10337-009-1456-6 · Cited by 71
Cited by
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Taheri, S., Jalali, F., Fattahi, N., & Bahrami, G. (2015) · Journal of Separation Science · doi:10.1002/jssc.201401115 · Cited by 42
Recent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology
Jiang, Y., He, M.-Y., Zhang, W.-J., Luo, P., Guo, D., Fang, X., & Xu, W. (2017) · Chinese Chemical Letters · doi:10.1016/j.cclet.2017.05.008 · Cited by 30
Metadata
- Authors
- Kohler, I., Schappler, J., Sierro, T., & Rudaz, S.
- Venue
- Journal of Pharmaceutical and Biomedical Analysis
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 73
- Pages
- 82-89
- ISSN
- 0731-7085 (ISSN-L)
- OpenAlex
- W1988886071
- Cited by
- 77
- References
- 8
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dispersive liquid–liquid microextraction combined with capillary electrophoresis and time-of-flight mass spectrometry for urine analysis. https://app.cochat.ai/papers/10.1016/j.jpba.2012.03.036
- The paper
- Kohler, I., Schappler, J., Sierro, T., & Rudaz, S. (2013). Dispersive liquid–liquid microextraction combined with capillary electrophoresis and time-of-flight mass spectrometry for urine analysis. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2012.03.036
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.